In vivo assessment of magnesium status in human body using accelerator-based neutron activation measurement of hands:: A pilot study

被引:20
作者
Aslam [1 ]
Pejovic-Milic, A. [1 ,2 ]
McNeill, F. E. [1 ]
Byun, S. H. [1 ]
Prestwich, W. V. [1 ]
Chettle, D. R. [1 ]
机构
[1] McMaster Univ, Dept Med Phys & Appl Radiat Sci, Hamilton, ON L8S 4K1, Canada
[2] Ryerson Univ, Dept Phys, Toronto, ON M5B 2K3, Canada
关键词
magnesium assessment; clinical diagnostic test; bone; noninvasive; in vivo; neutron activation; humans; body composition; accelerator; BONE ALUMINUM; TRACE-ELEMENTS; MANGANESE; DESIGN; CAVITY; SYSTEM;
D O I
10.1118/1.2830383
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnesium (Mg) is an element essential for many enzymatic reactions in the human body. Various human and animal studies suggest that changes in Mg status are linked to diseases such as cardiac arrhythmia, coronary heart disease, hypertension, premenstrual syndrome, and diabetes mellitus. Thus, knowledge of Mg levels in the human body is needed. A direct measurement of human blood serum, which contains only 0.3% of the total body Mg, is generally used to infer information about the status of Mg in the body. However, in many clinical situations, Mg stored in large levels, for example in bones, muscles, and soft tissues, needs to be monitored either to evaluate the efficacy of a treatment or to study the progression of diseases associated with the deficiency of total body Mg. This work presents a feasibility study of a noninvasive, in vivo neutron activation analysis (IVNAA) technique using the Mg-26(n, gamma) Mg-27 reaction to measure Mg levels in human hands. The technique employs the McMaster University high beam current Tandetron accelerator hand irradiation facility and an array of eight NaI (T1) detectors arranged in a 4 pi geometry for delayed counting of the 0.844 and 1.014 MeV gamma rays emitted when Mg-27 decays in the irradiated hand. Mg determination in humans using IVNAA of hands has been demonstrated to be feasible, with effective doses as low as one-quarter of those delivered in chest x rays. The overall experimental uncertainty in the measurements is estimated to be approximately 5% (1 sigma). The results are found to be in the range of the in vitro measurements reported for other cortical bones collected from different sites of the human skeleton, which confirms that this technique mainly provides a measure of the amount of Mg in hand bones. The average concentration of Mg determined in human hands is 10.96 +/- 1.25 (+/-1 SD) mg Mg/g Ca. The coefficient of variation (11%) observed in this study is comparable with or lower than several studies using in vitro measurements reported in the literature and therefore allows for a quantitative intersubject comparison, even if to a limited extent. The features of the developed technique such as its simplicity, rapidity, accuracy, robustness, noninvasive nature, and very effective use of radiation doses, present the technique as a viable diagnostic tool available for trial in a clinical environment. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:608 / 616
页数:9
相关论文
共 45 条
  • [31] Development of an irradiation/shielding cavity for in vivo neutron activation analysis of manganese in human bone
    Pejovic-Milic, A.
    Byun, S. H.
    Chettle, D. R.
    McNeill, F. E.
    Prestwich, W. V.
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2006, 269 (02) : 417 - 420
  • [32] In vivo measurement of bone aluminium: Recent developments
    Pejovic-Milic, A
    Byun, SH
    Comsa, DC
    McNeill, FE
    Prestwich, WV
    Chettle, DR
    [J]. JOURNAL OF INORGANIC BIOCHEMISTRY, 2005, 99 (09) : 1899 - 1903
  • [33] Development of an accelerator based determination of aluminum burden in peripheral bone by neutron activation analysis
    Pejovic-Milic, A
    McNeill, FE
    Prestwich, WV
    Waker, AJ
    Chettle, DR
    [J]. APPLIED RADIATION AND ISOTOPES, 1998, 49 (5-6) : 717 - 719
  • [34] Monte Carlo design study for in vivo bone aluminum measurement using a low energy accelerator beam
    Pejovic-Milic, A
    Arnold, ML
    McNeill, FE
    Chettle, DR
    [J]. APPLIED RADIATION AND ISOTOPES, 2000, 53 (4-5) : 657 - 664
  • [35] PEJOVICMILIC A, 1998, THESIS MCMASTER U HA
  • [36] PEJOVICMILIC A, 2001, THESIS MCMASTER U HA
  • [37] Magnesium deficiency and osteoporosis: animal and human observations
    Rude, RK
    Gruber, HE
    [J]. JOURNAL OF NUTRITIONAL BIOCHEMISTRY, 2004, 15 (12) : 710 - 716
  • [38] DETERMINATION OF MAJOR AND TRACE-ELEMENTS IN BONES BY SIMULTANEOUS PIXE PIGE ANALYSIS
    SAMUDRALWAR, DL
    ROBERTSON, JD
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1993, 169 (01): : 259 - 267
  • [39] A review of in vivo experimental methods to determine the composition of the human body
    Sutcliffe, JF
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (05) : 791 - 833
  • [40] Trace element determinations in human cortical and trabecular bones
    Takata, MK
    Saiki, M
    Sumita, NM
    Saldiva, PHN
    Pasqualucci, CA
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 264 (01) : 5 - 8