Comparison of Cobas 6500 and Iris IQ200 fully-automated urine analyzers to manual urine microscopy

被引:20
作者
Bakan, Ebubekir [1 ]
Ozturk, Nurinnisa [1 ]
Baygutalp, Nurcan Kilic [1 ]
Polat, Elif [1 ]
Akpinar, Kadriye [1 ]
Dorman, Emrullah [1 ]
Polat, Harun [1 ]
Bakan, Nuri [1 ]
机构
[1] Ataturk Univ, Dept Med Biochem, Fac Med, Erzurum, Turkey
关键词
auto-analysis; microscopy; urinalysis; FLOW CYTOMETER; SEDIMENT EXAMINATION; TEST STRIPS; URINALYSIS; UF-100; GUIDELINES; DIAGNOSIS; CHEMISTRY; DIPSTICK; SYSTEMS;
D O I
10.11613/BM.2016.040
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction: Urine screening is achieved by either automated or manual microscopic analysis. The aim of the study was to compare Cobas 6500 and Iris IQ200 urine analyzers, and manual urine microscopic analysis. Materials and methods: A total of 540 urine samples sent to the laboratory for chemical and sediment analysis were analyzed on Cobas 6500 and Iris IQ200 within 1 hour from sampling. One hundred and fifty three samples were found to have pathological sediment results and were subjected to manual microscopic analysis performed by laboratory staff blinded to the study. Spearman's and Gamma statistics were used for correlation analyses, and the McNemar test for the comparison of the two automated analyzers. Results: The comparison of Cobas u701 to the manual method yielded the following regression equations: y = -0.12 (95% CI: -1.09 to 0.67) + 0.78 (95% CI: 0.65 to 0.95) x for WBC and y = 0.06 (95% CI: -0.09 to 0.25) + 0.66 (95% CI: 0.57 to 0.73) x for RBC. The comparison of IQ200 Elite to manual method the following equations: y = 0.03 (95% CI: -1.00 to 1.00) + 0.88 (95% CI: 0.66 to 1.00) x for WBC and y = -0.22 (95% CI: -0.80 to 0.20) + 0.40 (95% CI: 0.32 to 0.50) x for RBC. IQ200 Elite compared to Cobas u701 yielded the following equations: y = -0.95 (95% CI: -2.13 to 0.11) + 1.25 (95% CI: 1.08 to 1.44) x for WBC and y = -1.20 (95% CI: -1.80 to -0.30) + 0.80 (95% CI: 0.55 to 1.00) x for RBC. Conclusions: The two analyzers showed similar performances and good compatibility to manual microscopy. However, they are still inadequate in the determination of WBC, RBC, and EC in highly-pathological samples. Thus, confirmation by manual microscopic analysis may be useful.
引用
收藏
页码:365 / 375
页数:11
相关论文
共 27 条
[1]   Comparison of LabUMat-with-UriSed and iQ®200 fully automatic urine sediment analysers with manual urine analysis [J].
Akin, Okhan Kadir ;
Serdar, Muhittin A. ;
Cizmeci, Zeynep ;
Genc, Ozlem ;
Aydin, Suleyman .
BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2009, 53 :139-144
[2]   New Generation IQ-200 Automated Urine Microscopy Analyzer Compared With KOVA Cell Chamber [J].
Altekin, Emel ;
Kadicesme, Ozgur ;
Akan, Pinar ;
Kume, Tuncay ;
Vupa, Ozgul ;
Ergor, Gul ;
Abacioglu, Hakan .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2010, 24 (02) :67-71
[3]  
[Anonymous], 2000, SCAND J CLIN LAB I S, V231, P1, DOI [10.1080/00365513.2000.12056993, DOI 10.1080/00365513.2000.12056993]
[4]   European guidelines for urinalysis: a collaborative document produced by European clinical microbiologists and clinical chemists under ECLM in collaboration with ESCMID [J].
Aspevall, O ;
Hallander, H ;
Gant, V ;
Kouri, T .
CLINICAL MICROBIOLOGY AND INFECTION, 2001, 7 (04) :173-178
[5]   Advances in Urine Microscopy [J].
Becker, Gavin J. ;
Garigali, Giuseppe ;
Fogazzi, Giovanni B. .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2016, 67 (06) :954-964
[6]  
Budak YU, 2011, CLIN LAB, V57, P47
[7]   Urine sediment examination: A comparison of automated urinalysis systems and manual microscopy [J].
Chien, Tzu-I ;
Kao, Jau-Tsuen ;
Liu, Hui-Lan ;
Lin, Po-Chang ;
Hong, Jhih-Sian ;
Hsieh, Han-Peng ;
Chien, Miao-Ju .
CLINICA CHIMICA ACTA, 2007, 384 (1-2) :28-34
[8]   Evaluation of the performances of the iQ®200 ELITE automated urine microscopy analyser and comparison with manual microscopy method [J].
Dewulf, G. ;
Harrois, D. ;
Mazars, E. ;
Cattoen, C. ;
Canis, F. .
PATHOLOGIE BIOLOGIE, 2011, 59 (05) :264-268
[9]   The automation of sediment urinalysis using a new urine flow cytometer (UF-100™) [J].
Fenili, D ;
Pirovano, B .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 1998, 36 (12) :909-917
[10]  
Fuller C.E., 2001, Clinical Diagnosis and Management by Laboratory Methods, V20th, P367