Accuracy of thoracic aortic measurements assessed by contrast enhanced and unenhanced magnetic resonance imaging

被引:26
作者
Groth, M. [1 ]
Henes, F. O. [1 ]
Muellerleile, K. [2 ]
Bannas, P. [1 ]
Adam, G. [1 ]
Regier, M. [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Diagnost & Intervent Radiol, Ctr Radiol & Endoscopy, D-20246 Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Gen & Intervent Cardiol, Ctr Cardiol & Cardiovasc Surg, D-20246 Hamburg, Germany
关键词
Thoracic aorta; Magnetic resonance imaging; Steady-state free precession; Contrast media; STATE FREE-PRECESSION; NEPHROGENIC SYSTEMIC FIBROSIS; MR-ANGIOGRAPHY; SSFP; DISSECTION; AGENTS; CT;
D O I
10.1016/j.ejrad.2011.01.071
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: To assess, whether unenhanced balanced steady-state-free precession sequences provide axial thoracic aortic measurements comparable to contrast enhanced magnetic resonance angiography with good intra-and interobserver agreement. Materials and methods: Enhanced and unenhanced sequences of the thoracic aorta in 23 consecutive patients were evaluated. Axial thoracic aortic diameters were measured at predefined levels by two independent readers. Pearson's correlation coefficient and Bland-Altman analysis were used to compare enhanced and unenhanced sequences. t-Test was used to determine possible significant differences between the measurements obtained by enhanced and unenhanced sequences. A p-value of less than .05 indicated statistical significance. Intraclass correlation coefficient and Bland-Altman were used for inter-and intraobserver correlation and agreement. Results: There was no significant difference in diameter measurements between enhanced and unenhanced sequences (ascending aorta, p = 0.98; descending aorta, p = 0.52). Bland-Altman revealed good agreement between enhanced and unenhanced sequences for ascending (mean bias, -0.01 cm; with 95% limits of agreement, +/-0.30 cm) and descending aortic diameters (mean bias, 0.05 cm; with 95% limits of agreement, +/-0.30 cm). Inter-and intraobserver agreement (mean bias, less than +/-0.15; with 95% limits of agreement, less than +/-0.42 cm for all measurements) as well as correlation (r > 0.8 for all measurements) were excellent. Conclusion: Unenhanced balanced steady-state-free precession sequences enable rapid and accurate determination of axial thoracic aortic diameters with excellent inter-and intraobserver agreement, but without the risk of contrast media associated side-effects. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:762 / 766
页数:5
相关论文
共 20 条
[1]   Nephrogenic systemic fibrosis associated with gadolinium based contrast agents: A summary of the medical literature reporting [J].
Broome, Dale R. .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 66 (02) :230-234
[2]   Diagnosis and management of aortic dissection - Recommendations of the Task Force on Aortic Dissection, European Society of Cardiology [J].
Erbel, R ;
Alfonso, F ;
Boileau, C ;
Dirsch, O ;
Eber, B ;
Haverich, A ;
Rakowski, H ;
Struyven, J ;
Radegran, K ;
Sechtem, U ;
Taylor, J ;
Zollikofer, C ;
Klein, WW ;
Mulder, B ;
Providencia, LA .
EUROPEAN HEART JOURNAL, 2001, 22 (18) :1642-1681
[3]   Unenhanced MR angiography of the thoracic aorta:: Initial clinical evaluation [J].
Francois, Christopher J. ;
Tuite, David ;
Deshpande, Vibhas ;
Jerecic, Renate ;
Weale, Peter ;
Carr, James C. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (04) :902-906
[4]   Comparison of different MRI techniques for the assessment of thoracic aortic pathology: 3D contrast enhanced MR angiography, turbo spin echo and balanced steady state free precession [J].
Gebker, Rolf ;
Gomaa, Osama ;
Schnackenburg, Bernhard ;
Rebakowski, Janina ;
Fleck, Eckart ;
Nagel, Eike .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2007, 23 (06) :747-756
[5]   Intraindividual Comparison of Contrast-Enhanced MRI and Unenhanced SSFP Sequences of Stenotic and Non-stenotic Pulmonary Artery Diameters [J].
Groth, M. ;
Henes, F. O. ;
Bannas, P. ;
Muellerleile, K. ;
Adam, G. ;
Regier, M. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2011, 183 (01) :47-53
[6]   Multicenter Analysis of Tolerance and Clinical Safety of the Extracellular MR Contrast Agent Gadobenate Dimeglumine (MultiHance®) [J].
Herborn, C. U. ;
Jaeger-Booth, I. ;
Lodemann, K. P. ;
Spinazzi, A. ;
Goyen, M. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2009, 181 (07) :652-657
[7]   The value of true-FISP sequence added to conventional gadolinium-enhanced MRA of abdominal aorta and its major branches [J].
Iozzelli, Andrea ;
D'Orta, Giovanni ;
Aliprandi, Alberto ;
Secchi, Francesco ;
Di Leo, Giovanni ;
Sardanelli, Francesco .
EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (03) :489-493
[8]   Thoracoabdominal aorta in Marfan syndrome: MR imaging findings of progression of vasculopathy after surgical repair [J].
Kawamoto, S ;
Bluemke, DA ;
Traill, TA ;
Zerhouni, EA .
RADIOLOGY, 1997, 203 (03) :727-732
[9]   Dark-blood MRI of the thoracic aorta with 3D diffusion-prepared steady-state free precession: Initial clinical evaluation [J].
Koktzoglou, Loannis ;
Kirpalani, Anish ;
Carroll, Timothy J. ;
Li, Debiao ;
Carr, James C. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (04) :966-972
[10]   Contrast-enhanced three-dimensional MR angiography of the thoracic aorta:: experiences after 118 examinations with a standard dose contrast administration and different injection protocols [J].
Kreitner, KF ;
Kunz, RP ;
Kalden, P ;
Kauczor, HU ;
Schmitt, S ;
Kuroczynski, W ;
Mohr-Kahaly, S ;
Voightländer, T ;
Krummenauer, F ;
Laub, G ;
Thelen, M .
EUROPEAN RADIOLOGY, 2001, 11 (08) :1355-1363