Polyethylene insert exchange for wear after toad shoulder arthroplasty

被引:25
作者
Cheung, Emilie V. [1 ]
Sperling, John W. [1 ]
Cofield, Robert H. [1 ]
机构
[1] Mayo Clin, Dept Orthoped Surg, Rochester, MN USA
关键词
D O I
10.1016/j.jse.2006.12.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Virtually no information is available in the literature to guide clinical decision-making in regard to modular polyethylene exchange with metal-backed glenoid components in total shoulder arthroplasty for the indication of polyethylene wear. This level IV study reports our experience with exchange of the modular polyethylene glenoid component during revision total shoulder arthroplasty. We retrospectively identified 12 shoulders in 11 patients who underwent exchange of the modular polyethylene glenoid component during revision arthroplasty. The primary reason for revision orthroplasty with polyethylene exchange was wear-through or displacement of the polyethylene portion of ' the glenoid component, but rotator cuff tearing and instability often coexisted. The average follow-up from time of revision to latest evaluation or repeat revision arthroplasty was 68 months. Preoperative pain was a mean of 4.5 (range, 4-5), and postoperative pain was a mean of 2.6 (range, 1-5). Preoperative average active forward elevation was 93 degrees, and external rotation ' was 51 degrees. Postoperative active forward elevation was 89 degrees, and external rotation was 64 degrees. Average patient satisfaction was rated as the same. According to the modified Neer rating system, 4 shoulders (33%) had a satisfactory result, and 8 (62%) had an unsatisfactory result. Polyethylene exchange of glenoid component ' after total shoulder arthroplasty can be an effective treatment option in patients who do not have coexistent rotator cuff tear or instability. For most, instability, rotator cuff tear, and glenoid wear occur together, and this is a challenging problem to treat successfully.
引用
收藏
页码:574 / 578
页数:5
相关论文
共 13 条
[1]   The effectiveness of isolated tibial insert exchange in revision total knee arthroplasty [J].
Babis, GC ;
Trousdale, RT ;
Morrey, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (01) :64-68
[2]   The incidence of modular tibial polyethylene insert exchange in total knee arthroplasty when polyethylene failure occurs [J].
Bert, JM ;
Reuben, J ;
Kelly, F ;
Gross, M ;
Elting, J .
JOURNAL OF ARTHROPLASTY, 1998, 13 (06) :609-614
[3]   TOTAL SHOULDER ARTHROPLASTY WITH THE NEER PROSTHESIS [J].
COFIELD, RH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (06) :899-906
[4]   Success rate of modular component exchange for the treatment of an unstable total hip arthroplasty [J].
Earll, MD ;
Fehring, TK ;
Griffin, WL ;
Mason, JB ;
McCoy, T ;
Odum, S .
JOURNAL OF ARTHROPLASTY, 2002, 17 (07) :864-869
[5]   Clinical results of modular polyethylene insert exchange with retention of total knee arthroplasty components [J].
Engh, GA ;
Koralewicz, LM ;
Pereles, TR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (04) :516-523
[6]  
Franklin J L, 1988, J Arthroplasty, V3, P39, DOI 10.1016/S0883-5403(88)80051-2
[7]   Influence of preoperative factors on outcome of shoulder arthroplasty for glenohumeral osteoarthritis [J].
Iannotti, JP ;
Norris, TR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (02) :251-258
[8]   Modular revision for recurrent dislocation of primary or revision total hip arthroplasty [J].
Lachiewicz, PF ;
Soileau, E ;
Ellis, J .
JOURNAL OF ARTHROPLASTY, 2004, 19 (04) :424-429
[9]   Polyethylene wear after total elbow arthroplasty [J].
Lee, BP ;
Adams, RA ;
Morrey, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (05) :1080-1087
[10]   RECENT EXPERIENCE IN TOTAL SHOULDER REPLACEMENT [J].
NEER, CS ;
WATSON, KC ;
STANTON, FJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (03) :319-337