An optimized method to assess in vivo efficacy of antithrombotic drugs using optical coherence tomography and a modified Doppler flow system

被引:10
作者
Couture, L. [1 ]
Richer, L. P. [1 ]
Cadieux, C. [1 ]
Thomson, C. M. [1 ]
Hossain, S. M. [1 ]
机构
[1] Natl Res Council Canada, Biotechnol Res Inst, Vivo Pharmacol Dept, Montreal, PQ H4P 2R2, Canada
关键词
Blood flow; Ferric chloride; Methods; Optical coherence tomography; Time to occlusion; Thrombus; ARTERIAL THROMBOSIS; RAT MODEL;
D O I
10.1016/j.vascn.2011.09.001
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Introduction: Animal models of venous and arterial thrombosis are extremely useful to study the efficacy of antithrombotic agents. Variability in efficacy data is often observed in those preclinical studies. The goal of this study was to optimize the methodology for assessing antithrombotic drug efficacy by the use of optical coherence tomography (OCT) and a modified Doppler flow system in rat models of thrombosis. Methods: Thrombus formation was assessed in both the rat venous and arterial ferric chloride (FeCl3) models of thrombosis. In the venous model, thrombus volume post-treatment was measured using OCT, and data were correlated against the thrombus weight. In the arterial model, the time to occlusion was measured using a Doppler flow probe connected to a perivascular flow module which allowed the reporting of dynamic blood flow data every 30 s. Heparin (130 or 165 U/kg), argatroban (4.5 mg/kg), bivalirudin (1.3 mg/kg) or saline were administered intravenously. Results: In the venous model, for all treatment groups a strong linear correlation (R-2 = 0.998) was observed between thrombus volume measured by OCT and thrombus weight. In the arterial model, using a high sampling rate of a dynamic blood flow using a modified Doppler flow system provided data accuracy and precision of the time to occlusion measurement. Discussion: This study demonstrates that OCT is a powerful tool for the assessment of antithrombotic drug efficacy. Furthermore, it shows that a high Doppler sampling rates of dynamic blood flow leads to data accuracy and precision. Crown Copyright (C) 2011 Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:264 / 268
页数:5
相关论文
共 24 条
  • [1] Abramoff M.D., 2004, Biophotonics International, V11, P36
  • [2] Mechanisms underlying FeCl3-induced arterial thrombosis
    Eckly, A.
    Hechler, B.
    Freund, M.
    Zerr, M.
    Cazenave, J. -P.
    Lanza, F.
    Mangin, P. H.
    Gachet, C.
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 (04) : 779 - 789
  • [3] Practical issues in the development of argatroban: A perspective
    Fareed, J
    Hoppensteadt, D
    Iqbal, O
    Tobu, M
    Lewis, BE
    [J]. PATHOPHYSIOLOGY OF HAEMOSTASIS AND THROMBOSIS, 2002, 32 : 56 - 65
  • [4] Cancer-associated thrombosis
    Furie, B
    Furie, BC
    [J]. BLOOD CELLS MOLECULES AND DISEASES, 2006, 36 (02) : 177 - 181
  • [5] Thrombus formation in vivo
    Furie, B
    Furie, BC
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 2005, 115 (12) : 3355 - 3362
  • [6] Effect of tiplaxtinin (PAI-039), an orally bioavailable PAI-1 antagonist, in a rat model of thrombosis
    Hennan, J. K.
    Morgan, G. A.
    Swillo, R. E.
    Antrilli, T. M.
    Mugford, C.
    Vlasuk, G. P.
    Gardell, S. J.
    Crandall, D. L.
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2008, 6 (09) : 1558 - 1564
  • [7] KLEINBAUM DG, 2008, APPL REGRESSION ANAL, pCH4
  • [8] Fibrin clot visualized by optical coherence tomography
    Kume, Teruyoshi
    Okura, Hiroyuki
    Kawamoto, Takahiro
    Akasaka, Takashi
    Toyota, Eiji
    Watanabe, Nozomi
    Neishi, Yoji
    Sadahira, Yoshito
    Yoshida, Kiyoshi
    [J]. CIRCULATION, 2008, 118 (04) : 426 - 427
  • [9] Assessment of coronary arterial thrombus by optical coherence tomography
    Kume, Teruyoshi
    Akasaka, Takashi
    Kawamoto, Takahiro
    Ogasawara, Yasuo
    Watanabe, Nozorni
    Toyota, Eiji
    Neishi, Yoji
    Sukmawan, Renan
    Sadahira, Yoshito
    Yoshida, Kiyoshi
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (12) : 1713 - 1717
  • [10] Measurement of the thickness of the fibrous cap by optical coherence tomography
    Kume, Teruyoshi
    Akasaka, Takashi
    Kawamoto, Takahiro
    Okura, Hiroyuki
    Watanabe, Nozomi
    Toyota, Eiji
    Neishi, Yoji
    Sukmawan, Renan
    Sadahira, Yoshito
    Yoshida, Kiyoshi
    [J]. AMERICAN HEART JOURNAL, 2006, 152 (04) : 755.e1 - 755.e4