Dynamic MDCT of the pancreas: Is time-density curve morphology useful for the differential diagnosis of solid lesions? A preliminary report

被引:17
作者
Zamboni, Giulia A. [1 ]
Bernardin, Livia [1 ]
Mucelli, Roberto Pozzi [1 ]
机构
[1] Policlin GB Rossi, Ist Radiol, I-37134 Verona, Italy
关键词
Pancreas; MDCT; Perfusion; PERFUSION CT; THERAPY;
D O I
10.1016/j.ejrad.2011.11.055
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: CT perfusion has been proposed for pancreatic lesion characterization. However, scan and analysis protocols influence numerical data. To overcome this, the purpose of our study is to evaluate the use of time-density curves obtained from MDCT perfusion of the pancreas for the characterization of normal parenchyma, adenocarcinoma, chronic pancreatitis and endocrine tumors. Methods: 31 patients with solid pancreatic lesions and 21 patients with renal cell carcinoma underwent 64-row MDCT perfusion of the pancreas after injection of 50 cc of a 370 mg I/ml solution at 5 cc/s. 63 time-density curves were obtained from normal parenchyma (21 patients), adenocarcinoma (25), endocrine tumors (4) and atrophic parenchyma (13). Two readers independently categorized the 63 time-density curves into 4 different morphologies: normal wash-in and wash-out (A), low wash-in followed by plateau (B), low wash-in followed by faint wash-out (C) and high wash-in and wash-out (D). Interobserver agreement was calculated with kappa statistics. Fisher test was used to calculate sensitivity, specificity, positive (PPV) and negative (NPV) predictive values for each type of curve. Results: Interobserver agreement was very good (Kappa = 0.849). Curve A had 94.4% sensitivity, 91.1% specificity, 80.95% PPV, 97.6% NPV for 'normal parenchyma'. Curve B had 74.19% sensitivity, 93.75% specificity, 92% PPV, 78.95% NPV in diagnosing 'adenocarcinoma'. Curve C had 45.45% sensitivity, 84.62% specificity, 38.46% PPV, 88% NPV for 'chronic pancreatitis'. Curve D had 100% sensitivity, 98.33% specificity, 75% PPV, 100% NPV for 'endocrine tumor'. Conclusions: The morphology of MDCT perfusion time-density curves appears to be useful in characterizing pancreatic lesions, and might help overcome the differences in scan and postprocessing techniques. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E381 / E385
页数:5
相关论文
共 13 条
[1]   Pancreatic Endocrine Tumors: Tumor Blood Flow Assessed with Perfusion CT Reflects Angiogenesis and Correlates with Prognostic Factors [J].
d'Assignies, Gaspard ;
Couvelard, Anne ;
Bahrami, Stephane ;
Vullierme, Marie-Pierre ;
Hammel, Pascal ;
Hentic, Olivia ;
Sauvanet, Alain ;
Bedossa, Pierre ;
Ruszniewski, Philippe ;
Vilgrain, Valerie .
RADIOLOGY, 2009, 250 (02) :407-416
[2]   Functional imaging in CT [J].
Dawson, Peter .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (03) :331-340
[3]   Effect of Temporal Interval Between Scan Acquisitions on Quantitative Vascular Parameters in Colorectal Cancer: Implications for Helical Volumetric Perfusion CT Techniques [J].
Goh, Vicky ;
Liaw, Jonathan ;
Bartram, Clive I. ;
Halligan, Steve .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (06) :W288-W292
[4]   Quantitative tumor perfusion assessment with multidetector CT: Are measurements from two commercial software packages interchangeable? [J].
Goh, Vicky ;
Halligan, Steve ;
Bartram, Clive I. .
RADIOLOGY, 2007, 242 (03) :777-782
[5]   Whole-organ perfusion of the pancreas using dynamic volume CT in patients with primary pancreas carcinoma: acquisition technique, post-processing and initial results [J].
Kandel, Sonja ;
Kloeters, Christian ;
Meyer, Henning ;
Hein, Patrick ;
Hilbig, Andreas ;
Rogalla, Patrik .
EUROPEAN RADIOLOGY, 2009, 19 (11) :2641-2646
[6]   Dynamic breast MR imaging: Are signal intensity time course data useful for differential diagnosis of enhancing lesions? [J].
Kuhl, CK ;
Mielcareck, P ;
Klaschik, S ;
Leutner, C ;
Wardelmann, E ;
Gieseke, J ;
Schild, HH .
RADIOLOGY, 1999, 211 (01) :101-110
[7]   The use of perfusion CT for the evaluation of therapy combining AZD2171 with gefitinib in cancer patients [J].
Meijerink, Martijn R. ;
Van Cruijsen, Hester ;
Hoekman, Klaas ;
Kater, Matthijs ;
van Schaik, Cors ;
van Waesberghe, Jan Hein T. M. ;
Giaccone, Giuseppe ;
Manoliu, Radu A. .
EUROPEAN RADIOLOGY, 2007, 17 (07) :1700-1713
[8]   MEASUREMENT OF HUMAN PANCREATIC PERFUSION USING DYNAMIC COMPUTED-TOMOGRAPHY WITH PERFUSION IMAGING [J].
MILES, KA ;
HAYBALL, MP ;
DIXON, AK .
BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (809) :471-475
[9]   CT perfusion in solid-body tumours. Part I: technical issues [J].
Petralia, G. ;
Preda, L. ;
D'Andrea, G. ;
Viotti, S. ;
Bonello, L. ;
De Filippi, R. ;
Bellomi, M. .
RADIOLOGIA MEDICA, 2010, 115 (06) :843-857
[10]   Perfusion MDCT enables early detection of therapeutic response to antiangiogenic therapy [J].
Sabir, Adeel ;
Schor-Bardach, Rachel ;
Wilcox, Carol J. ;
Rahmanuddin, Syed ;
Atkins, Michael B. ;
Kruskal, Jonathan B. ;
Signoretti, Sabina ;
Raptopoulos, Vassilios D. ;
Goldberg, S. Nahum .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (01) :133-139