Investigation of a booster secondary reflector for a parabolic trough solar collector

被引:35
作者
Bellos, Evangelos [1 ]
Tzivanidis, Christos [1 ]
机构
[1] Natl Tech Univ Athens, Sch Mech Engn, Thermal Dept, Heroon Polytech 9, Athens 15780, Greece
关键词
Optical enhancement; Booster reflector; Optical optimization; Yearly enhancement; MULTILEVEL ANALYTICAL METHODOLOGY; DIRECT STEAM-GENERATION; THERMAL PERFORMANCE; HEAT-TRANSFER; THERMODYNAMIC PERFORMANCE; RECEIVER; NANOFLUIDS; ENHANCEMENT; VALIDATION; EFFICIENCY;
D O I
10.1016/j.solener.2018.12.071
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The objective of this work is the investigation of a novel booster reflector in a parabolic trough collector (PTC). More specifically, a vertical secondary booster reflector is located at the end of the trough in order to enhance the optical performance of the solar collector. This extra concentrator reduces the end optical losses of the PTC by reflecting back them in the receiver. Moreover, it acts as an extra reflecting area which captures extra solar beam irradiation in the cases with a non-zero incident angle. The collector is examined optically and thermally in order to determine both the optical and the thermal gain by the use of this novel idea. The overall analysis is conducted for steady-state conditions, as well as the yearly evaluation of the suggested idea is given. According to the final results, the use of the extra booster leads always to optical and thermal enhancement, especially in greater incident angles. The yearly optical enhancement, for a collector with a focal distance to length ratio of 0.236, is calculated at 21.7% and it is more intense in the months with greater incident angles. More specifically, it was calculated at 8.7% in June, 24.2% in September and 77.1% in December. The thermal analysis proved that the thermal enhancement is greater than the optical and it is higher when the system operates with great fluid temperature levels.
引用
收藏
页码:174 / 185
页数:12
相关论文
共 48 条
[21]   INCIDENCE-ANGLE MODIFIER AND AVERAGE OPTICAL-EFFICIENCY OF PARABOLIC TROUGH COLLECTORS [J].
GAUL, H ;
RABL, A .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1980, 102 (01) :16-21
[22]   Numerical thermal study on effect of porous rings on performance of solar parabolic trough collector [J].
Ghasemi, Seyed Ebrahim ;
Ranjbar, Ali Akbar .
APPLIED THERMAL ENGINEERING, 2017, 118 :807-816
[23]   Performance evaluation and nanofluid using capability study of a solar parabolic trough collector [J].
Kasaeian, Alibakhsh ;
Daviran, Samaneh ;
Azarian, Reza Danesh ;
Rashidi, Alimorad .
ENERGY CONVERSION AND MANAGEMENT, 2015, 89 :368-375
[24]   Thermal load and bending analysis of heat collection element of direct-steam-generation parabolic-trough solar power plant [J].
Li, Lu ;
Sun, Jie ;
Li, Yinshi .
APPLIED THERMAL ENGINEERING, 2017, 127 :1530-1542
[25]   Prospective fully-coupled multi-level analytical methodology for concentrated solar power plants: General modelling [J].
Li, Lu ;
Sun, Jie ;
Li, Yinshi .
APPLIED THERMAL ENGINEERING, 2017, 118 :171-187
[26]   Prospective fully-coupled multi-level analytical methodology for concentrated solar power plants: Applications [J].
Li, Lu ;
Li, Yinshi ;
Sun, Jie .
APPLIED THERMAL ENGINEERING, 2017, 118 :159-170
[27]   A Monte Carlo method and finite volume method coupled optical simulation method for parabolic trough solar collectors [J].
Liang, Hongbo ;
Fan, Man ;
You, Shijun ;
Zheng, Wandong ;
Zhang, Huan ;
Ye, Tianzhen ;
Zheng, Xuejing .
APPLIED ENERGY, 2017, 201 :60-68
[28]   Optimizing the efficiency of a solar receiver with tubular cylindrical cavity for a solar-powered organic Rankine cycle [J].
Loni, R. ;
Kasaeian, A. B. ;
Asli-Ardeh, E. Askari ;
Ghobadian, B. .
ENERGY, 2016, 112 :1259-1272
[29]   An investigation on a compound cylindrical solar concentrator (CCSC) [J].
Ma, Xinglong ;
Zheng, Hongfei ;
Chen, Zhili .
APPLIED THERMAL ENGINEERING, 2017, 120 :719-727
[30]   Analysis of internal helically finned tubes for parabolic trough design by CFD tools [J].
Munoz, Javier ;
Abanades, Alberto .
APPLIED ENERGY, 2011, 88 (11) :4139-4149