A data acquisition system for parallel readout of delay line detectors based on space-time-space conversion

被引:3
|
作者
Mio, H
Chemloul, M
Laggner, P
Islei, CD
Krummenacher, F
Gabriel, A
Koch, MHJ
机构
[1] DESY, European Mol Biol Lab, Hamburg Outstn, D-22603 Hamburg, Germany
[2] Osterreich Akad Wissensch, Inst Biophys & Rontgenstrukturforsch, A-8010 Graz, Austria
[3] Smart Silicon Syst, CH-1007 Lausanne, Switzerland
[4] ILL, European Mol Biol Lab, Grenoble Outstn, F-38042 Grenoble 9, France
关键词
ASIC; synchrotron radiation; position-sensitive detector;
D O I
10.1016/S0168-9002(98)00869-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
First tests of a data acquisition system for linear position-sensitive gas proportional detectors based on an ASIC (application specific integrated circuit) implementing the space-time-space conversion method for parallel readout of delay lines are presented. Using a standard delay line detector a spatial resolution of 0.3 mm/channel was achieved corresponding to a time resolution of congruent to 0.4 ns/channel in the ASIC. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:715 / 720
页数:6
相关论文
共 50 条
  • [1] Data acquisition system for parallel readout of delay line detectors based on space-time-space conversion
    Mio, H.
    Chemloul, M.
    Laggner, P.
    de Raad Iseli, C.
    Krummenacher, F.
    Gabriel, A.
    Koch, M.H.J.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 419 (2-3): : 715 - 720
  • [2] A data acquisition system for gas proportional detectors with delay line readout based on space-time-space conversion
    Iseli, CD
    Reimann, T
    Golding, F
    Boulin, C
    Epstein, A
    Beloeuvre, E
    Gabriel, A
    Koch, MHJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 1152 - 1155
  • [3] PARALLEL READOUT OF X-RAY-DETECTORS USING DELAY-LINES - SPACE-TIME SPACE CONVERSION
    GABRIEL, A
    KOCH, MHJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 313 (03): : 549 - 554
  • [4] A self contained Linux based data acquisition system for 2D detectors with delay line readout
    Beltran, D.
    Toledo, J.
    Klora, A. C.
    Ramos-Lerate, I.
    Martinez, J. C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 570 (03): : 511 - 517
  • [5] A versatile data acquisition system for time resolved X-ray scattering using gas proportional detectors with delay line readout
    Shang, W
    Robrahn, B
    Golding, F
    Koch, MHJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 530 (03): : 513 - 520
  • [6] Parallel readout electronics and data acquisition for SSPM-based PET detectors
    Sun, Xishan
    Shao, Yiping
    Lan, Kejian
    Bircher, Chad
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [7] Data Acquisition and Processing Module with a Network Interface for MWPC Detectors with Delay-Line Readout
    M. A. Golubev
    T. V. Saveleva
    O. N. Gapon
    M. R. Kolkhidashvili
    A. O. Polyushkin
    V. A. Solovei
    Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques, 2022, 16 : 1023 - 1028
  • [8] Data Acquisition and Processing Module with a Network Interface for MWPC Detectors with Delay-Line Readout
    Golubev, M. A.
    Saveleva, T., V
    Gapon, O. N.
    Kolkhidashvili, M. R.
    Polyushkin, A. O.
    Solovei, V. A.
    JOURNAL OF SURFACE INVESTIGATION, 2022, 16 (06): : 1023 - 1028
  • [9] A data acquisition system for two-dimensional position sensitive micropattern gas detectors with delay-line readout
    Hanu, A. R.
    Prestwich, W. V.
    Byun, S. H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 780 : 33 - 39
  • [10] DIRECT TIME DIGITIZING FOR DETECTORS WITH DELAY-LINE READOUT
    BOULIN, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 201 (01): : 237 - 239