Fatigue strength of hot-dip galvanized S960 cut edges and longitudinal welds

被引:8
作者
Lipiainen, Kalle [1 ]
Ahola, Antti [1 ]
Virolainen, Esa [2 ]
Hirvi, Ari [3 ]
Bjork, Timo [1 ]
机构
[1] Lappeenranta Lahti Univ Technol LUT, Lab Steel Struct, POB 20, FI-53851 Lappeenranta, Finland
[2] SSAB Europe, POB 93, FI-92101 Raahe, Finland
[3] SSAB Special Steels, POB 93, FI-92101 Raahe, Finland
关键词
Fatigue strength; Hot-dip galvanizing; Ultra-high-strength steel; Cut edge; Welded joint;
D O I
10.1016/j.jcsr.2021.107083
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Experimental fatigue test series were conducted for component sized hot-dip galvanized (HDG) S960 cut edges and longitudinal welds. Scanning electron microscopy (SEM) was used to identify and characterize the crack initiation location and the effects of local chemical composition. Micro-scale liquid metal embrittlement in the vicinity of the cut surface was found to slightly reduce fatigue performance of tested laser cut, machined and welded specimens. The use of ultra-high-strength steels in the HDG condition is discussed and fatigue strength guidelines are proposed for the tested details.
引用
收藏
页数:11
相关论文
共 20 条
[1]   Fatigue strength assessment of ultra-high-strength steel fillet weld joints using 4R method [J].
Ahola, A. ;
Skriko, T. ;
Bjork, T. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 167
[2]  
[Anonymous], 2020, 147132 EN ISO
[3]  
[Anonymous], 2021, EUROCODE 3
[4]  
[Anonymous], 2009, 1461 EN ISO, P1
[5]  
[Anonymous], 2019, 13001312018 EN
[6]  
[Anonymous], 2014, 58172014 SS EN ISO, P1
[7]   Revision of fatigue detail categories of plain members and mechanically fastened joints according to EC3-1-9 [J].
Bartsch, Helen ;
Feldmann, Markus .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 179
[8]  
European General Galvanizers Association, 2014, CONTR LIQ MET ASS CR
[9]  
Feldmann M., 2010, FOSTA BERICHTE
[10]   On the fatigue behaviour of hot dip galvanized structural steel details [J].
Ferraz, Goncalo ;
Rossi, Barbara .