In vivo assessment of magnesium status in human body using accelerator-based neutron activation measurement of hands:: A pilot study

被引:20
作者
Aslam [1 ]
Pejovic-Milic, A. [1 ,2 ]
McNeill, F. E. [1 ]
Byun, S. H. [1 ]
Prestwich, W. V. [1 ]
Chettle, D. R. [1 ]
机构
[1] McMaster Univ, Dept Med Phys & Appl Radiat Sci, Hamilton, ON L8S 4K1, Canada
[2] Ryerson Univ, Dept Phys, Toronto, ON M5B 2K3, Canada
关键词
magnesium assessment; clinical diagnostic test; bone; noninvasive; in vivo; neutron activation; humans; body composition; accelerator; BONE ALUMINUM; TRACE-ELEMENTS; MANGANESE; DESIGN; CAVITY; SYSTEM;
D O I
10.1118/1.2830383
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnesium (Mg) is an element essential for many enzymatic reactions in the human body. Various human and animal studies suggest that changes in Mg status are linked to diseases such as cardiac arrhythmia, coronary heart disease, hypertension, premenstrual syndrome, and diabetes mellitus. Thus, knowledge of Mg levels in the human body is needed. A direct measurement of human blood serum, which contains only 0.3% of the total body Mg, is generally used to infer information about the status of Mg in the body. However, in many clinical situations, Mg stored in large levels, for example in bones, muscles, and soft tissues, needs to be monitored either to evaluate the efficacy of a treatment or to study the progression of diseases associated with the deficiency of total body Mg. This work presents a feasibility study of a noninvasive, in vivo neutron activation analysis (IVNAA) technique using the Mg-26(n, gamma) Mg-27 reaction to measure Mg levels in human hands. The technique employs the McMaster University high beam current Tandetron accelerator hand irradiation facility and an array of eight NaI (T1) detectors arranged in a 4 pi geometry for delayed counting of the 0.844 and 1.014 MeV gamma rays emitted when Mg-27 decays in the irradiated hand. Mg determination in humans using IVNAA of hands has been demonstrated to be feasible, with effective doses as low as one-quarter of those delivered in chest x rays. The overall experimental uncertainty in the measurements is estimated to be approximately 5% (1 sigma). The results are found to be in the range of the in vitro measurements reported for other cortical bones collected from different sites of the human skeleton, which confirms that this technique mainly provides a measure of the amount of Mg in hand bones. The average concentration of Mg determined in human hands is 10.96 +/- 1.25 (+/-1 SD) mg Mg/g Ca. The coefficient of variation (11%) observed in this study is comparable with or lower than several studies using in vitro measurements reported in the literature and therefore allows for a quantitative intersubject comparison, even if to a limited extent. The features of the developed technique such as its simplicity, rapidity, accuracy, robustness, noninvasive nature, and very effective use of radiation doses, present the technique as a viable diagnostic tool available for trial in a clinical environment. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:608 / 616
页数:9
相关论文
共 45 条
  • [1] ANDERSON J, 1964, LANCET 2, V201, P1205
  • [2] Trace elements in human bone determined by neutron activation analysis
    Aras, NK
    Yilmaz, G
    Alkan, S
    Korkusuz, F
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1999, 239 (01) : 79 - 86
  • [3] Arnold ML, 1999, NEUROTOXICOLOGY, V20, P407
  • [4] An accelerator based system for in vivo neutron activation analysis measurements of manganese in human hand bones
    Arnold, ML
    McNeill, FE
    Stronach, IM
    Pejovic-Milic, A
    Chettle, DR
    Waker, A
    [J]. MEDICAL PHYSICS, 2002, 29 (11) : 2718 - 2724
  • [5] System design for in vivo neutron activation analysis measurements of manganese in the human brain: based on Monte Carlo modeling
    Arnold, ML
    McNeill, FE
    Prestwich, WV
    Chettle, DR
    [J]. APPLIED RADIATION AND ISOTOPES, 2000, 53 (4-5) : 651 - 656
  • [6] ARNOLD ML, 2000, THESIS MCMASTER U HA
  • [7] Monte Carlo simulation of neutron irradiation facility developed for accelerator based in vivo neutron activation measurements in human hand bones
    Aslam
    Prestwich, WV
    McNeill, FE
    Waker, AJ
    [J]. APPLIED RADIATION AND ISOTOPES, 2006, 64 (01) : 63 - 84
  • [8] Development of a low-energy monoenergetic neutron source for applications in low-dose radiobiological and radiochemical research
    Aslam
    Prestwich, WV
    McNeill, FE
    Waker, AJ
    [J]. APPLIED RADIATION AND ISOTOPES, 2003, 58 (06) : 629 - 642
  • [9] Investigating the TEPC radiation quality factor response for low energy accelerator based clinical applications
    Aslam
    Prestwich, WV
    McNeill, FE
    Waker, AJ
    [J]. RADIATION PROTECTION DOSIMETRY, 2003, 103 (04) : 311 - 322
  • [10] Lithium target performance evaluation for low-energy accelerator-based in vivo measurements using gamma spectroscopy
    Aslam
    Prestwich, WV
    McNeill, FE
    [J]. APPLIED RADIATION AND ISOTOPES, 2003, 58 (03) : 321 - 331