Histomorphologic evaluation of Ti-13Nb-13Zr alloys processed via powder metallurgy.: A study in rabbits

被引:15
作者
Bottino, M. C. [2 ]
Coelho, P. G. [1 ]
Yoshimoto, M. [3 ]
Konig, B., Jr. [4 ]
Henriques, V. A. R. [5 ]
Bressiani, A. H. A. [3 ]
Bressiani, J. C. [3 ]
机构
[1] NYU, Coll Dent, Dept Biomat & Biomimet, Dubna 101000, Russia
[2] Univ Alabama, Dept Mat Sci & Engn, Birmingham, AL 35294 USA
[3] IPEN CNEN SP, Mat Sci & Technol Ctr, BR-05508000 Sao Paulo, Brazil
[4] Univ Sao Paulo, Dept Anat, Inst Biomed Sci, ICB, BR-05508900 Sao Paulo, Brazil
[5] CTA Brazilian Aerosp Tech Ctr, Div Mat, AMR IAE, BR-12228904 Sao Jose Dos Campos, Brazil
来源
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS | 2008年 / 28卷 / 02期
基金
巴西圣保罗研究基金会;
关键词
titanium alloys; osseointegration; biocompatibility; rabbits;
D O I
10.1016/j.msec.2006.12.014
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study presents the in-vivo evaluation of Ti-13Nb-13Zr alloy implants obtained by the hydride route via powder metallurgy. The cylindrical implants were processed at different sintering and holding times. The implants' were characterized for density, microstructure (SEM), crystalline phases (XRD), and bulk (EDS) and surface composition (XPS). The implants were then sterilized and surgically placed in the central region of the rabbit's tibiae. Two double fluorescent markers were applied at 2 and 3 weeks, and 6 and 7 weeks after implantation. After an 8-week healing period, the implants were retrieved, non-decalcified section processed, and evaluated by electron, UV light (fluorescent labeling), and light microscopy (toluidine blue). BSE-SEM showed close contact between bone and implants. Fluorescent labeling assessment showed high bone activity levels at regions close to the implant surface. Toluidine blue staining revealed regions comprising osteoblasts at regions of newly forming/formed bone close to the implant surface. The results obtained in this study support biocompatible and osseoconductive properties of Ti-13Nb-13Zr processed through the hydride powder route. (c) 2007 Published by Elsevier B.V.
引用
收藏
页码:223 / 227
页数:5
相关论文
共 17 条
[1]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[2]  
Coelho Paulo G., 2005, J. Appl. Oral Sci., V13, P87, DOI 10.1590/S1678-77572005000100018
[3]  
DAVIDSON JA, 1994, BIO-MED MATER ENG, V4, P231
[4]   A METHOD FOR THE STUDY OF UNDECALCIFIED BONES AND TEETH WITH ATTACHED SOFT-TISSUES - THE SAGE-SCHLIFF (SAWING AND GRINDING) TECHNIQUE [J].
DONATH, K ;
BREUNER, G .
JOURNAL OF ORAL PATHOLOGY & MEDICINE, 1982, 11 (04) :318-326
[5]  
Garetto L P, 1995, Implant Dent, V4, P235, DOI 10.1097/00008505-199500440-00002
[6]   HISTOLOGICAL RESPONSE TO CYLINDERS OF A LOW MODULUS TITANIUM-ALLOY (TI-13NB-13ZR) AND A WEAR-RESISTANT ZIRCONIUM ALLOY (ZR-2.5NB) IMPLANTED IN THE RABBIT TIBIA [J].
GOODMAN, SB ;
DAVIDSON, JA ;
FORNASIER, VL ;
MISHRA, AK .
JOURNAL OF APPLIED BIOMATERIALS, 1993, 4 (04) :331-339
[7]   Enhanced bone integration of implants with increased surface roughness:: a long term study in the sheep [J].
Grizon, F ;
Aguado, E ;
Huré, G ;
Baslé, MF ;
Chappard, D .
JOURNAL OF DENTISTRY, 2002, 30 (5-6) :195-203
[8]  
Hench LL, 1998, J AM CERAM SOC, V81, P1705
[9]   Pore diameter of more than 100 μm is not requisite for bone ingrowth in rabbits [J].
Itälä, AI ;
Ylänen, HO ;
Ekholm, C ;
Karlsson, KH ;
Aro, HT .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 58 (06) :679-683
[10]   Design and mechanical properties of new β type titanium alloys for implant materials [J].
Kuroda, D ;
Niinomi, M ;
Morinaga, M ;
Kato, Y ;
Yashiro, T .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1998, 243 (1-2) :244-249