Preliminary clinical results of photon energy recovery in simultaneous rest Tl-201/stress Tc-99m sestamibi myocardial SPECT

被引:3
作者
Hannequin, P
Weinmann, P
Mas, J
Vinot, S
机构
[1] Ctr Imagerie Nucl Annecy, F-74000 Annecy, France
[2] Hop Avicenne, Nucl Med Serv, F-93009 Bobigny, France
[3] Nucl Med Serv, Epinal, France
[4] SMVi, Buc, France
关键词
photon energy recovery; single photon emission computed tomography simultaneous dual-isotope imaging; technetium 99m sestamibi; thallium; 201;
D O I
10.1067/mnc.2001.111799
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The purpose of this study is to report the first clinical results obtained with the spectral deconvolution technique photon energy recovery (PER) for crosstalk correction in simultaneous rest thallium 201/stress technetium 99m sestamibi myocardial perfusion single photon emission computed tomography (SPECT), Methods and Results. Thirty-four patients with suspected coronary artery disease received Tl-201 (111-130 MBq) at rest, followed by single SPECT, Tc-99m sestamibi (444-518 MBq) mas then injected at stress, followed by dual SPECT. Single SPECT data were processed to obtain the following data sets: single raw (conventional) Tl-201 and single PER (scatter-corrected) T1-201, Dual SPECT data were professed to obtain the following data sets: dual raw Tl-201, dual PER (scatter- and crosstalk-corrected) T1-201, dual raw Tc-99m, and dual PER (scatter-corrected) Tc-99m, All. data sets were automatically analyzed with Cedars-Sinai Quantitative Perfusion SPECT software to derive the relative segmental uptake, the summed score, and the summed difference score. The relative segmental uptake, the summed score, and the number of patients with significant reversibility (summed difference score >2) were 74.84% +/- 12.79%, 3.44 +/- 3,07, and 13, respectively, for single raw Tk-201; 80.5% +/- 10.18%, 1.97 +/- 2,25, and 20, respectively, for dual raw Tl-201; 69.47% +/- 14.08%, 6.41 +/- 3,68, and 17, respectively, for single PER T1-201; and 69.99% +/- 13.39%, 6.58 +/- 3,63, and 17, respectively for dual PER T1-201, The differences between single and dual raw T1-201 data sets were highly significant, whereas there was no significant difference between PER-corrected Tl-201 data sets. Conclusions. PER is quantitatively efficient to correct for crosstalk in patients investigated with simultaneous rest Tl-201/stress Tc-99m sestamibi myocardial SPECT.
引用
收藏
页码:144 / 151
页数:8
相关论文
共 31 条
[1]   SEPARATE ACQUISITION REST THALLIUM-201/STRESS TC-99M SESTAMIBI DUAL-ISOTOPE MYOCARDIAL PERFUSION SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY - A CLINICAL VALIDATION-STUDY [J].
BERMAN, DS ;
KIAT, H ;
FRIEDMAN, JD ;
WANG, FP ;
VANTRAIN, K ;
MATZER, L ;
MADDAHI, J ;
GERMANO, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (05) :1455-1464
[2]   Comparative prognostic value of automatic quantitative analysis versus semiquantitative visual analysis of exercise myocardial perfusion single-photon emission computed tomography [J].
Berman, DS ;
Kang, XP ;
Van Train, KF ;
Lewin, HC ;
Cohen, I ;
Areeda, J ;
Friedman, JD ;
Germano, G ;
Shaw, LJ ;
Hachamovitch, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (07) :1987-1995
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Phantom evaluation of simultaneous thallium-201/technetium-99m aquisition in single-photon emission tomography [J].
Cao, ZJ ;
Chen, CC ;
Maunoury, C ;
Holder, LE ;
Abraham, TC ;
Tehan, A .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (11) :1514-1520
[5]  
DEPUEY EG, 1993, J NUCL MED, V11, P2006
[6]  
GERMANO G, 1995, J NUCL MED, V36, P2138
[7]  
Germano G, 2000, J NUCL MED, V41, P712
[8]   Exercise myocardial perfusion SPECT in patients without known coronary artery disease: Incremental prognostic value and use in risk stratification [J].
Hachamovitch, R ;
Berman, DS ;
Kiat, H ;
Cohen, I ;
Cabico, JA ;
Friedman, J ;
Diamond, GA .
CIRCULATION, 1996, 93 (05) :905-914
[9]  
Hachamovitch R, 1999, Cardiol Rev, V7, P83, DOI 10.1097/00045415-199903000-00011
[10]   SIMULTANEOUS DUAL-ISOTOPE TECHNETIUM-99M/THALLIUM-201 CARDIAC SPET IMAGING USING A PROJECTION-DEPENDENT SPILLDOWN CORRECTION FACTOR [J].
HADEMENOS, GJ ;
DAHLBOM, M ;
HOFFMAN, EJ .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1995, 22 (05) :465-472