Accuracy of computer-assisted orthognathic surgery

被引:65
作者
De Riu, Giacomo [1 ]
Virdis, Paola Ilaria [1 ]
Meloni, Silvio Mario [2 ]
Lumbau, Aurea [2 ]
Vaira, Luigi Angelo [1 ]
机构
[1] Univ Sassari Hosp Head Dott Giacomo De Riu, Maxillofacial Surg Operat Unit, Viale San Pietro 43B, I-07100 Sassari, Italy
[2] Univ Sassari Hosp Head Prof Edoardo Baldoni, Dent Sch, Viale San Pietro 43B, I-07100 Sassari, Italy
关键词
Orthognathic surgery; Virtual surgical planning; Computer-assisted orthognathic surgery; Virtual planning accuracy; FACE-BOW TRANSFER; CAD/CAM SURGICAL SPLINTS; SIMULATION; PREDICTION; EXPERIENCE;
D O I
10.1016/j.jcms.2017.11.023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this study was to retrospectively evaluate the difference between the planned and the actual movements of the jaws, using three-dimensional (3D) software for PC-assisted orthognathic surgery, to establish the accuracy of the procedure. Material and methods: A retrospective study was performed with 49 patients who had undergone PC-guided bimaxillary surgery. The accuracy of the protocol was determined by comparing planned movements of the jaws with the actual surgical movements, analysing frontal and lateral cephalometries. Results: The overall results were deemed accurate, and differences among 12 of the 15 parameters were considered nonsignificant. Significant differences were reported for SNA (p = 0.008), SNB (p = 0.006), and anterior facial height (p = 0.033). The latter was significantly different in patients who had undergone genioplasty when compared with patients who had not. Conclusion: Virtual surgical planning presented a good degree of accuracy for most of the parameters assessed, with an average error of 1.98 mm for linear measures and 1.19 degrees for angular measures. In general, a tendency towards under-projection in jaws was detected, probably due to imperfect condylar seating. A slight overcorrection of SNA and SNB during virtual planning (approximately 2 degrees) could be beneficial. Further progress is required in the development of 3D simulation of the soft tissue, which currently does not allow an accurate management of the facial height and the chin position. Virtual planning cannot replace the need for constant intraoperative monitoring of the jaws' movements and real-time comparisons between planned and actual outcomes. It is therefore appropriate to leave some margin for correction of inaccuracies in the virtual planning. In this sense, it may be appropriate to use only the intermediate splint, and then use the planned occlusion and clinical measurements to guide repositioning of the second jaw and chin, respectively. (c) 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:293 / 298
页数:6
相关论文
共 24 条
[1]   3D planning in orthognathic surgery: CAD/CAM surgical splints and prediction of the soft and hard tissues results - Our experience in 16 cases [J].
Aboul-Hosn Centenero, Samir ;
Hernandez-Alfaro, Federico .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2012, 40 (02) :162-168
[2]  
BAILEY JO, 1981, J DENT RES, V60, P531
[3]   A comparative study of two arbitrary face-bow transfer systems for orthognathic surgery planning [J].
Bamber, MA ;
Firouzai, R ;
Harris, M ;
Linney, A .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 25 (05) :339-343
[4]   POSTERIOR BORDER MOVEMENTS OF HUMAN MANDIBLE [J].
BOUCHER, L ;
JACOBY, J .
JOURNAL OF PROSTHETIC DENTISTRY, 1961, 11 (05) :836-&
[5]   RELIABILITY OF A FACEBOW TRANSFER PROCEDURE [J].
BOWLEY, JF ;
MICHAELS, GC ;
LAI, TW ;
LIN, PP .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 67 (04) :491-498
[6]   Computer-assisted orthognathic surgery for correction of facial asymmetry: results of a randomised controlled clinical trial [J].
De Riu, Giacomo ;
Meloni, Silvio Mario ;
Baj, Alessandro ;
Corda, Andrea ;
Soma, Damiano ;
Tullio, Antonio .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2014, 52 (03) :251-257
[7]   ACCURACY OF FACE-BOW TRANSFER - EFFECT ON SURGICAL PREDICTION AND POSTSURGICAL RESULT [J].
ELLIS, E ;
THARANON, W ;
GAMBRELL, K .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1992, 50 (06) :562-567
[8]   Complications after orthognathic surgery: our experience on 423 cases [J].
Friscia M. ;
Sbordone C. ;
Petrocelli M. ;
Vaira L.A. ;
Attanasi F. ;
Cassandro F.M. ;
Paternoster M. ;
Iaconetta G. ;
Califano L. .
Oral and Maxillofacial Surgery, 2017, 21 (2) :171-177
[9]   A comparison of 3 methods of face-bow transfer recording: Implications for orthognathic surgery [J].
Gateno, J ;
Forrest, KK ;
Camp, B .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2001, 59 (06) :635-640
[10]   VARIATION OF RETRUDED AND MUSCULAR POSITION OF MANDIBLE UNDER DIFFERENT RECORDING CONDITIONS [J].
HELKIMO, M ;
INGERVALL, B ;
CARLSSON, GE .
ACTA ODONTOLOGICA SCANDINAVICA, 1971, 29 (04) :423-+