Urchinlike MnO2 nanoparticles for the direct electrochemistry of hemoglobin with carbon ionic liquid electrode

被引:70
作者
Zhu, Zhihong [2 ,3 ]
Qu, Lining [1 ]
Niu, Qingjuan [1 ]
Zeng, Yan [2 ,3 ]
Sun, Wei [1 ]
Huang, Xintang [2 ,3 ]
机构
[1] Qingdao Univ Sci & Technol, Coll Chem & Mol Engn, Qingdao 266042, Peoples R China
[2] Huazhong Normal Univ, Inst Nanosci, Wuhan 430079, Peoples R China
[3] Huazhong Normal Univ, Ctr Technol, Wuhan 430079, Peoples R China
基金
美国国家科学基金会;
关键词
Urchinlike MnO2 nanoparticle; Carbon ionic liquid electrode; Hemoglobin; Direct electrochemistry; ELECTROCATALYSIS; FILMS; PROTEIN; ACIDS;
D O I
10.1016/j.bios.2010.09.017
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this paper an urchinlike MnO2 nanoparticle was synthesized by hydrothermal method and applied to the protein electrochemistry for the first time. By using a carbon ionic liquid electrode (CILE) as the basal electrode, hemoglobin (Hb) was immobilized on the surface of CILE with chitosan (CTS) and MnO2 nanoparticle composite materials. Spectroscopic results indicated that Hb molecules retained its native structure in the composite film. A pair of well-defined redox peaks appeared on the cyclic voltammogram with the formal peak potential as -0.180 V (vs. SCE), which indicated that direct electron transfer of Hb was realized on the modified electrode. The result can be attributed to the specific characteristic of MnO2 nanoparticle and the advantages of CILE, which facilitated the electron transfer rate. The fabricated CTS-MnO2-Hb/CILE showed good electrocatalytic ability to the reduction of trichloroacetic acid (TCA). Under the optimal conditions the catalytic current was in linear to TCA concentration in the range from 0.5 to 16.0 mmol L-1 with the detection limit calculated as 0.167 mmol L-1 (3 sigma). The result indicated that urchinlike MnO2 nanoparticle had the potential application in the third generation electrochemical biosensors. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2119 / 2124
页数:6
相关论文
共 37 条
[21]   REACTIONS OF THE CARBON TETRACHLORIDE-RELATED PEROXY FREE-RADICAL (CCL3O2) WITH AMINO-ACIDS - PULSE-RADIOLYSIS EVIDENCE [J].
PACKER, JE ;
SLATER, TF ;
WILLSON, RL .
LIFE SCIENCES, 1978, 23 (26) :2617-2620
[22]   THE TREATMENT OF TATTOOS WITH TRICHLORACETIC ACID - EXPERIENCE WITH 670 PATIENTS [J].
PIGGOT, TA ;
NORRIS, RW .
BRITISH JOURNAL OF PLASTIC SURGERY, 1988, 41 (02) :112-117
[23]   Manganese dioxide graphite composite electrodes formed via a low temperature method: Detection of hydrogen peroxide, ascorbic acid and nitrite [J].
Sljukic, Biljana ;
Compton, Richard G. .
ELECTROANALYSIS, 2007, 19 (12) :1275-1280
[24]   Direct electrochemistry of single-stranded DNA on an ionic liquid modified carbon paste electrode [J].
Sun, Wei ;
Li, Yinzhuo ;
Yang, Maoxia ;
Liu, Shufeng ;
Jiao, Kui .
ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (02) :298-301
[25]   Electrochemistry and electrocatalysis of hemoglobin in nafion/nano-CaCO3 film on a new ionic liquid BPPF6 modified carbon paste electrode [J].
Sun, Wei ;
Gao, Ruifang ;
Jiao, Kui .
JOURNAL OF PHYSICAL CHEMISTRY B, 2007, 111 (17) :4560-4567
[26]   Electrodeposition of Co Nanoparticles on the Carbon Ionic Liquid Electrode as a Platform for Myoglobin Electrochemical Biosensor [J].
Sun, Wei ;
Li, Xiaoqing ;
Qin, Peng ;
Jiao, Kui .
JOURNAL OF PHYSICAL CHEMISTRY C, 2009, 113 (26) :11294-11300
[27]   Electrochemical biosensors:: Recommended definitions and classification [J].
Thévenot, DR ;
Toth, K ;
Durst, RA ;
Wilson, GS .
ANALYTICAL LETTERS, 2001, 34 (05) :635-659
[28]  
UDEN PC, 1983, J AM WATER WORKS ASS, V75, P524
[29]   Nanomaterial-based electrochemical biosensors [J].
Wang, J .
ANALYST, 2005, 130 (04) :421-426
[30]   Direct electrochemistry and electrocatalysis of heme proteins entrapped in agarose hydrogel films in room-temperature ionic liquids [J].
Wang, SF ;
Chen, T ;
Zhang, ZL ;
Shen, XC ;
Lu, ZX ;
Pang, DW ;
Wong, KY .
LANGMUIR, 2005, 21 (20) :9260-9266