Intra- and Interlaboratory Reproducibility of Ultra Performance Liquid Chromatography-Time-of-Flight Mass Spectrometry for Urinary Metabolic Profiling

被引:36
作者
Benton, H. Paul [1 ]
Want, Elizabeth [1 ]
Keun, Hector C. [1 ]
Amberg, Alexander [2 ]
Plumb, Robert S. [3 ]
Goldfain-Blanc, Francoise [4 ]
Walther, Bernhard [4 ]
Reily, Michael D. [5 ]
Lindon, John C. [1 ]
Holmes, Elaine [1 ]
Nicholson, Jeremy K. [1 ]
Ebbels, Timothy M. D. [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Surg & Canc, Fac Med, London SW7 2AZ, England
[2] Sanofi Aventis Deutschland GmbH, DSAR Preclin Safety, Frankfurt, Germany
[3] Waters Corp, Milford, MA 01757 USA
[4] Technol Servier, F-45000 Orleans, France
[5] Bristol Myers Squibb Co, Appl & Investigat Metabon, Princeton, NJ 08543 USA
关键词
METABONOMIC ANALYSIS; HPLC-MS; EXTRACTION; STRATEGY; TOXICOLOGY; ALIGNMENT; SAMPLES;
D O I
10.1021/ac203200x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Liquid chromatography coupled to mass spectrometry (LC-MS) is a major platform in metabolic profiling but has not yet been comprehensively assessed as to its repeatability and reproducibility across multiple spectrometers and laboratories. Here we report results of a large interlaboratory reproducibility study of ultra performance (UP) LC-MS of human urine. A total of 14 stable isotope labeled standard compounds were spiked into a pooled human urine sample, which was subject to a 2- to 16-fold dilution series and run by UPLC coupled to time-of-flight MS at three different laboratories all using the same platform. In each lab, identical samples were run in two phases, separated by at least 1 week, to assess between-day reproducibility. Overall, platform reproducibility was good with median mass accuracies below 12 ppm, median retention time drifts of less than 0.73 s and coefficients of variation of intensity of less than 18% across laboratories and ionization modes. We found that the intensity response was highly linear within each run, with a median R-2 of 0.95 and 0.93 in positive and negative ionization modes. Between-day reproducibility was also high with a mean R-2 of 0.93 for a linear relationship between the intensities of ions recorded in the two phases across the laboratories and modes. Most importantly, between-lab reproducibility was excellent with median R-2 values of 0.96 and 0.98 for positive and negative ionization modes, respectively, across all pairs of laboratories. Interestingly, the three laboratories observed different amounts of adduct formation, but this did not appear to be related to reproducibility observed in each laboratory. These studies show that UPLC-MS is fit for the purpose of targeted urinary metabolite analysis but that care must be taken to optimize laboratory systems for quantitative detection due to variable adduct formation over many compound classes.
引用
收藏
页码:2424 / 2432
页数:9
相关论文
共 25 条
  • [21] Urinary metabolites of 2-bromoethanamine identified by stable isotope labelling: evidence for carbamoylation and glutathione conjugation
    Shipkova, Petia
    Vassallo, Jeffrey D.
    Aranibar, Nelly
    Hnatyshyn, Serhiy
    Zhang, Haiying
    Clayton, T. Andrew
    Cantor, Glenn H.
    Sanders, Mark
    Coen, Muireann
    Lindon, John C.
    Holmes, Elaine
    Nicholson, Jeremy K.
    Lehman-McKeeman, Lois
    [J]. XENOBIOTICA, 2011, 41 (02) : 144 - 154
  • [22] XCMS: Processing mass spectrometry data for metabolite profiling using Nonlinear peak alignment, matching, and identification
    Smith, CA
    Want, EJ
    O'Maille, G
    Abagyan, R
    Siuzdak, G
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (03) : 779 - 787
  • [23] Ultra Performance Liquid Chromatography-Mass Spectrometry Profiling of Bile Acid Metabolites in Biofluids: Application to Experimental Toxicology Studies
    Want, Elizabeth J.
    Coen, Muireann
    Masson, Perrine
    Keun, Hector C.
    Pearce, Jake T. M.
    Reily, Michael D.
    Robertson, Donald G.
    Rohde, Cynthia M.
    Holmes, Elaine
    Lindon, John C.
    Plumb, Robert S.
    Nicholson, Jeremy K.
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (12) : 5282 - 5289
  • [24] An inter-laboratory comparison demonstrates that [1H]-NMR metabolite fingerprinting is a robust technique for collaborative plant metabolomic data collection
    Ward, Jane L.
    Baker, John M.
    Miller, Sonia J.
    Deborde, Catherine
    Maucourt, Mickael
    Biais, Benoit
    Rolin, Dominique
    Moing, Annick
    Moco, Sofia
    Vervoort, Jacques
    Lommen, Arjen
    Schaefer, Hartmut
    Humpfer, Eberhard
    Beale, Michael H.
    [J]. METABOLOMICS, 2010, 6 (02) : 263 - 273
  • [25] High resolution "Ultra performance" liquid chromatography coupled to oa-TOF mass spectrometry as a tool for differential metabolic pathway profiling in functional genomic studies
    Wilson, ID
    Nicholson, JK
    Castro-Perez, J
    Granger, JH
    Johnson, KA
    Smith, BW
    Plumb, RS
    [J]. JOURNAL OF PROTEOME RESEARCH, 2005, 4 (02) : 591 - 598