Biodegradable Implant for Tissue Repair After Glaucoma Drainage Device Surgery

被引:14
作者
Rosentreter, Andre [1 ]
Schild, Andrea M. [1 ]
Dinslage, Sven
Dietlein, Thomas S. [1 ]
机构
[1] Dept Ophthalmol, Bad Tolz, Germany
关键词
glaucoma drainage device; biodegradable implant; ologen implant; TUBE SHUNT SURGERY; CLINICAL-EXPERIENCE; VALVE; COLLAGEN; EYES;
D O I
10.1097/IJG.0b013e3182027ab0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim/Background: To report a novel technique using biodegradable material to cover exposed glaucoma tube shunts. Methods: A case report of a single patient who underwent drainage tube shunt surgery with the Baerveldt drainage device for intractable glaucoma. Four months post operation the tube became exposed through necrosis of the overlying scleral flap and conjunctiva. The defect was repaired by fixation of the tube to the sclera, with a slice of an ologen implant as a patch, covered by the adjacent conjunctiva. The patient was followed over a period of 1 year after the surgery. Results: Successful, lasting closure of the conjunctival defect was achieved without any side effects or complications. Conclusions: Erosion of the drainage tube after shunt surgery is a potentially serious problem. It can be successfully managed using a biodegradable implant as a patch before closing the conjunctiva.
引用
收藏
页码:76 / 78
页数:3
相关论文
共 17 条
[1]   A novel use of amniotic membrane in the management of tube exposure following glaucoma tube shunt surgery [J].
Ainsworth, G ;
Rotchford, A ;
Dua, HS ;
King, AJ .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (04) :417-419
[2]  
Aslanides IM, 1999, J GLAUCOMA, V8, P306
[3]   A clinical study of the Ahmed glaucoma valve implant in advanced glaucoma [J].
Ayyala, RS ;
Zurakowski, D ;
Smith, JA ;
Monshizadeh, R ;
Netland, PA ;
Richards, DW ;
Layden, WE .
OPHTHALMOLOGY, 1998, 105 (10) :1968-1976
[4]   Survival analysis for success of Molteno tube implants [J].
Broadway, DC ;
Iester, M ;
Schulzer, M ;
Douglas, GR .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (06) :689-695
[5]   Control of filtering bleb structure through tissue bioengineering: An animal model [J].
Chen, Henry Shen-Lih ;
Ritch, Robert ;
Krupin, Theodore ;
Hsu, Wei-Cherng .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (12) :5310-5314
[6]   Late-onset bacterial endophthalmitis following glaucoma drainage implantation [J].
Francis, BA ;
DiLoreto, DA ;
Chong, LP ;
Rao, N .
OPHTHALMIC SURGERY LASERS & IMAGING, 2003, 34 (02) :128-130
[7]   Efficacy of the Ahmed S2 Glaucoma Valve compared with the Baerveldt 250-mm2 Glaucoma Implant [J].
Goulet, Robert J., III ;
Phan, Anh-Danh T. ;
Cantor, Louis B. ;
WuDunn, Darrell .
OPHTHALMOLOGY, 2008, 115 (07) :1141-1147
[8]   Aqueous shunt tube erosion [J].
Heuer, DK ;
Budenz, D ;
Coleman, A .
JOURNAL OF GLAUCOMA, 2001, 10 (06) :493-496
[9]  
Hsu WC, 2000, INVEST OPHTH VIS SCI, V41, P2404
[10]   Tissue bioengineering for surgical bleb defects: an animal study [J].
Hsu, Wei-Cherng ;
Ritch, Robert ;
Krupin, Theodore ;
Chen, Henry Shen-Lih .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2008, 246 (05) :709-717