Nonlinear decrease of background fluorescence in polymer thin-films -: a survey of materials and how they can complicate fluorescence detection in μTAS

被引:66
作者
Hawkins, KR [1 ]
Yager, P [1 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
来源
LAB ON A CHIP | 2003年 / 3卷 / 04期
关键词
D O I
10.1039/b307772c
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Polymers and plastics are receiving increased attention as materials for microfluidics and muTAS applications. Given the ubiquity of fluorescence detection techniques in micro-analytical systems, the fluorescence properties of polymers and plastics should not be overlooked. We survey some commonly available polymer thin-films for their fluorescence behaviour under standardized conditions to determine which materials are most suitable for high-sensitivity fluorescence detection lab chips. The initial fluorescence intensities of some of the materials surveyed were significantly higher than glass and fused silica controls, and decreased over the three hour period with complex kinetics. We then discuss how this has confounded fluorescence detection in our analytical context, and possible mechanisms for the decrease.
引用
收藏
页码:248 / 252
页数:5
相关论文
共 21 条
  • [1] Assessment of one- and two-photon excited luminescence for directly measuring O2, pH, Na+, Mg2+, or Ca2+ in optically dense and biologically relevant samples
    Baker, GA
    Munson, CA
    Bukowski, EJ
    Baker, SN
    Bright, FV
    [J]. APPLIED SPECTROSCOPY, 2002, 56 (04) : 455 - 463
  • [2] Polymer microfluidic devices
    Becker, H
    Locascio, LE
    [J]. TALANTA, 2002, 56 (02) : 267 - 287
  • [3] Plastic advances microfluidic devices.
    Boone, T
    Fan, ZH
    Hooper, H
    Ricco, A
    Tan, HD
    Williams, S
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (03) : 78A - 86A
  • [4] Plastic fantastic?
    de Mello, A
    [J]. LAB ON A CHIP, 2002, 2 (02) : 31N - 36N
  • [5] ELLISON EH, 1995, ACS S SER, V598
  • [6] Gaigalas AK, 2002, PHOTOCHEM PHOTOBIOL, V76, P22, DOI 10.1562/0031-8655(2002)076<0022:FDMOTP>2.0.CO
  • [7] 2
  • [8] Multi-level optical data storage in a photobleaching polymer using two-photon excitation under continuous wave illumination
    Ganic, D
    Day, D
    Gu, M
    [J]. OPTICS AND LASERS IN ENGINEERING, 2002, 38 (06) : 433 - 437
  • [9] A rapid diffusion immunoassay in a T-sensor
    Hatch, A
    Kamholz, AE
    Hawkins, KR
    Munson, MS
    Schilling, EA
    Weigl, BH
    Yager, P
    [J]. NATURE BIOTECHNOLOGY, 2001, 19 (05) : 461 - 465
  • [10] CO2-laser micromachining and back-end processing for rapid production of PMMA-based microfluidic systems
    Klank, H
    Kutter, JP
    Geschke, O