A Simple Source Model for 6 MV Flattening Filter Free Photon Beams Monte Carlo Dose Calculations

被引:1
作者
Ezzati, Ahad Ollah [1 ]
Studenski, Matthew T. [2 ]
Jamshidi, Negin [1 ]
机构
[1] Univ Tabriz, Dept Phys, Tabriz 5166616471, Iran
[2] Univ Miami, Dept Radiat Oncol, Miami, FL 33331 USA
关键词
source model; FFF photon beams; Monte Carlo; IMRT; MULTIPLE SOURCE MODEL; VIRTUAL SOURCE MODEL; LINEAR-ACCELERATOR; SIMULATION; RADIOTHERAPY; VALIDATION;
D O I
10.1134/S1547477121070037
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
The purpose of this work was to develop a simple source model for Monte Carlo dose calculations of flattening filter free (FFF) 6 MV photon beams. MCNPX2.4 Monte Carlo code was used to simulate 6 MV FFF photon beam from a Varian 2100C/D Clinac. The FFF photon beam features including energy and angular distributions were calculated in a phase space plane located 25.1 cm downstream from the accelerator target. A simple point source model (SM) was developed based on correlated histograms. Differences between measured and calculated profiles were less than 2% of the maximum dose or 2 mm distance to agreement at 100 cm source to surface distance (SSD). Using the obtained SM, percent depth dose and beam profiles were calculated for different field sizes from 3 x 3 to 40 x 40 cm(2). Differences between the SM and Clinac full simulation data were less than 2% or 2 mm distance to agreement at 100 cm SSD. This model is independent of components located above the accelerator movable jaws. Also, it has source biasing capabilities that increase the simulation speed up to 2000 times for certain field sizes. Our simulations showed that the dose rates of the FFF beams are at least two times higher for the same current of incident electrons on the target.
引用
收藏
页码:791 / 798
页数:8
相关论文
共 50 条
[41]   Monte-Carlo simulation of the Siemens Artiste linear accelerator flat 6 MV and flattening filter-free 7 MV beam line [J].
Sadrollahi, Alemeh ;
Nuesken, Frank ;
Licht, Norbert ;
Ruebe, Christian ;
Dzierma, Yvonne .
PLOS ONE, 2019, 14 (01)
[42]   Output factor comparison of Monte Carlo and measurement for Varian TrueBeam 6 MV and 10 MV flattening filter-free stereotactic radiosurgery system [J].
Cheng, Jason Y. ;
Ning, Holly ;
Arora, Barbara C. ;
Ying Zhuge ;
Miller, Robert W. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03) :100-110
[43]   Monte Carlo Simulation of Surface Dose and Dose Rate in 6MV-FFF Beams [J].
Mustapha Assalmi ;
El Yamani Diaf .
Moscow University Physics Bulletin, 2021, 76 :S36-S51
[44]   Impact of Dosimetric Parameters on Interplay Effects in 6 MV Flattening Filter-Free Photon Beams to Treat Lung Cancer [J].
Poolnapol, Vanida ;
Sanghangthum, Taweap ;
Keawsamur, Mintra .
JOURNAL OF MEDICAL PHYSICS, 2022, 47 (01) :20-26
[45]   Beam quality and dose perturbation of 6 MV flattening-filter-free linac [J].
Tsiamas, P. ;
Sajo, E. ;
Cifter, F. ;
Theodorou, K. ;
Kappas, C. ;
Makrigiorgos, M. ;
Marcus, K. ;
Zygmanski, P. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (01) :47-56
[46]   Monte Carlo simulation of 10 MV photon beams and beam profile validations [J].
Tartar, Ahmet .
MEASUREMENT, 2013, 46 (09) :3026-3031
[47]   Depth Dose Enhancement on Flattening-Filter-Free Photon Beam: A Monte Carlo Study in Nanoparticle-Enhanced Radiotherapy [J].
Chow, James C. L. .
APPLIED SCIENCES-BASEL, 2020, 10 (20) :1-10
[48]   Consequences of removing the flattening filter from linear accelerators in generating high dose rate photon beams for clinical applications: A Monte Carlo study verified by measurement [J].
Parsai, E. Ishmael ;
Pearson, David ;
Kvale, Thomas .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 261 (1-2) :755-759
[49]   Effects of 10 MV and Flattening-Filter-Free Beams on Peripheral Dose in a Cohort of Pediatric Patients [J].
Ben Bouchta, Youssef ;
Goddard, Karen ;
Petric, M. Peter ;
Bergman, Alanah M. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (05) :1560-1568
[50]   Commissioning 6 MV photon beams of a stereotactic radiosurgery system for Monte Carlo treatment planning [J].
Deng, J ;
Ma, CM ;
Hai, J ;
Nath, R .
MEDICAL PHYSICS, 2003, 30 (12) :3124-3134