CT Enterography at 80 kVp With Adaptive Statistical Iterative Reconstruction Versus at 120 kVp With Standard Reconstruction: Image Quality, Diagnostic Adequacy, and Dose Reduction

被引:62
作者
Kaza, Ravi K. [1 ]
Platt, Joel F. [1 ]
Al-Hawary, Mahmoud M. [1 ]
Wasnik, Ashish [1 ]
Liu, Peter S. [1 ]
Pandya, Amit [1 ]
机构
[1] Univ Michigan Hosp, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
adaptive statistical iterative reconstruction; CT enterography; radiation dose; small bowel; LOW-TUBE-VOLTAGE; INITIAL CLINICAL-EXPERIENCE; ABDOMINAL CT; CROHNS-DISEASE; DUAL-ENERGY; CONTRAST ENHANCEMENT; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; OPTIMIZATION; FEASIBILITY;
D O I
10.2214/AJR.11.6597
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to evaluate the image quality and diagnostic adequacy of the following two CT enterography protocols in patients weighing less than 160 lb (72 kg): 80-kVp imaging with the adaptive statistical iterative reconstruction (ASIR) in comparison with 120-kVp imaging with the filtered back projection reconstruction. MATERIALS AND METHODS. We retrospectively reviewed 133 CT enterography examinations of 127 patients weighing less than 160 lb, 64 80-kVp examinations, and 69 120-kVp examinations. Image quality for evaluation of the bowel wall, mesenteric vessels, and hepatic parenchyma and the overall image quality were graded on a scale of 1-5 (1 = poor, 2 = acceptable, 3 = good, 4 = very good, 5 = excellent). Diagnostic accuracy for the detection of inflammatory bowel disease was evaluated. The volume CT dose index (CTDIvol) was recorded and effective dose was calculated from scanner-generated dose-length product. RESULTS. There was a statistically significant decrease in the mean image quality scores for 80-kVp examinations compared with 120-kVp examinations for evaluation of the bowel wall (3.19 vs 3.70, respectively) and liver (3.12 vs 3.81) and for overall image quality (3.23 vs 3.68), but there was no significant decrease in score for evaluation of the mesenteric vessels (3.63 vs 3.67). None of the 80-kVp examinations was graded as poor, and all were considered to be of acceptable quality. Both techniques had comparable diagnostic accuracy for the detection of inflammatory bowel disease. Interobserver agreement was fair to moderate for qualitative image grading and was substantial for the detection of features of inflammatory bowel disease. The mean CTDIvol and effective dose for the 80-kVp examinations were 6.15 mGy and 4.60 mSv, respectively, and for the 120-kVp examinations, 20.79 mGy and 15.81 mSv. CONCLUSION. In patients weighing less than 160 lb, CT enterography examinations at 80 kVp with 30% ASIR produce diagnostically acceptable image quality with an average CTDIvol of 6.15 mGy and an average effective dose of 4.60 mSv.
引用
收藏
页码:1084 / 1092
页数:9
相关论文
共 39 条
[1]   Effect of Altering Automatic Exposure Control Settings and Quality Reference mAs on Radiation Dose, Image Quality, and Diagnostic Efficacy in MDCT Enterography of Active Inflammatory Crohn's Disease [J].
Allen, Brian C. ;
Baker, Mark E. ;
Einstein, David M. ;
Remer, Erick M. ;
Herts, Brian R. ;
Achkar, Jean-Paul ;
Davros, William J. ;
Novak, Eric ;
Obuchowski, Nancy A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (01) :89-100
[2]  
*AM COLL RAD, 2008, ACR PRACT GUID DIAGN
[3]   Should computed tomography be the modality of choice for imaging Crohn's disease in children? The radiation risk perspective [J].
Brenner, David J. .
GUT, 2008, 57 (11) :1489-1490
[4]   CT enterography technique: theme and variations [J].
Fletcher, J. G. .
ABDOMINAL IMAGING, 2009, 34 (03) :283-288
[5]   Dual-Energy and Dual-Source CT: Is There a Role in the Abdomen and Pelvis? [J].
Fletcher, Joel G. ;
Takahashi, Naoki ;
Hartman, Robert ;
Guimaraes, Luis ;
Huprich, James E. ;
Hough, David M. ;
Yu, Lifeng ;
McCollough, Cynthia H. .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2009, 47 (01) :41-+
[6]   Appropriate Patient Selection at Abdominal Dual-Energy CT Using 80 kV: Relationship between Patient Size, Image Noise, and Image Quality [J].
Guimaraes, Luis S. ;
Fletcher, Joel G. ;
Harmsen, William S. ;
Yu, Lifeng ;
Siddiki, Hassan ;
Melton, Zachary ;
Huprich, James E. ;
Hough, David ;
Hartman, Robert ;
McCollough, Cynthia H. .
RADIOLOGY, 2010, 257 (03) :732-742
[7]   Feasibility of Dose Reduction Using Novel Denoising Techniques for Low kV (80 kV) CT Enterography: Optimization and Validation [J].
Guimaraes, Luis S. ;
Fletcher, Joel G. ;
Yu, Lifeng ;
Huprich, James E. ;
Fidler, Jeff L. ;
Manduca, Armando ;
Ramirez-Giraldo, Juan Carlos ;
Holmes, David R., Jr. ;
McCollough, Cynthia H. .
ACADEMIC RADIOLOGY, 2010, 17 (10) :1203-1210
[8]   Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility Study [J].
Hara, Amy K. ;
Paden, Robert G. ;
Silva, Alvin C. ;
Kujak, Jennifer L. ;
Lawder, Holly J. ;
Pavlicek, William .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (03) :764-771
[9]   CT enterography of Crohn's disease [J].
Hara, Amy K. ;
Swartz, Paul G. .
ABDOMINAL IMAGING, 2009, 34 (03) :289-295
[10]  
International Commission on Radiological Protection, 1990, ICRP PUBL, V60