Scanning laser polarimetry of nerve fiber layer thickness in normal eyes after cataract phacoemulsification and foldable intraocular lens implantation

被引:5
作者
Iacono, P [1 ]
Da Pozzo, S [1 ]
Vattovani, O [1 ]
Tognetto, D [1 ]
Ravalico, G [1 ]
机构
[1] Univ Trieste, Eye Clin, I-34129 Trieste, Italy
关键词
D O I
10.1016/j.jcrs.2004.09.054
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the effect of cataract phacoemulsification and intraocular lens (IOL) implantation on retinal nerve fiber layer (RNFL) thickness using scanning laser polarimetry (SLP). Setting: Eye Clinic, Trieste University, Italy. Methods: Forty-eight eyes were evaluated prospectively the day before and 30 days after cataract phacoemulsification and foldable IOL implantation. In each eye, lens opacity grading according to the Lens Opacities Classification System III (LOCS III), and axial length (AL) measurements were performed. Retinal nerve fiber layer thickness was quantified at baseline by means of SLP and anterior segment birefringence compensation was evaluated acquiring macular retardation map (MRM). Acrylic and silicone IOLs were implanted randomly. After surgery, RNFL thickness was reevaluated, and MRM was reacquired. Macular retardation map pattern variations regarding baseline profile were classified into 3 groups: no variation, bow-tie profile enhancement, or attenuation. Distribution of IOL power, AL, and cataract type in the 3 groups was assessed, as were presurgery and postsurgery SLP parameters with mean values (+/- SD) compared by paired t test. Results: Twenty-two eyes (Group 1, 45.8%) showed no MRM variation, 14 (Group 2, 29.2%) an enhancement, and 12 (Group 3, 25%) an attenuation. In Group 1, no significant RNFL thickness variation occurred. In Group 2, variation 10% to 15% was measured, whereas thickening a 8% to 15% thinning appeared in Group 3. Variations occurred irrespective of IOL material, AL, or cataract type. Conclusions: Cataract surgery with IOL implantation was associated with an MRM profile change and RNFL thickness variations in 54.2% of eyes. Variations are probably related to opacified lens removal. A new baseline SLP reading is mandatory after cataract surgery. (c) 2005 ASCRS and ESCRS.
引用
收藏
页码:1042 / 1049
页数:8
相关论文
共 24 条
[1]   Scanning laser polarimetry with variable corneal compensation: Identification and correction for corneal birefringence in eyes with macular disease [J].
Bagga, H ;
Greenfield, DS ;
Knighton, RW .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (05) :1969-1976
[2]   MACULAR PIGMENT IN HENLE FIBER MEMBRANES - A MODEL FOR HAIDINGER BRUSHES [J].
BONE, RA ;
LANDRUM, JT .
VISION RESEARCH, 1984, 24 (02) :103-108
[3]  
BOUR LJ, 1991, VISUAL OPTICS INSTRU, V1, P310
[4]   BIREFRINGENCE OF THE HUMAN FOVEAL AREA ASSESSED INVIVO WITH MUELLER-MATRIX ELLIPSOMETRY [J].
BRINK, HBK ;
VANBLOKLAND, GJ .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1988, 5 (01) :49-57
[5]   Polarization properties of the in vitro old human crystalline lens [J].
Bueno, JM ;
Campbell, MCW .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2003, 23 (02) :109-118
[6]  
Chiba Tatsuya, 2000, Nippon Ganka Gakkai Zasshi, V104, P626
[7]   Effect of individualized compensation for anterior segment birefringence on retinal nerve fiber layer assessments as determined by scanning laser polarimetry [J].
Choplin, NT ;
Zhou, QY ;
Knighton, RW .
OPHTHALMOLOGY, 2003, 110 (04) :719-725
[8]   THE LENS OPACITIES CLASSIFICATION SYSTEM-III [J].
CHYLACK, LT ;
WOLFE, JK ;
SINGER, DM ;
LESKE, MC ;
BULLIMORE, MA ;
BAILEY, IL ;
FRIEND, J ;
MCCARTHY, D ;
WU, SY .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (06) :831-836
[9]  
Collur S, 2000, OPHTHALMIC SURG LAS, V31, P126
[10]   SPATIALLY RESOLVED BIREFRINGENCE OF THE RETINAL NERVE-FIBER LAYER ASSESSED WITH A RETINAL LASER ELLIPSOMETER [J].
DREHER, AW ;
REITER, K ;
WEINREB, RN .
APPLIED OPTICS, 1992, 31 (19) :3730-3735