Estimation of minoxidil in human plasma using UHPLC-MS/MS and its application in pharmacokinetic study

被引:4
作者
Basuri, P. Poorna [1 ]
Vijayakumar, R. [1 ]
机构
[1] CL Baid Metha Coll Pharm, Dept Pharmaceut Anal, Chennai 600097, India
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2022年 / 1192卷
关键词
Bioanalysis; Minoxidil; LC-MS; MS; LLE; BA; BE studies; PERFORMANCE LIQUID-CHROMATOGRAPHY;
D O I
10.1016/j.jchromb.2022.123104
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Measurement of drug concentration in biological matrices (such as serum, plasma, blood, urine, and saliva) is important to determine Bioavailability (BA) and/or Bioequivalence (BE) of a drug product which are required during the drug product development and approval process to support applications for new active substances (INDs, NDAs) and generic (ANDAs) drug products to make critical decisions on safety and efficacy. Because of their vital role, bioanalytical methods should be well-characterized, fully validated and documented to yield reliable results. In present work, a simple, specific, high throughput, accurate and sensitive UHPLC-MS/MS method has been developed and validated for quantification of Minoxidil in human plasma. The analyte and the internal standard were extracted from plasma by Liquid-Liquid Extraction using ethyl acetate. The chromatographic separation was achieved on Thermo Hypersil Gold column (4.6x50mm, 5 mu m) using acetonitrile-0.1% formic acid in water (60:40, v/v) at a flow rate of 0.400 ml/min. Detection by turbospray positive ionization mass spectrometry in the multiple reaction monitoring mode with a mass transition ion-pair of m/z 210.152-* 163.965 (Minoxidil) and m/z 220.267-* 169.089 (Internal Standard-Minoxidil D10) was found to be linear over the concentration range of 1.280 to 151.075 ng/ml. The method was fully validated as per USFDA guidelines and the results were within regulatory limits. The inter and intra-day precision ranged from 5.42 to 9.27% and 2.55-9.42% respectively. The inter and intra-day accuracy ranged from 89.2 to 98.9% and 102-105% respectively. The method was successfully applied to a BE study involving human volunteers.
引用
收藏
页数:7
相关论文
共 13 条
[1]   DETERMINATION OF MINOXIDIL IN BULK DRUG AND PHARMACEUTICAL FORMULATIONS BY ION-PAIRING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ASMUS, PA ;
LANDIS, JB ;
GRANT, ME ;
HAVEL, HA .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1984, 73 (09) :1290-1293
[2]   MINOXIDIL ANALYSIS IN HUMAN-PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION - APPLICATION TO PHARMACOKINETIC STUDIES [J].
CARRUM, G ;
ABERNETHY, DR ;
SADHUKHAN, M ;
WRIGHT, CE .
JOURNAL OF CHROMATOGRAPHY, 1986, 381 (01) :127-135
[3]  
European Medical Agency, 2015, ASEAN guideline for the conduct of bioequivalence studies
[4]  
Fda & Cder, BIOAN METH VAL GUID
[5]  
FDA & CDER, 2015, LON MIN TABL
[6]   THE DETERMINATION OF MINOXIDIL IN HUMAN-SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH AMPEROMETRIC DETECTION [J].
GOLDEN, MH ;
ZOUTENDAM, PH .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1987, 5 (06) :543-551
[7]  
Grebe Stefan Kg, 2011, Clin Biochem Rev, V32, P5
[8]  
Indian Council of Medical Research, 2006, ETH GUID BIOM RES
[9]  
Sridevi S., 2020, Res J Pharm Technol, V13, P1913, DOI [10.5958/0974-360X.2020.00344.3, DOI 10.5958/0974-360X.2020.00344.3]
[10]   Advantages of LC-MS-MS compared to LC-MS for the determination of nitrofuran residues in honey [J].
Tribalat, Laure ;
Paisse, Olivier ;
Dessalces, Guy ;
Grenier-Loustalot, Marie-Florence .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (7-8) :2161-2168