Test-retest reliability of a portable monitor to assess energy expenditure

被引:0
作者
Brazeau, Anne-Sophie [1 ,2 ,3 ]
Karelis, Antony D. [2 ,4 ]
Mignault, Diane [2 ,5 ]
Lacroix, Marie-Josee [2 ]
Prud'homme, Denis [6 ]
Rabasa-Lhoret, Remi [1 ,2 ,3 ]
机构
[1] Montreal Clin Res Inst IRCM, Montreal, PQ, Canada
[2] Univ Montreal, Dept Nutr, Montreal, PQ H3T 1A8, Canada
[3] Univ Montreal Hosp Res Ctr CR CHUM, Montreal Diabet Res Ctr MDRC, Montreal, PQ H1W 4A4, Canada
[4] Univ Quebec, Dept Kinanthropol, Montreal, PQ H2X 3R9, Canada
[5] Montreal Clin Res Inst IRCM, Montreal, PQ H2W 1R7, Canada
[6] Univ Ottawa, Fac Hlth Sci, Sch Human Kinet, Ottawa, ON K1N 6N5, Canada
来源
APPLIED PHYSIOLOGY NUTRITION AND METABOLISM-PHYSIOLOGIE APPLIQUEE NUTRITION ET METABOLISME | 2011年 / 36卷 / 03期
基金
加拿大健康研究院;
关键词
test-retest; activity monitoring; motion sensors; energy expenditure; accelerometer; physical activity; OBSTRUCTIVE PULMONARY-DISEASE; PHYSICAL-ACTIVITY; MULTISENSOR ARMBAND; WEIGHT-LOSS; EXERCISE; ADULTS; TECHNOLOGY; ACCURACY; SYSTEM; DEVICE;
D O I
10.1139/H11-016
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
The ability of the SenseWear Armband (SWA) to estimate energy expenditure (EE) in adults is established. However, except for resting metabolic rate, the test-retest reliability of the SWA for the estimation of EE in adults is unknown. To explore reliability, 34 healthy adults (50% women; age, 26.7 +/- 6.1 years; body mass index, 23.6 +/- 3.3 kg(.)m(-2)) completed a 2-day study protocol. During 13 h of direct supervision, subjects completed, each day, 60 min of lying awake rest, 30 min of structured sedentary activity, 45 min of walking circuit, and 45 min of ergocycling at 50% of their peak oxygen uptake. For the remaining 10 h, subjects remained seated. The SWA showed significant intraclass correlations between the 2 days of testing for the overall 13 h of direct supervision (r = 0.97; p < 0.001), the lying awake rest (r = 0.98; p < 0.001), the structured sedentary activity (r = 0.62; p < 0.05), the walking circuit (r = 0.95; p < 0.001), and the standardized physical activity (r = 0.85; p < 0.001). The results of this study indicate that the SWA is a reliable tool to estimate EE during multiple activities. These data provide additional evidence of the usefulness of the SWA in monitoring EE in healthy adults.
引用
收藏
页码:339 / 343
页数:5
相关论文
共 50 条
  • [1] Test-Retest Reliability of the 20-sec Wingate Test to Assess Anaerobic Power in Children with Cerebral Palsy
    Dallmeijer, Annet J.
    Scholtes, Vanessa A. B.
    Brehm, Merel-Anne
    Becher, Jules G.
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2013, 92 (09) : 762 - 767
  • [2] Test-Retest Reliability of Portable Metabolic Monitoring After Disabling Stroke
    Stookey, Alyssa D.
    McCusker, Michael G.
    Sorkin, John D.
    Katzel, Leslie I.
    Shaughnessy, Marianne
    Macko, Richard F.
    Ivey, Frederick M.
    NEUROREHABILITATION AND NEURAL REPAIR, 2013, 27 (09) : 872 - 877
  • [3] Test-Retest Reliability of the Twin Cities Walking Survey
    Forsyth, Ann
    Oakes, J. Michael
    Schmitz, Kathryn H.
    JOURNAL OF PHYSICAL ACTIVITY & HEALTH, 2009, 6 (01) : 119 - 131
  • [4] The test-retest reliability and criterion validity of the Sensewear mini and Actiheart in two climatologically different countries
    Baldew, Se-Sergio M.
    Avila, Andrea
    Claes, Jomme
    Toelsie, Jerry R.
    Luc Vanhees
    Cornelissen, Veronique
    HEALTH AND TECHNOLOGY, 2019, 9 (04) : 647 - 656
  • [5] Test-retest reliability of the Military Pre-training Questionnaire
    Robinson, M.
    Stokes, K.
    Bilzon, J.
    Standage, M.
    Brown, P.
    Thompson, D.
    OCCUPATIONAL MEDICINE-OXFORD, 2010, 60 (06): : 476 - 483
  • [6] Test-Retest Reliability of the Step Watch Activity Monitor Outputs in Healthy Adults
    Mudge, Suzie
    Taylor, Denise
    Chang, Oliver
    Wong, Rosita
    JOURNAL OF PHYSICAL ACTIVITY & HEALTH, 2010, 7 (05) : 671 - 676
  • [7] Workplace Sitting Breaks Questionnaire (SITBRQ): an assessment of concurrent validity and test-retest reliability
    Pedisic, Zeljko
    Bennie, Jason A.
    Timperio, Anna F.
    Crawford, David A.
    Dunstan, David W.
    Bauman, Adrian E.
    Salmon, Jo
    BMC PUBLIC HEALTH, 2014, 14
  • [8] The Test-Retest Reliability of 10 Meters Maximal Walking Speed in Older People Living in a Residential Care Unit
    Adell, Eva
    Wehmhorner, Silke
    Rydwik, Elisabeth
    JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2013, 36 (02) : 74 - 77
  • [9] An evaluation of the IDEEA™ activity monitor for estimating energy expenditure
    Whybrow, Stephen
    Ritz, Patrick
    Horgan, Graham W.
    Stubbs, R. James
    BRITISH JOURNAL OF NUTRITION, 2013, 109 (01) : 173 - 183
  • [10] Test-retest reliability and convergent validity of attention measures
    Fernandez-Marcos, Tatiana
    de la Fuente, Cristina
    Santacreu, Jose
    APPLIED NEUROPSYCHOLOGY-ADULT, 2018, 25 (05) : 464 - 472