Analysis of intact erythropoietin and novel erythropoiesis-stimulating protein by capillary electrophoresis-electrospray-ion trap mass spectrometry

被引:44
作者
Gimenez, Estela [1 ]
Benavente, Fernando [1 ]
Barbosa, Jose [1 ]
Sanz-Nebot, Victoria [1 ]
机构
[1] Univ Barcelona, Dept Quim Analit, E-08028 Barcelona, Spain
关键词
capillary electrophoresis-mass spectrometry; coating; contamination; erythropoietin; novel erythropoiesis-stimulating protein;
D O I
10.1002/elps.200700788
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Recombinant human erythropoietin (rHuEPO) and novel erythropoiesis-stimulating protein (NESP) were analyzed by CE-ESI-MS using an IT as analyzer. The IT parameters were optimized by direct infusion of solutions of different intact proteins (myoglobin, transferrin, a,-acid glycoprotein and fetuin) with different degrees of glycosylation (from 0 to 35% w/w). Two physically adsorbed capillary coatings from UltraTol (TM) Pre-Coats (low normal (LN) and high reverse (HR)) were evaluated for the separation of rHuEPO and NESP glycoforms by CE-ESI-IT-MS. The results obtained with the neutral LN coating suggest that an IT mass spectrometer enables identification of the main glycoforms of a complex glycoprotein such as rHuEPO. Although LN provided acceptable glycoform resolution for rHuEPO, the separation obtained for NESP was less significant due to the higher microheterogeneity of this glycoprotein. Reproducibility studies confirmed the lack of stability and bleeding of the LN coating, which caused problems with MS detection, such as a dramatic loss of sensitivity and the presence of peaks in the mass spectra corresponding to molecular ions in the coating. in contrast, the cationic H R coating gave faster but poorer glycoform. separations due to the presence of an anodal EOF. However, the positive charge of the coating provided enhanced hydrolytic stability, making it more suitable than the LN coating for the on-line MS coupling.
引用
收藏
页码:2161 / 2170
页数:10
相关论文
共 22 条
[1]   Glycoform characterization of erythropoietin combining glycan and intact protein analysis by capillary electrophoresis electrospray time-of-flight mass spectrometry [J].
Balaguer, Elvira ;
Demelbauer, Uwe ;
Pelzing, Matthias ;
Sanz-Nebot, Victoria ;
Barbosa, Jose ;
Neusuess, Christian .
ELECTROPHORESIS, 2006, 27 (13) :2638-2650
[2]   Glycoprotein characterization combining intact protein and glycan analysis by capillary electrophoresis-electrospray ionization-mass spectrometry [J].
Balaguer, Elvira ;
Neusuess, Christian .
ANALYTICAL CHEMISTRY, 2006, 78 (15) :5384-5393
[3]   Assessing the instability of the isoelectric focusing patterns of erythropoietin in urine [J].
Belalcazar, Viviana ;
Gallego, Ricardo Gutierrez ;
Llop, Esther ;
Segura, Jordi ;
Pascual, Jose Antonio .
ELECTROPHORESIS, 2006, 27 (22) :4387-4395
[4]  
BRISTOW A, 2002, EUR PHARMACOPOEIA, V4, P1123
[5]   Strategies to study human serum transferrin isoforms using integrated liquid chromatography ICPMS, MALDI-TOF, and ESI-Q-TOF detection:: Application to chronic alcohol abuse [J].
Busto, MED ;
Montes-Bayón, M ;
Blanco-González, E ;
Meija, J ;
Sanz-Medel, A .
ANALYTICAL CHEMISTRY, 2005, 77 (17) :5615-5621
[6]  
Chang WWP, 2005, AM LAB, V37, P25
[7]   Darbepoetin alfa has a longer circulating half-life and greater in vivo potency than recombinant human erythropoietin [J].
Egrie, JC ;
Dwyer, E ;
Browne, JK ;
Hitz, A ;
Lykos, MA .
EXPERIMENTAL HEMATOLOGY, 2003, 31 (04) :290-299
[8]   Development and characterization of novel erythropoiesis stimulating protein (NESP) [J].
Egrie, JC ;
Browne, JK .
BRITISH JOURNAL OF CANCER, 2001, 84 (Suppl 1) :3-10
[9]  
Fisher JW, 2003, EXP BIOL MED, V228, P1
[10]   Capillary electrophoresis-mass spectrometry for the analysis of intact proteins [J].
Haselberg, Rob ;
de Jong, Gerhardus J. ;
Somsen, Govert W. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1159 (1-2) :81-109