Changes in corneal Langerhans cell density during the first few hours of contact lens wear

被引:37
作者
Alzahrani, Yahya
Pritchard, Nicola
Efron, Nathan [1 ]
机构
[1] Queensland Univ Technol, Inst Hlth & Biomed Innovat, Kelvin Grove, Australia
关键词
Contact lens; Cornea; Langerhans cells; Laser scanning confocal microscopy; ANTIGEN-PRESENTING CELLS; VIVO CONFOCAL MICROSCOPY; DENDRITIC CELLS; EPITHELIUM; POPULATION; KERATITIS; EYE;
D O I
10.1016/j.clae.2016.02.008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the impact of contact lens wear on Langerhans cell density (LCD) in the central cornea over an 8 h period. Methods: Ten participants wore a hydrogel lens in one eye (the experimental eye) for 8 h. The contralateral non-lens-wearing eye served as a control. The central cornea of each eye was examined at the level of the subbasal nerve plexus using a laser scanning corneal confocal microscope, at baseline (prior to lens wear), then every 2 h for 8 h. Results: At baseline, LCD was 18 +/- 19 and 20 +/- 19 cells/mm(2) in the experimental and control eyes, respectively. In the experimental eye, LCD increased to 36 +/- 32 cells/mm2 after 2 h and then decreased gradually to 30 +/- 31 cells/mm(2) after 6 h. LCD was greater in the experimental eye than the control eye at the 2, 4, 6 and 8 h time points (p < 0.05). LCD remained constant in the control eye throughout the 8 h experiment. Conclusions: LCD increases two-fold within the first 2 h of lens wear, indicating a rapid, sub-clinical inflammatory response to uncomplicated lens wear. (C) 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:307 / 310
页数:4
相关论文
共 21 条
[1]   THE RESPONSE OF LANGERHANS CELLS IN THE CORNEA TO HERPETIC-KERATITIS [J].
ASBELL, PA ;
KAMENAR, T .
CURRENT EYE RESEARCH, 1987, 6 (01) :179-182
[2]   Existence of small slow-cycling Langerhans cells in the limbal basal epithelium that express ABCG2 [J].
Chen, Wensheng ;
Hara, Koji ;
Tian, Qing ;
Zhao, Kanxing ;
Yoshitomi, Takeshi .
EXPERIMENTAL EYE RESEARCH, 2007, 84 (04) :626-634
[3]   Hypoxic effects on the anterior eye of high-Dk soft contact lens wearers are negligible [J].
Covey, M ;
Sweeney, DF ;
Terry, R ;
Sankaridurg, PR ;
Holden, BA .
OPTOMETRY AND VISION SCIENCE, 2001, 78 (02) :95-99
[4]  
EFRON N, 1986, AM J OPTOM PHYS OPT, V63, P819
[5]   Confocal Microscopy of the Bulbar Conjunctiva in Contact Lens Wear [J].
Efron, Nathan ;
Al-Dossari, Munira ;
Pritchard, Nicola .
CORNEA, 2010, 29 (01) :43-52
[6]  
GILLETTE TE, 1982, OPHTHALMOLOGY, V89, P700
[7]   Corneal immunity is mediated by heterogeneous population of antigen-presenting cells [J].
Hamrah, P ;
Huq, SO ;
Liu, Y ;
Zhang, Q ;
Dana, MR .
JOURNAL OF LEUKOCYTE BIOLOGY, 2003, 74 (02) :172-178
[8]  
Hamrah P, 2002, INVEST OPHTH VIS SCI, V43, P639
[9]   Characterization of antigen-presenting cells in fresh and cultured human corneas using novel dendritic cell markers [J].
Mayer, Wolfgang J. ;
Irschick, Ulrike M. ;
Moser, Patrizia ;
Wurm, Martin ;
Huemer, Hartwig P. ;
Romani, Nikolaus ;
Irschick, Eveline U. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (10) :4459-4467
[10]   Distribution of Antigen Presenting Cells in the Human Cornea: Correlation of In Vivo Confocal Microscopy and Immunohistochemistry in Different Pathologic Entities [J].
Mayer, Wolfgang J. ;
Mackert, Marc J. ;
Kranebitter, Nicole ;
Messmer, Elisabeth M. ;
Grueterich, Martin ;
Kampik, Anselm ;
Kook, Daniel .
CURRENT EYE RESEARCH, 2012, 37 (11) :1012-1018