Performances' investigation of different photovoltaic water pumping system configurations for proper matching the optimal location, in desert area

被引:11
作者
Boutelhig, Azzedine [1 ,2 ]
Hanini, Salah [2 ]
Arab, Amar Hadj [3 ]
机构
[1] CDER, URAER, Ghardaia 47133, Algeria
[2] Univ Yahia Fares, Lab LBPT Energie Renouvelable, Medea, Algeria
[3] CDER, BP 62 Route Observ, Algiers 16340, Algeria
关键词
Feasibility study; Reliable; Geospatial distribution; Optimally matched; Suitable location; EXPERIMENTAL VALIDATION; IRRIGATION SYSTEM; POWER; OPTIMIZATION; FEASIBILITY; ALGERIA; ENERGY; MODEL;
D O I
10.1016/j.enconman.2017.09.012
中图分类号
O414.1 [热力学];
学科分类号
摘要
The standard sizing methodology of photovoltaic water pumping system is limited only on how to determine at least the number and type of solar panels required for capturing the needed solar energy, by considering the daily water flow and the total dynamic head. However, the feedbacks following different on-site operating tests proved that the lack of information on the geospatial of the area led to unexpected dysfunctions and failure in the system optimality. Accordingly, any deficiency in the comprehensive feasibility study, regarding the specifics of the soil, the climate, groundwater behavior, water demand/supply balance, technique of irrigation and kind of activity, can be the main hindrance to obtain a reliable system. Through this attempt, the field performance suitability of four different photovoltaic water pumping system configurations, namely; (DC/PVPS1), (DC/PVPS2), (DC/PVPS3) and (DC/PVPS4) have been investigated and discussed, according to the Ghardaia land specifics. Based on the characterization data, obtained following the test carried out on the mentioned configurations, at our PV water pumping test facility, the system performances have been assessed, at different pumping head levels ranging from 10 m until 30 m. In the meanwhile, the hydraulic characteristics have been calculated and the corresponding required peak powers have been estimated, for different dust and thermal losses. Thus, upon the geospatial characteristic distribution of the Ghardaia territory, each system configuration has been optimally matched to the suitable location. The adopted methodology can be an efficient tool to select technically and economically the appropriate system to the suitable area.
引用
收藏
页码:439 / 456
页数:18
相关论文
共 46 条
[1]   Improving the effectiveness of a photovoltaic water pumping system by spraying water over the front of photovoltaic cells [J].
Abdolzadeh, M. ;
Ameri, M. .
RENEWABLE ENERGY, 2009, 34 (01) :91-96
[2]  
Algerian Ministry of Energy and mines, 2011, REN EN PROGR EN EFF
[3]   Non linear control of a photovoltaic water pumping System [J].
Andoulssi, R. ;
Draou, A. ;
Jerbi, H. ;
Alghonamy, A. ;
Khiari, B. .
MEDITERRANEAN GREEN ENERGY FORUM 2013: PROCEEDINGS OF AN INTERNATIONAL CONFERENCE MGEF-13, 2013, 42 :328-336
[4]  
[Anonymous], 2009, GROUND WAT IN PRESS
[5]  
[Anonymous], 2004, RENEWABLE EFFICIENT
[6]   Loss-of-load probability of photovoltaic water pumping systems [J].
Arab, AH ;
Chenlo, F ;
Benghanem, M .
SOLAR ENERGY, 2004, 76 (06) :713-723
[7]   Optimal sizing of photovoltaic pumping system with water tank storage using LPSP concept [J].
Bakelli, Yahia ;
Arab, Amar Hadj ;
Azoui, Boubekeur .
SOLAR ENERGY, 2011, 85 (02) :288-294
[8]   A real-time control of photovoltaic water-pumping network [J].
Ben Salah, Chokri ;
Mimouni, Mohamed Faouzi ;
Ouali, Mohamed .
COMPUTERS & ELECTRICAL ENGINEERING, 2015, 46 :14-28
[9]   Performances study of different PV powered DC pump configurations for an optimum energy rating at different heads under the outdoor conditions of a desert area [J].
Boutelhig, A. ;
Bakelli, Y. ;
Mahammed, I. Hadj ;
Arab, A. Hadj .
ENERGY, 2012, 39 (01) :33-39
[10]   Comparison Study to Select an Optimum Photovoltaic Pumping System (PVPS) Configuration upon Experimental Performances Data of Two Different DC Pumps Tested at Gharda a Site [J].
Boutelhig, A. ;
Hadjarab, A. ;
Bakelli, Y. .
IMPACT OF INTEGRATED CLEAN ENERGY ON THE FUTURE OF THE MEDITERRANEAN ENVIRONMENT, 2011, 6 :769-776