A microstrip germanium detector for position-sensitive X-ray spectroscopy

被引:17
作者
Protic, D [1 ]
Stöhlker, T
Beyer, HF
Bojowald, J
Borchert, G
Gumberidze, A
Hamacher, A
Kozhuharov, C
Ma, X
Mohos, I
机构
[1] Forschungszentrum Julich GmbH, Inst Kernphys, D-52425 Julich, Germany
[2] GSI Darmstadt, D-64291 Darmstadt, Germany
关键词
crystal spectrometer; germanium radiation detectors; heavy ions; Lamb-shift; microstrip; position-sensitive detectors; X-ray spectroscopy detectors;
D O I
10.1109/23.958721
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For the current X-ray spectroscopy program at the ESR storage ring (GSI-Darmstadt), a position-sensitive germanium detector system was completed. The position-sensitive structure of the detector was realized on an area of 47 x 23.4 mm by an array of 200 strips (200 mum wide and 23.4 mm long) separated by 35-mum-wide grooves etched through boron implanted contact. The thickness of the detector, including a 0.6-mm-thick Li-diffused rear contact, amounts to 4.1 mm. Each strip has been joined to a preamplifier placed outside the cryostat with printed leads inside the flexible Kapton-foil. The energy resolution of the strips was about 1.8 keV [FWHM] for 60-keV photons. Coincidences between neighboring strips were measured showing that a time resolution of 70 ns [FWHM] was obtained. First preliminary results obtained with the detector mounted at the transmission X-ray spectrometer FOCAL demonstrated that an energy resolution better than 100 eV is achievable together with a high detection efficiency. Along with a new kind of X-ray spectrometer, this detector may play a key role for the next step of high-precision X-ray experiments: aiming for a precise test of quantum electrodynamics in the heaviest one-electron systems, such as hydrogen-like uranium.
引用
收藏
页码:1048 / 1052
页数:5
相关论文
共 9 条
[1]   A small size zero-degree spectrometer with germanium detectors [J].
Bargholtz, C ;
Lindh, K ;
Protic, D ;
Ruus, N ;
Tegner, PE ;
Engblom, PT ;
Rolander, KW .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 390 (1-2) :160-166
[2]   PERFORMANCE OF A GE 200-STRIP DETECTOR FOR INELASTIC X-RAY-SCATTERING STUDIES [J].
BERTHOLD, A ;
DEGENHARDT, J ;
MOURIKIS, S ;
SCHMITZ, JR ;
SCHULKE, W ;
SCHULTESCHREPPING, H ;
WOHLERT, F ;
HAMACHER, A ;
PROTIC, D ;
RIEPE, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 320 (1-2) :375-380
[3]   The germanium wall of the GEM detector system [J].
Betigeri, M ;
Bialkowski, E ;
Bojowald, H ;
Budzanowski, A ;
Chatterjee, A ;
Drochner, M ;
Ernste, J ;
Förtsch, S ;
Freindl, L ;
Frekers, D ;
Garske, W ;
Grewer, K ;
Hamacher, A ;
Igel, S ;
Ilieva, J ;
Jarczyk, L ;
Jochmann, M ;
Kemmerling, G ;
Kilian, K ;
Kliczewski, S ;
Klimala, W ;
Kolev, D ;
Kutsarova, T ;
Lieb, J ;
Lippert, G ;
Machner, H ;
Magiera, A ;
Nann, H ;
Pentchev, L ;
Plendl, HS ;
Protic, D ;
Razen, B ;
von Rossen, P ;
Roy, BJ ;
Siudak, R ;
Smyrski, J ;
Srikantiah, RV ;
Strzalkowski, A ;
Tsenov, R ;
Zolnierczuk, PA ;
Zwoll, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 421 (03) :447-457
[5]  
BEYER HF, 2000, FOCUSING COMPENSATED
[6]   PERFORMANCE OF POSITION-SENSITIVE GERMANIUM DETECTORS IN NUCLEAR-REACTION EXPERIMENTS [J].
HAMACHER, A ;
MACHNER, H ;
NOLTE, M ;
PALARCZYK, M ;
PROTIC, D ;
RIEPE, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 295 (1-2) :128-132
[7]  
RIEPE G, 1979, POSITRON ANNIHILATIO, P371
[8]   Energy and position resolution of germanium microstrip detectors at X-ray energies from 15 to 100 keV [J].
Rossi, G ;
Morse, J ;
Protic, D .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :765-773
[9]  
STROHLKER T, 1997, PHYS SCRIPTA, V73, P29