In vivo comparison of tantalum, tungsten, and bismuth enteric contrast agents to complement intravenous iodine for double-contrast dual-energy CT of the bowel

被引:38
|
作者
Rathnayake, Samira [1 ]
Mongan, John [1 ]
Torres, Andrew S. [2 ]
Colborn, Robert [2 ]
Gao, Dong-Wei [1 ]
Yeh, Benjamin M. [1 ]
Fu, Yanjun [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[2] GE Global Res, 1 Res Circle, Niskayuna, NY USA
基金
美国国家卫生研究院;
关键词
dual-energy CT; CT enterography; contrast agent; tungsten; bismuth; tantalum; small bowel; COMPUTED-TOMOGRAPHY; CROHNS-DISEASE; CAPSULE ENDOSCOPY; IMAGING AGENT; MEDIA; METAL; NANOPARTICLES; ENTEROGRAPHY; POWDER;
D O I
10.1002/cmmi.1687
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess the ability of dual-energy CT (DECT) to separate intravenous contrast of bowel wall from intraluminal contrast, we scanned 16 rabbits on a clinical DECT scanner: n = 3 using only iodinated intravenous contrast, and n = 13 double-contrast enhanced scans using iodinated intravenous contrast and experimental enteric non-iodinated contrast agents in the bowel lumen (five bismuth, four tungsten, and four tantalum based). Representative image pairs from conventional CT images and DECT iodine density maps of small bowel (116 pairs from 232 images) were viewed by four abdominal imaging attending radiologists to independently score each comparison pair on a visual analog scale (-100 to +100%) for (1) preference in small bowel wall visualization and (2) preference in completeness of intraluminal enteric contrast subtraction. Median small bowel wall visualization was scored 39 and 42 percentage points (95% CI 30-44% and 36-45%, both p < 0.001) higher for double-contrast DECT than for conventional CT with enteric tungsten and tantalum contrast, respectively. Median small bowel wall visualization for double-contrast DECT was scored 29 and 35 percentage points (95% CI 20-35% and 33-39%, both p < 0.001) higher with enteric tungsten and tantalum, respectively, than with bismuth contrast. Median completeness of intraluminal enteric contrast subtraction in double-contrast DECT iodine density maps was scored 28 and 29 percentage points (95% CI 15-31% and 28-33%, both p < 0.001) higher with enteric tungsten and tantalum, respectively, than with bismuth contrast. Results suggest that in vivo double-contrast DECT with iodinated intravenous and either tantalum-or tungsten-based enteric contrast provides better visualization of small bowel than conventional CT. Copyright (C) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:254 / 261
页数:8
相关论文
共 50 条
  • [31] Task-Based Optimal Dose Partitioning in Dual-Source Dual-Energy CT for Virtual Non-Contrast and Iodine Imaging
    Long, L.
    McCollough, C.
    Yu, L.
    MEDICAL PHYSICS, 2018, 45 (06) : E675 - E675
  • [32] Dual-energy CT of the pancreas: comparison between virtual non-contrast images and true non-contrast images in the detection of pancreatic lesion
    Hongwei Liang
    Silin Du
    Gaowu Yan
    Yang Zhou
    Tianyu Yang
    Zhiwei Zhang
    Chenyi Luo
    Hongfan Liao
    Yongmei Li
    Abdominal Radiology, 2023, 48 : 2596 - 2603
  • [33] Dual-energy CT of the pancreas: comparison between virtual non-contrast images and true non-contrast images in the detection of pancreatic lesion
    Liang, Hongwei
    Du, Silin
    Yan, Gaowu
    Zhou, Yang
    Yang, Tianyu
    Zhang, Zhiwei
    Luo, Chenyi
    Liao, Hongfan
    Li, Yongmei
    ABDOMINAL RADIOLOGY, 2023, 48 (08) : 2596 - 2603
  • [34] Maximizing Iodine Contrast-to-Noise Ratios in Abdominal CT Imaging through Use of Energy Domain Noise Reduction and Virtual Monoenergetic Dual-Energy CT
    Leng, Shuai
    Yu, Lifeng
    Fletcher, Joel G.
    McCollough, Cynthia H.
    RADIOLOGY, 2015, 276 (02) : 562 - 570
  • [35] Optimization of Energy Combination for Gold-Based Contrast Agents Below K-Edges in Dual-Energy Micro-CT
    Yuan, Yuan
    Zhang, Yanbo
    Yu, Hengyong
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2018, 2 (03) : 187 - 193
  • [36] Generation of ventilation/perfusion ratio map in surgical patients by dual-energy CT after xenon inhalation and intravenous contrast media
    Kohei Aoki
    Yotaro Izumi
    Wataru Watanabe
    Yuji Shimizu
    Hisato Osada
    Norinari Honda
    Toshihide Itoh
    Mitsuo Nakayama
    Journal of Cardiothoracic Surgery, 13
  • [37] Assessment of Calcified Carotid Plaque Volume: Comparison of Contrast-Enhanced Dual-Energy CT Angiography and Native Single-Energy CT
    Watanabe, Yoshiyuki
    Nakazawa, Tetsuro
    Higashi, Masahiro
    Itoh, Toshihide
    Naito, Hiroaki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) : W796 - W799
  • [38] Generation of ventilation/perfusion ratio map in surgical patients by dual-energy CT after xenon inhalation and intravenous contrast media
    Aoki, Kohei
    Izumi, Yotaro
    Watanabe, Wataru
    Shimizu, Yuji
    Osada, Hisato
    Honda, Norinari
    Itoh, Toshihide
    Nakayama, Mitsuo
    JOURNAL OF CARDIOTHORACIC SURGERY, 2018, 13
  • [39] Dual-energy Computed Tomography Iodine Map for Breast Cancer: Comparison With Dynamic Contrast-enhanced Magnetic Resonance Imaging
    Goda, Noriko
    Funakoshi, Mahito
    Ono, Chiaki
    Mukaida, Hidenori
    Kaneko, Mayumi
    ANTICANCER RESEARCH, 2023, 43 (09) : 4133 - 4142
  • [40] ON THE POSSIBILITY TO RESOLVE GADOLINIUM- AND CERIUM-BASED CONTRAST AGENTS FROM THEIR CT NUMBERS IN DUAL-ENERGY COMPUTED TOMOGRAPHY
    Malusek, Alexandr
    Henriksson, Lilian
    Eriksson, Peter
    Dahlstrom, Nils
    Tedgren, Asa Carlsson
    Uvdal, Kajsa
    RADIATION PROTECTION DOSIMETRY, 2021, 195 (3-4) : 225 - 231