Modeling of the chromatographic solvent gradient reversed phase purification of a multicomponent polypeptide mixture

被引:8
作者
Aumann, Lars [1 ]
Butte, Alessandro [1 ]
Morbidelli, Massimo [1 ]
Buescher, Klaus [2 ]
Schenkel, Berthold [2 ]
机构
[1] Swiss Fed Inst Technol, Inst Chem Bioengn, Dept Chem & Appl Biosci, CH-8093 Zurich, Switzerland
[2] NOVARTIS Pharma AG, Basel, Switzerland
关键词
reversed-phase chromatography; chromatographic modeling; peptide purification; multicomponent competitive adsorption isotherm; bi-Langmuir isotherm; solvent gradient chromatography;
D O I
10.1080/01496390801941026
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A model for Calcitonin purification from an industrial peptide mixture using polymer-based reversed phase columns was developed. Regressed competitive bi-Langmuir isotherm parameters for pure calcitonin are strong functions of the eluent composition and were correlated to the overall Henry coefficient only. It is shown that, by keeping constant these correlations, the adsorption behavior of impurities can be predicted simply by estimating their Henry coefficient from the raw mixture. The same can be repeated with very good results when changing the stationary phase or the organic solvent in the eluent. In both cases, only the Henry coefficient must be re-estimated from pulse injections.
引用
收藏
页码:1310 / 1337
页数:28