Condensation heat transfer for R-22 and R-407C refrigerant-oil mixtures in a microfin tube with a U-bend

被引:56
|
作者
Cho, K [1 ]
Tae, SJ [1 ]
机构
[1] Sungkyunkwan Univ, Sch Mech Engn, Suwon 440746, South Korea
关键词
condensation heat transfer; R-407C; R-22; POE oil; U-bend; microfin tube;
D O I
10.1016/S0017-9310(00)00253-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
Condensation heat transfer experiments for two refrigerants, R-407C and R-22, both mixed with polyol-ester (POE) and mineral oils were performed in straight and U-bend sections of a microfin tube. Experimental parameters included oil concentration (varied from 0% to 5%), mass flux (varied from 100 to 400 kg/m(2) s) and inlet quality (varied from 0.5 to 0.9). The enhancement factors (EFs) for both R-22 and R-407C refrigerants at the first straight section decreased continuously as the oil concentration increased. They decreased rapidly as mass flux decreased and inlet quality increased. The heat transfer coefficients had the maximum at the 90 degrees position of the U-bend. The heat transfer coefficients in the straight section after the U-bend, within a length 48 times that of the inner tube diameter, were larger by a maximum of 33% than the average beat transfer coefficient in the straight section before the U-bend. (C) 2001 Published by Elsevier Science Ltd.
引用
收藏
页码:2043 / 2051
页数:9
相关论文
共 50 条
  • [1] Evaporation heat transfer for R-22 and R-407C refrigerant-oil mixture in a microfin tube with a U-bend
    Cho, K
    Tae, SJ
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2000, 23 (03): : 219 - 231
  • [2] In-tube flow boiling of R-407C and R-407C/oil mixtures Part I: Microfin tube
    Zurcher, O
    Thome, JR
    Favrat, D
    HVAC&R RESEARCH, 1998, 4 (04): : 347 - 372
  • [3] In-tube flow boiling of R-407C and R-407C/oil mixtures. Part I: Microfin tube
    Zurcher, Olivier
    Thome, John R.
    Favrat, Daniel
    HVAC and R Research, 1998, 4 (04): : 347 - 372
  • [4] Effect of refrigeration oil on condensation heat transfer in microfin tube with U-bend
    Cho, K
    Tae, SJ
    HEAT TRANSFER SCIENCE AND TECHNOLOGY 2000, 2000, : 349 - 354
  • [5] Impact of refrigerant-oil solubility on an evaporator performances working with R-407C
    Youbi-Idrissi, M
    Bonjour, J
    Marvillet, C
    Meunier, F
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (03): : 284 - 292
  • [6] Two-phase flow heat transfer and friction characteristics of R-22 and R-407C
    Wang, CC
    Kuo, CS
    Chang, YJ
    Lu, DC
    ASHRAE TRANSACTIONS 1996, VOL 102, PT 1, 1996, 102 : 830 - 838
  • [7] Two-phase heat transfer characteristics for R-22/R-407C in a 6.5-mm smooth tube
    Wang, CC
    Chiang, CS
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 1997, 18 (06) : 550 - 558
  • [8] Two-phase flow heat transfer and friction characteristics of R-22 and R-407C
    Wang, Chi-Chuan
    Kuo, C.S.
    Chang, Yu-Juei
    Lu, D.C.
    ASHRAE Transactions, 1996, 102 (01): : 830 - 838
  • [9] Condensation Heat Transfer of R-407C in Helical Coiled Tube Heat Exchanger
    AlHajeri, Hamad Mohammad
    Almutairi, Abdulrahman
    Al-Hajeri, Mohamad Hamad
    Alenezi, Abdulrahman
    ALajmi, Rashed
    Koluib, Aboelyazeid Mohamed
    PROCESSES, 2020, 8 (09)
  • [10] Investigation of circumferential variation of heat transfer coefficients durina in-tube evaporation for R-22 and R-407C using liquid crystal
    Yoon, SH
    Kim, MS
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2002, 124 (05): : 845 - 853