Landmark-driven Parameter Optimization for non-linear Image Registration

被引:4
作者
Schmidt-Richberg, Alexander [1 ]
Werner, Rene [1 ]
Ehrhardt, Jan [1 ]
Wolf, Jan-Christoph [1 ]
Handels, Heinz [1 ]
机构
[1] Univ Lubeck, Inst Med Informat, Lubeck, Germany
来源
MEDICAL IMAGING 2011: IMAGE PROCESSING | 2011年 / 7962卷
关键词
registration; landmark detection; parameter optimization;
D O I
10.1117/12.877059
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Image registration is one of the most common research areas in medical image processing. It is required for example for image fusion, motion estimation, patient positioning, or generation of medical atlases. In most intensity-based registration approaches, parameters have to be determined, most commonly a parameter indicating to which extend the transformation is required to be smooth. Its optimal value depends on multiple factors like the application and the occurrence of noise in the images, and may therefore vary from case to case. Moreover, multi-scale approaches are commonly applied on registration problems and demand for further adjustment of the parameters. In this paper, we present a landmark-based approach for automatic parameter optimization in non-linear intensity-based image registration. In a first step, corresponding landmarks are automatically detected in the images to match. The landmark-based target registration error (TRE), which is shown to be a valid metric for quantifying registration accuracy, is then used to optimize the parameter choice during the registration process. The approach is evaluated for the registration of lungs based on 22 thoracic 4D CT data sets. Experiments show that the TRE can be reduced on average by 0.07 mm using automatic parameter optimization.
引用
收藏
页数:8
相关论文
共 13 条
  • [1] A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets
    Castillo, Richard
    Castillo, Edward
    Guerra, Rudy
    Johnson, Valen E.
    McPhail, Travis
    Garg, Amit K.
    Guerrero, Thomas
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (07) : 1849 - 1870
  • [2] Ehrhardt J., 2010, MEDICAL IMAGE ANAL C, P165
  • [3] Ehrhardt J., 2009, 2 INT WORKSH PULM IM, P3
  • [4] An optical flow based method for improved reconstruction of 4D CT data sets acquired during free breathing
    Ehrhardt, Jan
    Werner, Rene
    Saering, Dennis
    Frenzel, Thorsten
    Lu, Wei
    Low, Daniel
    Handels, Heinz
    [J]. MEDICAL PHYSICS, 2007, 34 (02) : 711 - 721
  • [5] Evaluation of 3D operators for the detection of anatomical point landmarks in MR and CT images
    Hartkens, T
    Rohr, K
    Stiehl, HS
    [J]. COMPUTER VISION AND IMAGE UNDERSTANDING, 2002, 86 (02) : 118 - 136
  • [6] Modersitzki J., 2003, NUMER MATH SCI COMP, DOI 10.1093/acprof:oso/9780198528418.001.0001
  • [7] More J. J., 1978, LECT NOTES MATH, V630, P105
  • [8] Murphy K., 2008, INT C MED IM COMP 2, V11, P1006
  • [9] Olesch J., 2009, IMAGE PROCESSING SPI, V7261
  • [10] Landmark-based elastic registration using approximating thin-plate splines
    Rohr, K
    Stiehl, HS
    Sprengel, R
    Buzug, TM
    Weese, J
    Kuhn, MH
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (06) : 526 - 534