Modeling and Estimation of Tip Contact Force for Steerable Ablation Catheters

被引:67
|
作者
Khoshnam, Mahta [1 ,2 ]
Skanes, Allan C. [3 ,4 ]
Patel, Rajni V. [1 ,2 ,5 ]
机构
[1] Univ Western Ontario, Dept Elect & Comp Engn, London, ON N6A 5A5, Canada
[2] Canadian Surg Technol & Adv Robot, London, ON N6A 5A5, Canada
[3] Univ Western Ontario, Schulich Sch Med & Dent, London, ON N6A 5A5, Canada
[4] Univ Western Ontario Hosp, London Hlth Sci Ctr, Electrophysiol Lab, London, ON N6A 5A5, Canada
[5] Univ Western Ontario, Dept Surg, London, ON N6A 5A5, Canada
基金
加拿大创新基金会; 加拿大自然科学与工程研究理事会;
关键词
Ablation catheter; contact force; kinematics; modeling;
D O I
10.1109/TBME.2015.2389615
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: The efficacy of catheter-based cardiac ablation procedures can be significantly improved if real-time information is available concerning contact forces between the catheter tip and cardiac tissue. However, the widely used ablation catheters are not equipped for force sensing. This paper proposes a technique for estimating the contact forces without direct force measurements by studying the changes in the shape of the deflectable distal section of a conventional 7-Fr catheter (henceforth called the "deflectable distal shaft," the "deflectable shaft," or the "shaft" of the catheter) in different loading situations. Method: First, the shaft curvature when the tip is moving in free space is studied and based on that, a kinematic model for the deflectable shaft in free space is proposed. In the next step, the shaft shape is analyzed in the case where the tip is in contact with the environment, and it is shown that the curvature of the deflectable shaft provides useful information about the loading status of the catheter and can be used to define an index for determining the range of contact forces exerted by the ablation tip. Results: Experiments with two different steerable ablation catheters show that the defined index can detect the range of applied contact forces correctly in more than 80% of the cases. Based on the proposed technique, a framework for obtaining contact force information by using the shaft curvature at a limited number of points along the deflectable shaft is constructed. Conclusion: The proposed kinematic model and the force estimation technique can be implemented together to describe the catheter's behavior before contact, detect tip/tissue contact, and determine the range of contact forces. Significance: This study proves that the flexibility of the catheter's distal shaft provides a means of estimating the force exerted on tissue by the ablation tip.
引用
收藏
页码:1404 / 1415
页数:12
相关论文
共 50 条
  • [1] Effects of Blood Flow on the Tip Contact Force of Cardiac Ablation Catheters
    Khoshbakht, Reza
    Kheiri, Mojtaba
    Dargahi, Javad
    Hooshiar, Amir
    2022 IEEE INTERNATIONAL SYMPOSIUM ON ROBOTIC AND SENSORS ENVIRONMENTS (ROSE), 2022,
  • [2] Machine-Learning-Based Multi-Modal Force Estimation for Steerable Ablation Catheters
    Arefinia, Elaheh
    Jagadeesan, Jayender
    Patel, Rajni V.
    IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2024, 6 (03): : 1004 - 1016
  • [3] Optical contact force monitoring sensor for cardiac ablation catheters
    Kim, Jang Ah
    Park, Kihong
    Kim, Changmin
    Kulkarni, Atul
    Kim, Taesung
    OPTIK, 2016, 127 (24): : 11823 - 11827
  • [4] Three dimensional force estimation for steerable catheters through bi-point tracking
    Back, Junghwan
    Lindenroth, Lukas
    Rhode, Kawal
    Liu, Hongbin
    SENSORS AND ACTUATORS A-PHYSICAL, 2018, 279 : 404 - 415
  • [5] Validation of the accuracy of contact force measurement by contemporary force-sensing ablation catheters
    Kueffer, Thomas
    Haeberlin, Andreas
    Knecht, Sven
    Baldinger, Samuel H.
    Madaffari, Antonio
    Seiler, Jens
    Muehl, Aline
    Tanner, Hildegard
    Roten, Laurent
    Reichlin, Tobias
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (02) : 292 - 299
  • [6] The impact of steerable sheaths on unblinded contact force during catheter ablation for atrial fibrillation
    Marc W. Deyell
    Glen Wen
    Zachary Laksman
    Matthew T. Bennett
    Santabhanu Chakrabarti
    John A. Yeung-Lai-Wah
    Andrew D. Krahn
    Jason G. Andrade
    Journal of Interventional Cardiac Electrophysiology, 2020, 57 : 417 - 424
  • [7] A Novel Methodology for Comprehensive Modeling of the Kinetic Behavior of Steerable Catheters
    Hu, Xiaohua
    Cao, Lin
    Luo, Yigang
    Chen, Ang
    Zhang, Edwin
    Zhang, W. J.
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2019, 24 (04) : 1785 - 1797
  • [8] The impact of steerable sheaths on unblinded contact force during catheter ablation for atrial fibrillation
    Deyell, Marc W.
    Wen, Glen
    Laksman, Zachary
    Bennett, Matthew T.
    Chakrabarti, Santabhanu
    Yeung-Lai-Wah, John A.
    Krahn, Andrew D.
    Andrade, Jason G.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2020, 57 (03) : 417 - 424
  • [9] Safety and effectiveness of the first contact force ablation catheter with a flexible tip
    Nair, Devi
    Martinek, Martin
    Colley, Judson
    Sundaram, Sri
    Hariharan, Ramesh
    Morales, Gustavo
    Sommer, Philipp
    Healy, Stewart
    Siddiqui, Usman
    Gibson, Douglas
    Chapman, Kristina
    Sarver, Anne
    Lo, Monica
    HEART RHYTHM O2, 2023, 4 (12): : 784 - 793
  • [10] Model-Based Force Estimation of a Steerable Ablation Catheter in the Presence of the Blood Flow
    Tabatabaei, Seyyede Shahrzad
    Kheiri, Mojtaba
    Dargahi, Javad