PEEK Maxillary Obturator Prosthesis Fabrication Using Intraoral Scanning, 3D Printing, and CAD/CAM

被引:3
作者
Tasopoulos, Theodoros
Chatziemmanouil, Dimitrios
Kouveliotis, George
Karaiskou, Georgia
Wang, Joy [1 ]
Zoidis, Panagiotis [1 ]
机构
[1] Univ Florida, Coll Dent, Dept Restorat Dent Sci, Div Prosthodont, Gainesville, FL USA
关键词
CONVENTIONAL IMPRESSIONS; POLYETHERETHERKETONE; FRAMEWORK; PATIENT;
D O I
10.71607/ijp.6575
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This report presents a digital technique for the fabrication of a two-piece hollow bulb maxillary obturator prosthesis. The procedure described resulted in an accurate prosthesis while avoiding the discomfort associated with analog impressions. The manipulation of a routine postoperative CT scan in conjunction with a 3D printer allowed for the fabrication of a 3D-printed anatomical cast, from which the two-piece hollow bulb obturator was fabricated. The obturator prosthesis framework was digitally designed and milled from a modified PEEK material, resulting in a lightweight prosthesis with excellent biocompatibility. The clinical and laboratory steps involved are described.
引用
收藏
页码:333 / 340
页数:8
相关论文
共 16 条
[1]  
[Anonymous], QUINTESSENCE J DENT
[2]   BASIC PRINCIPLES OF OBTURATOR DESIGN FOR PARTIALLY EDENTULOUS PATIENTS .1. CLASSIFICATION [J].
ARAMANY, MA .
JOURNAL OF PROSTHETIC DENTISTRY, 1978, 40 (05) :554-557
[3]  
Chochlidakis KM, 2016, J PROSTHET DENT, V116, P184, DOI 10.1016/j.prosdent.2015.12.017
[4]   USE OF POLYETHERETHERKETONE IN THE FABRICATION OF A MAXILLARY OBTURATOR PROSTHESIS: A CLINICAL REPORT [J].
Costa-Palau, Santiago ;
Torrents-Nicolas, Josep ;
Brufau-de Barbera, Magi ;
Cabratosa-Termes, Josep .
JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (03) :680-682
[5]   Patient outcomes and procedure working time for digital versus conventional impressions: A systematic review [J].
Gallardo, Yolanda R. ;
Bohner, Lauren ;
Tortamano, Pedro ;
Pigozzo, Monica N. ;
Lagana, Dalva C. ;
Sesma, Newton .
JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (02) :214-219
[6]   GAGGING - A CHAIRSIDE APPROACH TO CONTROL [J].
HOADREDDICK, G .
BRITISH DENTAL JOURNAL, 1986, 161 (05) :174-176
[7]   INTRAORAL SCANNING OF HARD AND SOFT TISSUES FOR PARTIAL REMOVABLE DENTAL PROSTHESIS FABRICATION [J].
Kattadiyil, Mathew T. ;
Mursic, Zachary ;
AlRumaih, Hamad ;
Goodacre, Charles J. .
JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (03) :444-448
[8]   Polyetheretherketone - cytotoxicity and mutagenicity in vitro [J].
Katzer, A ;
Marquardt, H ;
Westendorf, J ;
Wening, JV ;
von Foerster, G .
BIOMATERIALS, 2002, 23 (08) :1749-1759
[9]   Fabricating an Obturator Using Rapid Prototyping to Design the Framework: A Case Report [J].
Kim, Min-Soo ;
Lee, Jeong-Yol ;
Shin, Sang-Wan .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2014, 27 (05) :439-441
[10]   Fabrication of a definitive obturator from a 3D cast with a chairside digital scanner for a patient with severe gag reflex: A clinical report [J].
Londono, Jimmy ;
Abreu, Amara ;
Baker, Philip S. ;
Furness, Alan R. .
JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (05) :735-738