Utilization of wavelength-shifting fibers coupled to ZnS(Ag) and plastic scintillator for simultaneous detection of alpha/beta particles

被引:6
作者
Ifergan, Y. [1 ]
Dadon, S. [1 ]
Israelashvili, I. [2 ]
Osovizky, A. [3 ]
Gonen, E. [1 ]
Yehuda-Zada, Y. [1 ]
Smadja, D. [1 ]
Knafo, Y. [3 ]
Ginzburg, D. [3 ]
Kadmon, Y. [1 ]
Cohen, Y. [1 ]
Mazor, T. [1 ]
机构
[1] Nucl Res Ctr Negev, Elect & Control Labs, IL-84190 Beer Sheva, Israel
[2] Nucl Res Ctr Negev, Dept Phys, IL-84190 Beer Sheva, Israel
[3] Rotem Ind Ltd, Radiat Detect Dept, Beer Sheva, Israel
关键词
Wavelength shifting (WLS) fiber; ZnS(Ag); Plastic scintillator;
D O I
10.1016/j.nima.2014.11.049
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Low level radioactive surface contamination measurements require lightweight, large area and high efficiency detector. In most existing scintillation detectors there is a tradeoff between effective area and scintillation light collection. By using wavelength shifting (WLS) fibers the scintillation light may be collected efficiently also in a large area detector. In this study, WLS fibers were coupled to a beta sensitive plastic scintillator layer and to a alpha sensitive silver-activated zinc sulfide ZnS(Ag) layer for detecting both alpha and beta particles. The WLS fibers collect the scintillation light from the whole detector and transfer it to a single PMT. This first prototype unique configuration enables monitoring radioactive contaminated surfaces by both sides of the detector and provides high gamma rejection. In this paper, the detector structure, as well as the detector's measured linear response, will be described. The measured detection efficiency of (PU)-P-238 alpha particles (5.5 MeV) is similar to 63%. The measured detection efficiency for beta particles is similar to 89% for Sr-90-Y-90 (average energy of 195.8 key, 934.8 key), similar to 50% for (CI)-C-36 (average energy of 251.3 key), and 35% for Cs-137 (average energy of 156.8 keV). (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:93 / 96
页数:4
相关论文
共 7 条
[1]  
Bugg W., 2013, OPTIMIZATION CO 1204
[2]   Scintillation counter with WLS fiber readout [J].
Bukin, DA ;
Druzhinin, VP ;
Golubev, VB ;
Serednyakov, SI .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 384 (2-3) :360-363
[3]   MCNP analysis and optimization of a triple crystal phoswich detector [J].
Childress, NL ;
Miller, WH .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 490 (1-2) :263-270
[4]  
Knoll G.F., 1989, Radiation Detection and Measurement, V2nd
[5]   Extruded plastic counters with WLS fiber readout [J].
Kudenko, YG ;
Littenberg, LS ;
Mayatski, VA ;
Mineev, OV ;
Yershov, NV .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 469 (03) :340-346
[6]  
Seung Kyu L.E.E., 2011, NUCL SCI TECHNOLOGY, V1, P194
[7]  
Tatsuyuki M., 1998, NUCL SCI TECHNOLOGY, V35, P886