System calibration and statistical image reconstruction for ultra-high resolution stationary pinhole SPECT

被引:74
作者
van der Have, Frans [1 ,2 ,3 ,4 ]
Vastenhouw, Brendan [1 ,2 ]
Rentmeester, Mart [1 ,2 ]
Beekman, Freek J. [1 ,2 ,3 ,4 ]
机构
[1] Univ Med Ctr, Image Sci Inst, Dept Nucl Med, NL-3584 CG Utrecht, Netherlands
[2] Univ Med Ctr, Rudolf Magnus Inst Neurosci, Dept Pharmacol & Anat, NL-3584 CG Utrecht, Netherlands
[3] Milabs B V, NL-3584 Utrecht, Netherlands
[4] Delft Univ Technol, Sect Radiat Detect & Matter, Delft, Netherlands
关键词
calibration; pinhole; reconstruction; single-photon emission computed tomography (SPECT);
D O I
10.1109/TMI.2008.924644
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
For multipinhole single-photon emission computed tomography (SPECT), iterative reconstruction algorithms are preferred over analytical methods, because of the often complex multipinhole geometries and the ability of iterative algorithms to compensate for effects like spatially variant sensitivity and resolution. Ideally, such compensation methods are based on accurate knowledge of the position-dependent point spread functions (PSFs) specifying the response of the detectors to a point source at every position in the instrument. This paper describes a method for model-based generation of complete PSF lookup tables from a limited number of point-source measurements for stationary SPECT systems and its application to a submillimeter resolution stationary small-animal SPECT system containing 75 pinholes (U-SPECT-I). The method is based on the generalization over the entire object to be reconstructed, of a small number of properties of point-source responses which are obtained at a limited number of measurement positions. The full shape of measured point-source responses can almost be preserved in newly created PSF tables. We show that these PSFs can be used to obtain high-resolution SPECT reconstructions: the reconstructed resolutions judged by rod visibility in a micro-Derenzo phantom are 0.45 mm with 0.6-mm pinholes and below 0.35 mm with 0.3-mm pinholes. In addition, we show that different approximations, such as truncating the PSF kernel, with significant reduction of reconstruction time, can still lead to acceptable reconstructions.
引用
收藏
页码:960 / 971
页数:12
相关论文
共 47 条
[1]   Analytic determination of the resolution-equivalent effective diameter of a pinhole collimator [J].
Accorsi, R ;
Metzler, SD .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (06) :750-763
[2]   Scatter compensation methods in 3D iterative SPECT reconstruction: A simulation study [J].
Beekman, FJ ;
Kamphuis, C ;
Frey, EC .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (08) :1619-1632
[3]  
Beekman FJ, 2005, J NUCL MED, V46, P1194
[4]   Design and simulation of a high-resolution stationary SPECT system for small animals [J].
Beekman, FJ ;
Vastenhouw, B .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (19) :4579-4592
[5]  
BEEKMAN FJ, 2001, Patent No. 1018060
[6]  
BEEKMAN FJ, 2001, Patent No. 7145153
[7]  
BEEKMAN FJ, 2002, Patent No. 02093195
[8]  
BEEKMAN FJ, 2001, Patent No. 1019666
[9]   The pinhole: gateway to ultra-high-resolution three-dimensional radionuclide imaging [J].
Beekman, Freek ;
van der Have, Frans .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (02) :151-161
[10]   Optimization of geometrical calibration in pinhole SPECT [J].
Bequé, D ;
Nuyts, J ;
Suetens, P ;
Bormans, G .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (02) :180-190