A novel rectal applicator for contact radiotherapy with HDR 192Ir sources

被引:6
作者
Bellezzo, Murillo [1 ,2 ]
Fonseca, Gabriel P. [1 ]
Verrijssen, An-Sofie [1 ]
Voncken, Robert [1 ]
Van den Bosch, Michiel R. [1 ]
Yoriyaz, Helio [2 ]
Reniers, Brigitte [3 ]
Berbee, Maaike [1 ]
Van Limbergen, Evert J. [1 ]
Verhaegen, Frank [1 ]
机构
[1] Maastricht Univ, Dept Radiat Oncol MAASTRO, GROW Sch Oncol & Dev Biol, Med Ctr, NL-6201 BN Maastricht, Netherlands
[2] Inst Pesquisas Energet & Nucl IPEN CNEN SP, Ctr Engn Nucl, Sao Paulo, Brazil
[3] Hasselt Univ, Res Grp NuTeC, Ctr Environm Sci, Diepenbeek, Belgium
关键词
Brachytherapy; Monte Carlo; Contact radiotherapy; Rectal applicator; QUALITY-OF-LIFE; X-RAY THERAPY; RADIATION-THERAPY; MONTE-CARLO; ORGAN PRESERVATION; TECHNICAL NOTE; BRACHYTHERAPY; CANCER; DOSIMETRY; ADENOCARCINOMA;
D O I
10.1016/j.brachy.2018.07.012
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: Dose escalation to rectal tumors leads to higher complete response rates and may thereby enable omission of surgery. Important advantages of endoluminal boosting techniques include the possibility to apply a more selective/localized boost than using external beam radiotherapy. A novel brachytherapy (BT) rectal applicator with lateral shielding was designed to be used with a rectoscope for eye-guided positioning to deliver a dose distribution similar to the one of contact x-ray radiotherapy devices, using commonly available high-dose-rate Ir-192 BT sources. METHODS AND MATERIALS: A cylindrical multichannel BT applicator with lateral shielding was designed by Monte Carlo modeling, validated experimentally with film dosimetry and compared with results found in the literature for the Papillon 50 (P50) contact x-ray radiotherapy device regarding rectoscope dimensions, radiation beam shape, dose fall-off, and treatment time. RESULTS: The multichannel applicator designed is able to deliver 30 Gy under 13 min with a 20350 U (5 Ci) source. The use of multiple channels and lateral shielding provide a uniform circular treatment surface with 22 mm in diameter. The resulting dose fall-off is slightly steeper (maximum difference of 5%) than the one generated by the P50 device with the 22 mm applicator. CONCLUSIONS: A novel multichannel rectal applicator for contact radiotherapy with high-dose-rate Ir-192 sources that can be integrated with commercially available treatment planning systems was designed to produce a dose distribution similar to the one obtained by the P50 device. (C) 2018 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1037 / 1044
页数:8
相关论文
共 38 条
[1]   Radiation Dose-Response Model for Locally Advanced Rectal Cancer After Preoperative Chemoradiation Therapy [J].
Appelt, Ane L. ;
Ploen, John ;
Vogelius, Ivan R. ;
Bentzen, Soren M. ;
Jakobsen, Anders .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (01) :74-80
[2]   Technical note:: Monte-Carlo dosimetry of the HDR 12i and plus 192Ir sources [J].
Ballester, F ;
Puchades, V ;
Lluch, JL ;
Serrano-Andrés, MA ;
Limami, Y ;
Pérez-Calatayud, J ;
Casal, E .
MEDICAL PHYSICS, 2001, 28 (12) :2586-2591
[3]   Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons [J].
Ballester, Facundo ;
Granero, Domingo ;
Perez-Calatayud, Jose ;
Melhus, Christopher S. ;
Rivard, Mark J. .
MEDICAL PHYSICS, 2009, 36 (09) :4250-4256
[4]   Endocavitary contact radiation therapy for ultrasonographically staged T1 N0 and T2 N0 rectal cancer [J].
Christoforidis, D. ;
McNally, M. P. ;
Jarosek, S. L. ;
Madoff, R. D. ;
Finne, C. O. .
BRITISH JOURNAL OF SURGERY, 2009, 96 (04) :430-436
[5]  
Chu S.Y.F., 1999, Table of Radioactive Isotopes, Database Version 2.0
[6]   Treatment of T1-T2 rectal tumors by contact therapy and interstitial brachytherapy [J].
Coatmeur, O ;
True, G ;
Barillot, I ;
Horiot, JC ;
Maingon, P .
RADIOTHERAPY AND ONCOLOGY, 2004, 70 (02) :177-182
[7]   Contact radiotherapy using a 50 kV X-ray system: Evaluation of relative dose distribution with the Monte Carlo code PENELOPE and comparison with measurements [J].
Croce, Olivier ;
Hachem, Sabet ;
Franchisseur, Eric ;
Marcie, Serge ;
Gerard, Jean-Pierre ;
Bordy, Jean-Marc .
RADIATION PHYSICS AND CHEMISTRY, 2012, 81 (06) :609-617
[8]   The radiobiology of Papillon-type treatments [J].
Dale, R. G. .
CLINICAL ONCOLOGY, 2007, 19 (09) :649-654
[9]   Image-guided high dose rate endorectal brachytherapy [J].
Devic, Slobodan ;
Vuong, Te ;
Moftah, Belal ;
Evans, Michael ;
Podgorsak, Ervin B. ;
Poon, Emily ;
Verhaegen, Frank .
MEDICAL PHYSICS, 2007, 34 (11) :4451-4458
[10]   A Randomized Multicenter trial to compare long-term functional outcome, quality of life, and complications of surgical procedures for low rectal cancers [J].
Fazio, Victor W. ;
Zutshi, Massarat ;
Remzi, Feza H. ;
Parc, Yann ;
Ruppert, Reinhard ;
Ffirst, Alois ;
Celebrezze, James, Jr. ;
Galanduik, Susan ;
Orangio, Guy ;
Hyman, Neil ;
Bokey, Leslie ;
Tiret, Emmanuel ;
Kirchdorfer, Boris ;
Medich, David ;
Tietze, Marcus ;
Hull, Tracy ;
Hammel, Jeff .
ANNALS OF SURGERY, 2007, 246 (03) :481-490