Enhancing sensitivity of liquid chromatographic/ion-trap tandem mass spectrometric determination of estrogens by on-line pre-column derivatization

被引:30
作者
Matejicek, David [1 ]
Kuban, Vlastimil [1 ]
机构
[1] Mendel Univ Brno, Dept Chem & Biochem, CZ-61300 Brno, Czech Republic
关键词
estrogens; derivatization; liquid chromatography; ion-trap MS/MS; water;
D O I
10.1016/j.chroma.2008.03.061
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid and sensitive liquid chromatographic/ion-trap mass spectrometric method has been developed for the simultaneous determination of estriol, alpha-, beta-estradiol, 17 alpha-ethynylestradiol and estrone The sub. stances were extracted from river water samples (typically 250 ml) and cleaned-up using two-stage solid-phase extraction (SPE). 12-(Difluoro-1,3,5-triazinyl)-benz[f]isoindolo-[1,2b][1,3]benzothiazolidine was applied as a derivatizing agent. The recovery for each compounds ranged from 75 to 88% and the repeatability represented as RSDs ranged from 5.6 to 8.4%. Limits of detection (LOD, 3 x S/N) were 67-285 pg/l. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:248 / 253
页数:6
相关论文
共 20 条
  • [1] Monitoring natural and synthetic estrogens at activated sludge sewage treatment plants and in a receiving river water
    Baronti, C
    Curini, R
    D'Ascenzo, G
    Di Corcia, A
    Gentili, A
    Samperi, R
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (24) : 5059 - 5066
  • [2] Analysis of multiple endocrine disruptors in environmental waters via wide-spectrum solid-phase extraction and dual-polarity ionization LC-ion trap-MS/MS
    Benijts, T
    Lambert, W
    De Leenheer, A
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (03) : 704 - 711
  • [3] Review of analytical methods for the determination of estrogens and progestogens in waste waters
    De López Aida M.J.
    Barceló D.
    [J]. Fresenius' Journal of Analytical Chemistry, 2001, 371 (4): : 437 - 447
  • [4] Determination of estrogens and progestogens by mass spectrometric techniques (GC/MS, LC/MS and LC/MS/MS)
    Díaz-Cruz, MS
    de Alda, MJL
    López, R
    Barceló, D
    [J]. JOURNAL OF MASS SPECTROMETRY, 2003, 38 (09): : 917 - 923
  • [5] Evaluation of commercial immunoassays for the detection of estrogens in water by comparison with high-performance liquid chromatography tandem mass spectrometry HPLC-MS/MS (QqQ)
    Farre, Marinella
    Brix, Rikke
    Kuster, Marina
    Rubio, Fernando
    Goda, Yasuhiro
    de Alda, Mara J. Lopez
    Barcelo, Damia
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (06) : 1001 - 1011
  • [6] Determination of steroid estrogens in wastewater by immunoaffinity extraction coupled with HPLC-Electrospray-MS
    Ferguson, PL
    Iden, CR
    McElroy, AE
    Brownawell, BJ
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (16) : 3890 - 3895
  • [7] 12-(DIFLUORO-1,3,5-TRIAZINYL)-BENZ[F]ISOINDOLO[1,2-B][1,3]BENZOTHIAZOLIDINE AS A FLUORESCENT LABELING REAGENT FOR ESTROGENS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    FUJINO, H
    GOYA, S
    [J]. ANALYTICAL SCIENCES, 1992, 8 (05) : 715 - 717
  • [8] Procedure for increasing the detection responses of estrogens in LC-MS based on introduction of a nitrobenzene moiety followed by electron capture atmospheric pressure chemical ionization
    Higashi, Tatsuya
    Takayama, Naoki
    Nishio, Tadashi
    Taniguchi, Emi
    Shimada, Kazutake
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (03) : 658 - 665
  • [9] Ingerslev F, 2003, 44 DAN ENV PROT AG
  • [10] Analysis of steroid hormones in effluents of wastewater treatment plants by liquid chromatography-tandem mass spectrometry
    Ingrand, V
    Herry, G
    Beausse, J
    de Roubin, MR
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 1020 (01) : 99 - 104