Intra- and Interlaboratory Reproducibility of Ultra Performance Liquid Chromatography-Time-of-Flight Mass Spectrometry for Urinary Metabolic Profiling

被引:36
作者
Benton, H. Paul [1 ]
Want, Elizabeth [1 ]
Keun, Hector C. [1 ]
Amberg, Alexander [2 ]
Plumb, Robert S. [3 ]
Goldfain-Blanc, Francoise [4 ]
Walther, Bernhard [4 ]
Reily, Michael D. [5 ]
Lindon, John C. [1 ]
Holmes, Elaine [1 ]
Nicholson, Jeremy K. [1 ]
Ebbels, Timothy M. D. [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Surg & Canc, Fac Med, London SW7 2AZ, England
[2] Sanofi Aventis Deutschland GmbH, DSAR Preclin Safety, Frankfurt, Germany
[3] Waters Corp, Milford, MA 01757 USA
[4] Technol Servier, F-45000 Orleans, France
[5] Bristol Myers Squibb Co, Appl & Investigat Metabon, Princeton, NJ 08543 USA
关键词
METABONOMIC ANALYSIS; HPLC-MS; EXTRACTION; STRATEGY; TOXICOLOGY; ALIGNMENT; SAMPLES;
D O I
10.1021/ac203200x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Liquid chromatography coupled to mass spectrometry (LC-MS) is a major platform in metabolic profiling but has not yet been comprehensively assessed as to its repeatability and reproducibility across multiple spectrometers and laboratories. Here we report results of a large interlaboratory reproducibility study of ultra performance (UP) LC-MS of human urine. A total of 14 stable isotope labeled standard compounds were spiked into a pooled human urine sample, which was subject to a 2- to 16-fold dilution series and run by UPLC coupled to time-of-flight MS at three different laboratories all using the same platform. In each lab, identical samples were run in two phases, separated by at least 1 week, to assess between-day reproducibility. Overall, platform reproducibility was good with median mass accuracies below 12 ppm, median retention time drifts of less than 0.73 s and coefficients of variation of intensity of less than 18% across laboratories and ionization modes. We found that the intensity response was highly linear within each run, with a median R-2 of 0.95 and 0.93 in positive and negative ionization modes. Between-day reproducibility was also high with a mean R-2 of 0.93 for a linear relationship between the intensities of ions recorded in the two phases across the laboratories and modes. Most importantly, between-lab reproducibility was excellent with median R-2 values of 0.96 and 0.98 for positive and negative ionization modes, respectively, across all pairs of laboratories. Interestingly, the three laboratories observed different amounts of adduct formation, but this did not appear to be related to reproducibility observed in each laboratory. These studies show that UPLC-MS is fit for the purpose of targeted urinary metabolite analysis but that care must be taken to optimize laboratory systems for quantitative detection due to variable adduct formation over many compound classes.
引用
收藏
页码:2424 / 2432
页数:9
相关论文
共 25 条
  • [1] Correction of mass calibration gaps in liquid chromatography-mass spectrometry metabolomics data
    Benton, H. Paul
    Want, Elizabeth J.
    Ebbels, Timothy M. D.
    [J]. BIOINFORMATICS, 2010, 26 (19) : 2488 - 2489
  • [2] Accurate Mass Measurement: Terminology and Treatment of Data
    Brenton, A. Gareth
    Godfrey, A. Ruth
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2010, 21 (11) : 1821 - 1835
  • [3] Practical implications of some recent studies in electrospray ionization fundamentals
    Cech, NB
    Enke, CG
    [J]. MASS SPECTROMETRY REVIEWS, 2001, 20 (06) : 362 - 387
  • [4] Mechanistic Aspects and Novel Biomarkers of Responder and Non-Responder Phenotypes in Galactosamine-Induced Hepatitis
    Coen, Muireann
    Want, Elizabeth J.
    Clayton, T. Andrew
    Rhode, Cynthia M.
    Hong, Young Shick
    Keun, Hector C.
    Cantor, Glenn H.
    Metz, Alan L.
    Robertson, Donald G.
    Reily, Michael D.
    Holmes, Elaine
    Lindon, John C.
    Nicholson, Jeremy K.
    [J]. JOURNAL OF PROTEOME RESEARCH, 2009, 8 (11) : 5175 - 5187
  • [5] Variability Analysis of Human Plasma and Cerebral Spinal Fluid Reveals Statistical Significance of Changes in Mass Spectrometry-Based Metabolomics Data
    Crews, Bridgit
    Wikoff, William R.
    Patti, Gary J.
    Woo, Hin-Koon
    Kalisiak, Ewa
    Heideker, Johanna
    Siuzdak, Gary
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (20) : 8538 - 8544
  • [6] Assessment of analytical reproducibility of 1H NMR spectroscopy based metabonomics for large-scale epidemiological research:: the INTERMAP study
    Dumas, ME
    Maibaum, EC
    Teague, C
    Ueshima, H
    Zhou, BF
    Lindon, JC
    Nicholson, JK
    Stamler, J
    Elliott, P
    Chan, Q
    Holmes, E
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (07) : 2199 - 2208
  • [7] Cross-Platform Comparison of Caenorhabditis elegans Tissue Extraction Strategies for Comprehensive Metabolome Coverage
    Geier, Florian M.
    Want, Elizabeth J.
    Leroi, Armand M.
    Bundy, Jacob G.
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (10) : 3730 - 3736
  • [8] Evaluation of the repeatability of ultra-performance liquid chromatography-TOF-MS for global metabolic profiling of human urine samples
    Gika, Helen G.
    Macpherson, Euan
    Theodoridis, Georgios A.
    Wilson, Ian D.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 871 (02): : 299 - 305
  • [9] Within-day reproducibility of an HPLC-MS-Based method for metabonomic analysis: Application to human urine
    Gika, Helen G.
    Theodoridis, Georgios A.
    Wingate, Julia E.
    Wilson, Ian D.
    [J]. JOURNAL OF PROTEOME RESEARCH, 2007, 6 (08) : 3291 - 3303
  • [10] Metabolic phenotyping in health and disease
    Holmes, Elaine
    Wilson, Ian D.
    Nicholson, Jeremy K.
    [J]. CELL, 2008, 134 (05) : 714 - 717