Effect of Light Curing Distance on Microhardness Profiles of Bulk-Fill Resin Composites

被引:14
作者
Hasanain, Fatin A. [1 ]
Nassar, Hani M. [1 ]
Ajaj, Reem A. [1 ]
机构
[1] King Abdulaziz Univ, Fac Dent, Dept Restorat Dent, Jeddah 21589, Saudi Arabia
关键词
microhardness; bulk-fill composites; microhardness ratio; POLYMERIZATION SHRINKAGE; CURE; DEPTH; EFFICIENCY; CONVERSION; HARDNESS;
D O I
10.3390/polym14030528
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Bulk-fill (BF) dental resin composites are made to be polymerized in increments of up to 5 mm rather than the 2 mm increment recommended for conventional composites. This project aimed to determine microhardness (MH) profiles of BF resin composites at different depths and varying light cure (LC) distances from the light source in an attempt to mimic varying clinical situations. Forty-eight cylindrical specimens (4 mm diameter and 6 mm height) were prepared from 3 BF composites: Tetric N-Ceram Bulk-Fill (TBF), Filtek One Bulk-Fill (FBF), and Sonic-Fill 2 (SF2). Four different distances (0, 2, 4, and 6 mm) from the LC unit were investigated. Vickers MH was measured at the top and bottom of the samples and at every 1 mm, by creating 3 indentations at each depth. The bottom-top microhardness ratio (MHR) and percentage reduction in MHR were also measured. Data was analyzed using mixed-model repeated-measure ANOVA at 0.05 significance level. The main variables effects "material, LC distance, and depth" were significant (p < 0.001). Increasing LC distance and the depth of the tested BF significantly affected Vickers MH and MHR. None of the tested BF materials had sufficient MHR at the depths of 4-6 mm. SF2 showed the least MHR reduction.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Relationship between battery level and irradiance of light-curing units and their effects on the hardness of a bulk-fill composite resin
    Oku Prochnow, Fernanda Harumi
    Manozzo Kunz, Patricia Valeria
    Correr, Gisele Maria
    Kaizer, Marina da Rosa
    Gonzaga, Carla Castiglia
    RESTORATIVE DENTISTRY AND ENDODONTICS, 2022, 47 (04)
  • [22] The Effect of Two Different Light-Curing Units and Curing Times on Bulk-Fill Restorative Materials
    Bayrak, Gokcen Deniz
    Yaman-Dosdogru, Elif
    Selvi-Kuvvetli, Senem
    POLYMERS, 2022, 14 (09)
  • [23] The influence of two different curing regimens on light energy transmission through bulk-fill resin composites and Vickers hardness
    Aldossary, Mohammed Saeed
    Santini, Arno
    AMERICAN JOURNAL OF DENTISTRY, 2016, 29 (05) : 282 - 288
  • [24] The effects of extended curing time and radiant energy on microhardness and temperature rise of conventional and bulk-fill resin composites
    Par, Matej
    Repusic, Igor
    Skenderovic, Hrvoje
    Milat, Ognjen
    Spajic, Jelena
    Tarle, Zrinka
    CLINICAL ORAL INVESTIGATIONS, 2019, 23 (10) : 3777 - 3788
  • [25] Effect of Hydrothermal Factors on the Microhardness of Bulk-Fill and Nanohybrid Composites
    Pieniak, Daniel
    Niewczas, Agata M. M.
    Pikula, Konrad
    Gil, Leszek
    Krzyzak, Aneta
    Przystupa, Krzysztof
    Kordos, Pawel
    Kochan, Orest
    MATERIALS, 2023, 16 (05)
  • [26] How light attenuation and filler content affect the microhardness and polymerization shrinkage and translucency of bulk-fill composites?
    Son, Sung-Ae
    Park, Jeong-Kil
    Seo, Deog-Gyu
    Ko, Ching-Chang
    Kwon, Yong Hoon
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (02) : 559 - 565
  • [27] Influence of irradiation time on subsurface degree of conversion and microhardness of high-viscosity bulk-fill resin composites
    Tarle, Z.
    Attin, T.
    Marovic, D.
    Andermatt, L.
    Ristic, M.
    Tauboeck, T. T.
    CLINICAL ORAL INVESTIGATIONS, 2015, 19 (04) : 831 - 840
  • [28] The effect of rapid high-intensity light-curing on micromechanical properties of bulk-fill and conventional resin composites
    Par, Matej
    Marovic, Danijela
    Attin, Thomas
    Tarle, Zrinka
    Tauboeck, Tobias T.
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [29] Genotoxic potential of dental bulk-fill resin composites
    Tauboeck, Tobias T.
    Marovic, Danijela
    Zeljezic, Davor
    Steingruber, Andrea D.
    Attin, Thomas
    Tarle, Zrinka
    DENTAL MATERIALS, 2017, 33 (07) : 788 - 795
  • [30] The Effect of Different Light-curing Units and Tip Distances on the Polymerization Efficiency of Bulk-fill Materials
    Al Nahedh, H. N. A.
    Al-Senan, D. F.
    Alayad, A. S.
    OPERATIVE DENTISTRY, 2022, 47 (04) : E197 - E210