Demonstration that methadone is being present in the exhaled breath aerosol fraction

被引:28
作者
Beck, Olof [1 ]
Sandqvist, Soren [1 ]
Franck, Johan [2 ]
机构
[1] Karolinska Inst, Dept Med, Clin Pharmacol Sect, Stockholm, Sweden
[2] Karolinska Inst, Dept Clin Neurosci, Div Psychiat, Stockholm, Sweden
基金
瑞典研究理事会;
关键词
Abused drug testing; Liquid chromatography-mass spectrometry; Methadone; Exhaled breath; Bioaerosol; LEUKOTRIENE B-4; MASS-SPECTROMETRY; CONDENSATE; VALIDATION; PARTICLES; AIR;
D O I
10.1016/j.jpba.2011.08.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Methadone has previously been found present in exhaled breath of methadone treated patients. This study aimed at studying if methadone is present in the aerosol fraction of exhaled breath and used different filter sampling techniques for that. Patients receiving methadone maintenance treatment were recruited for the study. Methadone was extracted from filters collecting methadone from exhaled breath using 2-propanol, methanol and ethyl acetate and measured using liquid-chromatography-tandem mass-spectrometry. The limit of quantification was 5 pg/sample and the intra-day imprecision and accuracy within 15%. The recovery of extracting methadone from filters was >90%. Two types of micro-particle filters were used in this study and were compared with the C18 silica filter (Empore) used before. The Glass fiber filter collected methadone from exhaled breath of methadone patients. The amount collected significantly exceeded the amount using the C18 Empore filter (3.6-14-fold), but the variability of amount trapped was large. The second filter type was a polymer filter. Also this filter was able to trap methadone from exhaled breath of methadone patients. The amount and variability was similar to the C18 Empore filter but smaller than the Glass fiber filter. The mean rate of methadone excretion measured with the best polymer filter was 92 pg/min with a range between 20 and 287 (n = 5). The polymer filter has the practical advantage of having a low flow resistance making it possible to sample without pumping assistance. The polymer filter was found to collect >90% of the exhaled methadone. The conclusion of this study was that methadone in exhaled breath is carried in the aerosol fraction known to be formed in the lung as a result of normal breathing. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1024 / 1028
页数:5
相关论文
共 21 条
[1]   Effect of airway opening on production of exhaled particles [J].
Almstrand, Ann-Charlotte ;
Bake, Bjorn ;
Ljungstrom, Evert ;
Larsson, Per ;
Bredberg, Anna ;
Mirgorodskaya, Ekaterina ;
Olin, Anna-Carin .
JOURNAL OF APPLIED PHYSIOLOGY, 2010, 108 (03) :584-588
[2]   Airway Monitoring by Collection and Mass Spectrometric Analysis of Exhaled Particles [J].
Almstrand, Ann-Charlotte ;
Ljungstrom, Evert ;
Lausmaa, Jukka ;
Bake, Bjorn ;
Sjovall, Peter ;
Olin, Anna-Carin .
ANALYTICAL CHEMISTRY, 2009, 81 (02) :662-668
[3]   Aerosol loading performance of electret filter media [J].
Barrett, LW ;
Rousseau, AD .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1998, 59 (08) :532-539
[4]  
BECK O, J ANAL TOXI IN PRESS
[5]   Study on the Sampling of Methadone from Exhaled Breath [J].
Beck, Olof ;
Sandqvist, Soren ;
Boettcher, Michael ;
Eriksen, Paul ;
Franck, Johan ;
Palmskog, Goran .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2011, 35 (05) :257-263
[6]   Determination of Methadone in Exhaled Breath Condensate by Liquid Chromatography-Tandem Mass Spectrometry [J].
Beck, Olof ;
Sandqvist, Soren ;
Eriksen, Paul ;
Franck, Johan ;
Palmskog, Goran .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2011, 35 (03) :129-133
[7]   Method for determination of methadone in exhaled breath collected from subjects undergoing methadone maintenance treatment [J].
Beck, Olof ;
Sandqvist, Soeren ;
Eriksen, Paul ;
Franck, Johan ;
Palmskog, Goeran .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (24) :2255-2259
[8]   Amphetamines Detected in Exhaled Breath from Drug Addicts: A New Possible Method for Drugs-of-Abuse Testing [J].
Beck, Olof ;
Leine, Kathinka ;
Palmskog, Goran ;
Franck, Johan .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2010, 34 (05) :233-237
[9]   Human exhaled air analytics: Biomarkers of diseases [J].
Buszewski, Boguslaw ;
Kesy, Martyna ;
Ligor, Tomasz ;
Amann, Anton .
BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (06) :553-566
[10]   Exhaled breath condensate isoprostanes are elevated in patients with acute lung injury or ARDS [J].
Carpenter, CT ;
Price, PV ;
Christman, BW .
CHEST, 1998, 114 (06) :1653-1659