Durability and outcome of endoscopic ultrasound-guided hepaticoduodenostomy using a fully covered metal stent for segregated right intrahepatic duct dilatation

被引:21
|
作者
Ma, Ka Wing [1 ]
So, Hoonsub [2 ]
Cho, Dong Hui [3 ]
Oh, Jin Sun [2 ]
Cheung, Tan To [1 ]
Park, Do Hyun [2 ]
机构
[1] Univ Hong Kong, Dept Surg, Hong Kong, Peoples R China
[2] Univ Ulsan, Asan Med Ctr, Div Gastroenterol, Dept Internal Med,Coll Med, 88 Olymp Ro 43 Gil, Seoul 05505, South Korea
[3] Chung Ang Univ, Dept Internal Med, Hyundae Gen Hosp, Div Gastroenterol, Namyangju, South Korea
关键词
cholangiocarcinoma; endoscopic ultrasound; imaging and advanced technology; applied therapeutics; BILIARY DRAINAGE; ADVERSE EVENTS; HEPATICOGASTROSTOMY; ANASTOMOSIS; CARCINOMA;
D O I
10.1111/jgh.15089
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims Segregated right intrahepatic duct dilatation (IHD) results from complete obstruction of the biliary tract proximal to the hilar level. We aimed to evaluate long-term efficacy and safety of endoscopic ultrasound (EUS) hepaticoduodenostomy (HDS) in segregated right IHD. Methods Consecutive patients who had undergone EUS-guided HDS with a fully covered self-expandable metal stent (FCSEMS) in an academic tertiary center were recruited. All patients had segregated right hepatic duct and failed drainage by endoscopic retrograde cholangiopancreatography (ERCP). Demographic data, endoscopic findings, procedure details, and outcome data were extracted from a prospectively maintained database. Results From 2013 to 2017, there were 35 patients who had undergone EUS-guided HDS with a median follow-up duration of 169 (3-2091) days. Malignancy accounted for 71.4% of the ductal segregation, followed by surgical complication (17.1%). Technical and clinical success rate was 97.1% and 80%, respectively. Early adverse event (AE) happened in seven patients (20%), two of them required endoscopic reintervention, and no percutaneous transhepatic biliary drainage (PTBD) or surgery was performed because of AE. The median stent patency duration was 331 (3-1202) days. The median duration of fistula tract keeping was 1280 (3-1280) days. There was no significant difference in terms of patency rate with respect to whether the underlying pathology was benign or malignant (P = 0.776). EUS-guided HDS for right posterior sectional duct segregation was associated with higher 3-month stent patency rate when compared with right anterior sectional duct (79.1% vs 38.1%, P = 0.012). Conclusion Endoscopic ultrasound-guided HDS with an FCSEMS appears to be a safe and effective treatment as a viable alternative option to PTBD after failed ERCP. It creates a durable and reliable fistula tract for permanent access to an isolated ductal system, and this application deserves more attention.
引用
收藏
页码:1753 / 1760
页数:8
相关论文
共 50 条
  • [21] Re-intervention Utility After Endoscopic Ultrasound-Guided Hepaticogastrostomy Using a Partially Covered Stent with Anchoring Flange
    Shin, Il Sang
    Moon, Jong Ho
    Lee, Yun Nah
    Park, Jae Woo
    Lee, Tae Hoon
    Yang, Jae Kook
    Cho, Young Deok
    Park, Sang-Heum
    DIGESTIVE DISEASES AND SCIENCES, 2025, 70 (03) : 1116 - 1125
  • [22] Efficacy of the 6-mm fully covered self-expandable metal stent during endoscopic ultrasound-guided hepaticogastrostomy as a primary biliary drainage for the cases estimated difficult endoscopic retrograde cholangiopancreatography: A prospective clinical study
    Okuno, Nozomi
    Hara, Kazuo
    Mizuno, Nobumasa
    Kuwahara, Takamichi
    Iwaya, Hiromichi
    Ito, Ayako
    Kuraoka, Naosuke
    Matsumoto, Shimpei
    Polmanee, Petcharee
    Niwa, Yasumasa
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2018, 33 (07) : 1413 - 1421
  • [23] Endoscopic ultrasound-assisted cholecystogastrostomy by a novel fully covered metal stent for the treatment of gallbladder stones
    Ge, Nan
    Wang, Shupeng
    Wang, Sheng
    Wang, Guoxin
    Liu, Xiang
    Guo, Jintao
    Yang, Fei
    Liu, Wen
    Sun, Siyu
    ENDOSCOPIC ULTRASOUND, 2015, 4 (02) : 152 - 155
  • [24] Endoscopic ultrasound-guided cholecystostomy for resection of gallbladder polyps with lumen-apposing metal stent
    Shen, Yonghua
    Cao, Jun
    Zhou, Xiaoliang
    Zhang, Song
    Li, Juan
    Xu, Guifang
    Zou, Xiaoping
    Lu, Ying
    Yao, Yuling
    Wang, Lei
    MEDICINE, 2020, 99 (43)
  • [25] Endoscopic Ultrasound-guided Antegrade Stenting in an Occluded Biliary Self-expandable Metal Stent
    Almadi, Majid A.
    Eltayeb, Mohanned
    Thaniah, Salem
    SAUDI JOURNAL OF GASTROENTEROLOGY, 2016, 22 (04) : 337 - 340
  • [26] Initial experience of endoscopic ultrasound-guided antegrade covered stent placement with long duodenal extension for malignant distal biliary obstruction (with video)
    So, Hoonsub
    Oh, Dongwook
    Takenaka, Mamoru
    Minaga, Kosuke
    Uemura, Shinya
    Iwashita, Takuji
    Saito, Tomotaka
    Nakai, Yousuke
    Kim, Seon Ok
    Park, Do Hyun
    JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES, 2021, 28 (12) : 1130 - 1137
  • [27] Feasibility and safety of endoscopic ultrasound-guided gallbladder drainage using a newly designed lumen-apposing metal stent
    Cho, Dong Hui
    Jo, Seok Jung
    Lee, Jae Hoon
    Song, Tae Jun
    Park, Do Hyun
    Lee, Sung Koo
    Kim, Myung-Hwan
    Lee, Sang Soo
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2019, 33 (07): : 2135 - 2141
  • [28] Feasibility and safety of endoscopic ultrasound-guided gallbladder drainage using a newly designed lumen-apposing metal stent
    Dong Hui Cho
    Seok Jung Jo
    Jae Hoon Lee
    Tae Jun Song
    Do Hyun Park
    Sung Koo Lee
    Myung-Hwan Kim
    Sang Soo Lee
    Surgical Endoscopy, 2019, 33 : 2135 - 2141
  • [29] Expanding indications for endoscopic ultrasound-guided hepaticogastrostomy for patients with insufficient dilatation of the intrahepatic bile duct using a 22G needle combined with a novel 0.018-inch guidewire (with video)
    Ogura, Takeshi
    Ueno, Saori
    Okuda, Atsushi
    Nishioka, Nobu
    Yamada, Masanori
    Ueshima, Kazuya
    Matsuno, Jun
    Yamamoto, Yoshitaro
    Higuchi, Kazuhide
    DIGESTIVE ENDOSCOPY, 2022, 34 (01) : 222 - 227
  • [30] Endoscopic Ultrasound-Guided Gallbladder Drainage Using a Lumen-Apposing Metal Stent for Acute Cholecystitis: A Systematic Review
    Jain, Deepanshu
    Bhandari, Bharat Singh
    Agrawal, Nikhil
    Singhal, Shashideep
    CLINICAL ENDOSCOPY, 2018, 51 (05) : 450 - 462