Enhancing sensitivity of liquid chromatographic/ion-trap tandem mass spectrometric determination of estrogens by on-line pre-column derivatization

被引:32
作者
Matejicek, David [1 ]
Kuban, Vlastimil [1 ]
机构
[1] Mendel Univ Brno, Dept Chem & Biochem, CZ-61300 Brno, Czech Republic
关键词
estrogens; derivatization; liquid chromatography; ion-trap MS/MS; water;
D O I
10.1016/j.chroma.2008.03.061
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid and sensitive liquid chromatographic/ion-trap mass spectrometric method has been developed for the simultaneous determination of estriol, alpha-, beta-estradiol, 17 alpha-ethynylestradiol and estrone The sub. stances were extracted from river water samples (typically 250 ml) and cleaned-up using two-stage solid-phase extraction (SPE). 12-(Difluoro-1,3,5-triazinyl)-benz[f]isoindolo-[1,2b][1,3]benzothiazolidine was applied as a derivatizing agent. The recovery for each compounds ranged from 75 to 88% and the repeatability represented as RSDs ranged from 5.6 to 8.4%. Limits of detection (LOD, 3 x S/N) were 67-285 pg/l. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:248 / 253
页数:6
相关论文
共 20 条
[1]   Monitoring natural and synthetic estrogens at activated sludge sewage treatment plants and in a receiving river water [J].
Baronti, C ;
Curini, R ;
D'Ascenzo, G ;
Di Corcia, A ;
Gentili, A ;
Samperi, R .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (24) :5059-5066
[2]   Analysis of multiple endocrine disruptors in environmental waters via wide-spectrum solid-phase extraction and dual-polarity ionization LC-ion trap-MS/MS [J].
Benijts, T ;
Lambert, W ;
De Leenheer, A .
ANALYTICAL CHEMISTRY, 2004, 76 (03) :704-711
[3]   Review of analytical methods for the determination of estrogens and progestogens in waste waters [J].
De López Aida M.J. ;
Barceló D. .
Fresenius' Journal of Analytical Chemistry, 2001, 371 (4) :437-447
[4]   Determination of estrogens and progestogens by mass spectrometric techniques (GC/MS, LC/MS and LC/MS/MS) [J].
Díaz-Cruz, MS ;
de Alda, MJL ;
López, R ;
Barceló, D .
JOURNAL OF MASS SPECTROMETRY, 2003, 38 (09) :917-923
[5]   Evaluation of commercial immunoassays for the detection of estrogens in water by comparison with high-performance liquid chromatography tandem mass spectrometry HPLC-MS/MS (QqQ) [J].
Farre, Marinella ;
Brix, Rikke ;
Kuster, Marina ;
Rubio, Fernando ;
Goda, Yasuhiro ;
de Alda, Mara J. Lopez ;
Barcelo, Damia .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (06) :1001-1011
[6]   Determination of steroid estrogens in wastewater by immunoaffinity extraction coupled with HPLC-Electrospray-MS [J].
Ferguson, PL ;
Iden, CR ;
McElroy, AE ;
Brownawell, BJ .
ANALYTICAL CHEMISTRY, 2001, 73 (16) :3890-3895
[7]   12-(DIFLUORO-1,3,5-TRIAZINYL)-BENZ[F]ISOINDOLO[1,2-B][1,3]BENZOTHIAZOLIDINE AS A FLUORESCENT LABELING REAGENT FOR ESTROGENS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
FUJINO, H ;
GOYA, S .
ANALYTICAL SCIENCES, 1992, 8 (05) :715-717
[8]   Procedure for increasing the detection responses of estrogens in LC-MS based on introduction of a nitrobenzene moiety followed by electron capture atmospheric pressure chemical ionization [J].
Higashi, Tatsuya ;
Takayama, Naoki ;
Nishio, Tadashi ;
Taniguchi, Emi ;
Shimada, Kazutake .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (03) :658-665
[9]  
Ingerslev F, 2003, 44 DAN ENV PROT AG
[10]   Analysis of steroid hormones in effluents of wastewater treatment plants by liquid chromatography-tandem mass spectrometry [J].
Ingrand, V ;
Herry, G ;
Beausse, J ;
de Roubin, MR .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1020 (01) :99-104