Fitting the Two-Compartment Model in DCE-MRI by Linear Inversion

被引:21
作者
Flouri, Dimitra [1 ,2 ]
Lesnic, Daniel [2 ]
Sourbron, Steven P. [1 ]
机构
[1] Univ Leeds, Div Biomed Imaging, Leeds LS2 9JT, W Yorkshire, England
[2] Univ Leeds, Dept Appl Math, Leeds LS2 9JT, W Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
Dynamic Contrast-Enhanced Magnetic Resonance Imaging; tracer-kinetics; two-compartment model; linear least squares; non-linear least-squares; CONTRAST-ENHANCED MRI; PARAMETER-ESTIMATION; KINETIC-PARAMETERS; PHARMACOKINETIC PARAMETERS; GLOMERULAR-FILTRATION; COMPARTMENT MODEL; PERFUSION; PERMEABILITY; BRAIN; ALGORITHMS;
D O I
10.1002/mrm.25991
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Model fitting of dynamic contrast-enhanced-magnetic resonance imaging-MRI data with nonlinear least squares (NLLS) methods is slow and may be biased by the choice of initial values. The aim of this study was to develop and evaluate a linear least squares (LLS) method to fit the two-compartment exchange and -filtration models. Methods: A second-order linear differential equation for the measured concentrations was derived where model parameters act as coefficients. Simulations of normal and pathological data were performed to determine calculation time, accuracy and precision under different noise levels and temporal resolutions. Performance of the LLS was evaluated by comparison against the NLLS. Results: The LLS method is about 200 times faster, which reduces the calculation times for a 256 x 256 MR slice from 9 min to 3 s. For ideal data with low noise and high temporal resolution the LLS and NLLS were equally accurate and precise. The LLS was more accurate and precise than the NLLS at low temporal resolution, but less accurate at high noise levels. Conclusion: The data show that the LLS leads to a significant reduction in calculation times, and more reliable results at low noise levels. At higher noise levels the LLS becomes exceedingly inaccurate compared to the NLLS, but this may be improved using a suitable weighting strategy. (C) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:998 / 1006
页数:9
相关论文
共 31 条
[1]   Model-based registration for dynamic cardiac perfusion MRI [J].
Adluru, Ganesh ;
DiBella, Edward V. R. ;
Schabel, Matthias C. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (05) :1062-1070
[2]   The use of the Levenberg-Marquardt curve-fitting algorithm in pharmacokinetic modelling of DCE-MRI data [J].
Ahearn, TS ;
Staff, RT ;
Redpath, TW ;
Semple, SIK .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (09) :N85-N92
[3]   Glomerular filtration rate: Assessment with dynamic contrast-enhanced MRI and a cortical-compartment model in the rabbit kidney [J].
Annet, L ;
Hermoye, L ;
Peeters, F ;
Jamar, F ;
Dehoux, JP ;
Van Beers, BE .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (05) :843-849
[4]  
Banks H. T., 2007, Journal of Inverse and ILL-Posed Problems, V15, P683, DOI 10.1515/JIIP.2007.038
[5]   Microcirculation and microvasculature in breast tumors: Pharmacokinetic analysis of dynamic MR image series [J].
Brix, G ;
Kiessling, F ;
Lucht, R ;
Darai, S ;
Wasser, K ;
Delorme, S ;
Griebel, J .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (02) :420-429
[6]   Generalized linear least squares algorithms for modeling glucose metabolism in the human brain with corrections for vascular effects [J].
Cai, WD ;
Feng, DG ;
Fulton, R ;
Siu, WC .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2002, 68 (01) :1-14
[7]  
Cardenas-Rodriguez J, 2013, J MAGN RESON IMAGING, V31, P497
[8]   Extended Graphical Model for Analysis of Dynamic Contrast-Enhanced MRI [J].
Chen, Huijun ;
Li, Feiyu ;
Zhao, Xihai ;
Yuan, Chun ;
Rutt, Brian ;
Kerwin, William S. .
MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (03) :868-878
[9]   Generalized linear least squares method for fast generation of myocardial blood flow parametric images with N-13 ammonia PET [J].
Chen, KW ;
Lawson, M ;
Reiman, E ;
Cooper, A ;
Feng, DG ;
Huang, SC ;
Bandy, D ;
Ho, D ;
Yun, LS ;
Palant, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (02) :236-243
[10]   Performance evaluation of kinetic parameter estimation methods in dynamic FDG-PET studies [J].
Dai, Xiaoqian ;
Chen, Zhe ;
Tian, Jie .
NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (01) :4-16