Image analysis of Doppler Echocardiography for patients with atrial fibrillation

被引:0
作者
Shechner, O [1 ]
Sheinovitz, M [1 ]
Feinberg, M [1 ]
Greenspan, H [1 ]
机构
[1] Tel Aviv Univ, Dept Biomed Engn, IL-69978 Tel Aviv, Israel
来源
2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2 | 2004年
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Image analysis tools are used for the extraction of clinical data from Doppler Echocardiography images. Currently, manual methods are subject to large inter- and intra-observer variability. The proposed automated methodology may provide a more robust method and a powerful tool for noninvasive evaluation of cardiac haemodynamics, especially for patients with Atrial Fibrillation (ATF). ATF patients suffer from a nonhomogenous heart rate, and the shape of the Doppler signal obtained from them differs from beat to beat. This variability requires the averaging of several measures in order to produce acceptable clinical data. The presented methodology works on signals from the Mitral Valve (MV) and the Tricuspid Valve (TV), and detects the envelope of the velocity vs. time function, the Maximal Velocity Envelope (MVE). From the MVE, clinical data is extracted, such as the peak velocity and the area beneath the curve. Parameters taken from several beats in a single image are averaged in order to provide more representative and robust results. Experimental results show a strong correlation between the automatically extracted parameters and parameters acquired manually by an Echo technician.
引用
收藏
页码:488 / 491
页数:4
相关论文
共 7 条
[1]   Estimation of the Doppler ultrasound maximal umbilical waveform envelope: I. Estimation method [J].
Doherty, DA ;
James, IR ;
Newnham, JP .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (10) :1251-1259
[2]  
Gonzales R.C., 1992, DIGITAL IMAGE PROCES
[3]   Beat averaging alternatives for transmitral Doppler flow velocity images [J].
Hall, AF ;
Nudelman, SP ;
Kovacs, SJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (07) :971-979
[4]  
Hart, 2006, PATTERN CLASSIFICATI
[5]   Mechanisms underlying the development of atrial arrhythmias in heart failure [J].
Markides V. ;
Peters N.S. .
Heart Failure Reviews, 2002, 7 (3) :243-253
[6]   COMPARISON OF DIASTOLIC FILLING MODELS AND THEIR FIT TO TRANSMITRAL DOPPLER CONTOURS [J].
NUDELMAN, S ;
MANSON, AL ;
HALL, AF ;
KOVACS, SJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (08) :989-999
[7]   Automated analysis of Doppler ultrasound velocity flow diagrams [J].
Tschirren, J ;
Lauer, RM ;
Sonka, M .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (12) :1422-1425