Test-retest reliability and repeatability of renal diffusion tensor MRI in healthy subjects

被引:33
|
作者
Cutajar, Marica [1 ]
Clayden, Jonathan D. [1 ]
Clark, Christopher A. [1 ]
Gordon, Isky [1 ]
机构
[1] UCL, Imaging & Biophys Unit, Inst Child Hlth, London WC1N 1EH, England
关键词
Renal MRI; Diffusion tensor imaging; Repeatability study; KIDNEY; COEFFICIENT; FEASIBILITY; SEQUENCES; DISEASE;
D O I
10.1016/j.ejrad.2010.12.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study assessed test-retest reliability and repeatability of diffusion tensor imaging (DTI) in the kidneys. Materials and methods: Seven healthy volunteers (age range, 19-31 years), were imaged three consecutive times on the same day (short-term reliability) and the same imaging protocol was repeated after a month (long-term reliability). Diffusion-weighted magnetic resonance imaging scans in the coronal-oblique projection of the kidney were acquired on a 1.5 T scanner using a multi-section echo-planar sequence; six contiguous slices each 5 mm thick, diffusion sensitisation along 20 non-collinear directions, TR = 730 ms, TE = 73 ms and 2 b-values (0 and 400 s mm(-2)). Volunteers were asked to hold their breath throughout each data acquisition (approx. 20 s). The apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values were obtained from maps generated using dedicated software MIStar (Apollo Medical Imaging, Melbourne, Australia). Results: Statistical analyses of both short-and long-term repeats were carried out from which the within-subject coefficient of variation (wsCV) was calculated. The wsCV obtained for both the ADC and FA values were less than 10% in all the analyses carried out. In addition, paired (repeated measures) t-test was used to measure the variation between the diffusion parameters collected from the two scanning sessions a month apart. It showed no significant difference and the wsCV obtained after comparing the first and second scans were found to be smaller than 15% for both ADC and FA. Conclusion: Renal DTI produces reliable and repeatable results which make longitudinal investigation of patients viable. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E263 / E268
页数:6
相关论文
共 50 条
  • [1] Multiparametric Renal MRI: An Intrasubject Test-Retest Repeatability Study
    de Boer, Anneloes
    Harteveld, Anita A.
    Stemkens, Bjorn
    Blankestijn, Peter J.
    Bos, Clemens
    Franklin, Suzanne L.
    Froeling, Martijn
    Joles, Jaap A.
    Verhaar, Marianne C.
    van den Berg, Nico
    Hoogduin, Hans
    Leiner, Tim
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (03) : 859 - 873
  • [2] Test-retest Repeatability of a Novel Color Perimeter in a Cohort of Healthy Subjects
    Owusu-Afriyie, Bismark
    Wu, Christopher
    Burhans, Liam
    Coates, Daniel R.
    Harrison, Wendy Watkins
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [3] Test-retest reliability of Diffusion Tensor Imaging metrics in neonates
    Merisaari, Harri
    Tuulari, Jetro J.
    Karlsson, Linnea
    Scheinin, Noora M.
    Parkkola, Riitta
    Saunavaara, Jani
    Lahdesmaki, Tuire
    Lehtola, Satu J.
    Keskinen, Maria
    Lewis, John D.
    Evans, Alan C.
    Karlsson, Hasse
    NEUROIMAGE, 2019, 197 : 598 - 607
  • [4] Test-retest reliability of vestibular autorotation testing in healthy subjects
    Guyot, JP
    Psillas, G
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1997, 117 (06) : 704 - 707
  • [5] Test-retest reliability of diffusion tensor imaging of the liver at 3.0 T
    Girometti, Rossano
    Maieron, Marta
    Lissandrello, Giovanni
    Bazzocchi, Massimo
    Zuiani, Chiara
    RADIOLOGIA MEDICA, 2015, 120 (06): : 489 - 497
  • [6] Test-retest reliability of functional MRI
    Tallent, KA
    Ramsey, NF
    Frank, JA
    Moonen, CT
    Weinberger, DR
    INTERNATIONAL JOURNAL OF PSYCHOLOGY, 1996, 31 (3-4) : 12451 - 12451
  • [7] Test-retest repeatability of the apparent diffusion coefficient in sacroiliac joint MRI in patients with axial spondyloarthritis and healthy individuals
    Moller, Jakob M.
    Ostergaard, Mikkel
    Thomsen, Henrik S.
    Sorensen, Inge J.
    Madsen, Ole R.
    Pedersen, Susanne J.
    ACTA RADIOLOGICA OPEN, 2020, 9 (03)
  • [8] Test-retest reliability of high spatial resolution diffusion tensor and diffusion kurtosis imaging
    Shahim, Pashtun
    Holleran, Laurena
    Kim, Joong H.
    Brody, David L.
    SCIENTIFIC REPORTS, 2017, 7
  • [9] Test-retest reliability of DSC MRI CBV mapping in healthy volunteers
    Henry, ME
    Kaufman, MJ
    Lange, N
    Schmidt, ME
    Purcell, S
    Cote, J
    Perron-Henry, DM
    Stoddard, E
    Cohen, BM
    Renshaw, PF
    NEUROREPORT, 2001, 12 (08) : 1567 - 1569
  • [10] Test-retest reliability of high spatial resolution diffusion tensor and diffusion kurtosis imaging
    Pashtun Shahim
    Laurena Holleran
    Joong H. Kim
    David L. Brody
    Scientific Reports, 7