Solar grid-connected three-phase system with active and reactive power control and input voltage clamped

被引:2
|
作者
Schonardie, Mateus F. [1 ]
Martins, Denizar C. [1 ]
机构
[1] Univ Fed Santa Catarina, INEP, Power Elect Inst, Florianopolis, SC, Brazil
来源
2007 14TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, VOLS 1-4 | 2007年
关键词
D O I
10.1109/ICECS.2007.4511030
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a model of the three-phase PWM inverter and a control strategy using dq0 transformation to be employed in a grid connected photovoltaic generation system. The proposed system operates as an active filter capable of compensate harmonic components and reactive power, generated by the other loads connected to the system. To control the power between the grid and photovoltaic system it is proposed the input voltage clamping of the inverter technique, where it is intended to achieve the maximum power point operation. Following, simulation results and analyses are presented to validate the proposed methodology for grid connected photovoltaic generation system.
引用
收藏
页码:463 / 466
页数:4
相关论文
共 50 条
  • [31] Active and Reactive Power Control Techniques Based on Feedback Linearization and Fuzzy Logic for Three-Phase Grid-Connected Photovoltaic Inverters
    Nguyen Gia Minh Thao
    Uchida, Kenko
    ASIAN JOURNAL OF CONTROL, 2015, 17 (05) : 1522 - 1546
  • [32] Outer loop voltage control method based on dc power control of three-phase grid-connected inverter
    Du, Jifei
    Zhao, Hongyan
    Trillion, Q. Zheng
    Sun, Hu
    Li, Danyong
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2019, 40 (09): : 2622 - 2629
  • [33] Voltage Sensorless Improved Model Predictive Direct Power Control for Three-Phase Grid-Connected Converters
    Bozorgi, Amir Masoud
    Gholami-Khesht, Hosein
    Farasat, Mehdi
    Mehraeen, Shahab
    Monfared, Mohammad
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 4957 - 4963
  • [34] The influence of grid-connected three-phase inverters on voltage unbalance
    Meersman, Bart
    Renders, Bert
    Degroote, Lieven
    Vandoorn, Tine
    Vandevelde, Lieven
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [35] Active disturbance rejection control of three-phase grid-connected photovoltaic systems
    Li, Hezheng
    Bai, Jing
    Kanae, Shunshoku
    Li, Yanxi
    Yue, Lin
    INTERNATIONAL JOURNAL OF MODELLING IDENTIFICATION AND CONTROL, 2019, 33 (03) : 225 - 236
  • [36] A simple direct power control of a three-phase inverter for a grid-connected wind energy system
    Zogogianni, Charoula G.
    Tatakis, Emmanuel C.
    2014 16TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'14-ECCE EUROPE), 2014,
  • [37] Active power control of three-phase grid-connected solar PV systems using a robust nonlinear adaptive backstepping approach
    Roy, T. K.
    Mahmud, M. A.
    SOLAR ENERGY, 2017, 153 : 64 - 76
  • [38] Power oscillation analysis and control of three-phase grid-connected voltage source converters under unbalanced grid faults
    Du, Xiong
    Wu, Yue
    Gu, Shida
    Tai, Heng-Ming
    Sun, Pengju
    Ji, Yongliang
    IET POWER ELECTRONICS, 2016, 9 (11) : 2162 - 2173
  • [39] A three-phase grid-connected inverter equipped with a shunt instantaneous reactive power compensator
    Takagi K.
    Fujita H.
    IEEJ Transactions on Industry Applications, 2018, 138 (06) : 530 - 537
  • [40] A Three-Phase Grid-Connected Inverter Equipped With a Shunt Instantaneous Reactive Power Compensator
    Takagi, Kazuto
    Fujita, Hideaki
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 589 - 596