Study of Detection Deficiency of 3D Position-Sensitive Pixellated CdZnTe Detectors

被引:0
作者
Xu, Dan [1 ]
He, Zhong [1 ]
Zhang, Feng [1 ]
机构
[1] Univ Michigan, Nucl Engn & Radiol Sci Dept, Ann Arbor, MI 48109 USA
来源
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6 | 2006年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Three dimensional position-sensitive Cadmium Zinc Telluride (CdZnTe) detectors can provide positions and corresponding energy depositions of each individual gamma-ray interaction within the detector. For single-interaction events, the interaction depth is obtained by calculating the cathode to anode ratio. For multi-interaction events, the individual interaction depth is obtained by measuring the timing difference between the cathode and anode signals. It had been observed that some of the measured events were lost during the event reconstruction process. It was discovered recently that the discrepancy on total efficiency is due to the triggering threshold of the system, because some interactions cannot trigger the cathode or the anode readout channel. As a result, the detection efficiency is lowered for multi-interaction events if timing trigger is always required on all channels. In this study, we analyze the effect of triggering threshold on the detection efficiency, and present a method of recovering events lacking certain timing triggers.
引用
收藏
页码:3651 / 3655
页数:5
相关论文
共 50 条
[41]   Gap measurement by position-sensitive detectors [J].
Kim, JK ;
Kim, MS ;
Bae, JH ;
Kwon, JH ;
Lee, HB ;
Jeong, SH .
APPLIED OPTICS, 2000, 39 (16) :2584-2591
[42]   MULTIPURPOSE ARRAY OF POSITION-SENSITIVE DETECTORS [J].
OBST, AW ;
BRAITHWA.WJ ;
DOSS, CR .
BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (04) :528-528
[43]   Gap measurement by position-sensitive detectors [J].
Kim, Jung-Ki ;
Kim, Man-Suhk ;
Bae, Jong Han ;
Kwon, Jin Hyuk ;
Lee, Hang-Boo ;
Jeong, Soo-Hoa .
Applied Optics, 2000, 39 (16) :2584-2591
[44]   POSITION-SENSITIVE SEMICONDUCTOR-DETECTORS [J].
LAEGSGAARD, E .
NUCLEAR INSTRUMENTS & METHODS, 1979, 162 (1-3) :93-111
[45]   FAST TIMING POSITION-SENSITIVE DETECTORS [J].
KLEIN, C ;
TROTSCHER, J ;
WOLLNIK, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 335 (1-2) :146-147
[46]   Noise analysis for position-sensitive detectors [J].
Narayanan, C ;
Buckman, AB ;
Busch-Vishniac, I .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1997, 46 (05) :1137-1144
[47]   EPITAXIAL SILICON POSITION-SENSITIVE DETECTORS [J].
SHIRAISHI, F ;
KIM, C ;
KIM, H ;
KIKUCHI, K ;
HUSIMI, K ;
OHKAWA, S .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (01) :554-557
[48]   POSITION-SENSITIVE DETECTORS AND WEISSENBERG DIFFRACTOMETERS [J].
PRINCE, E ;
SANTORO, A .
ACTA CRYSTALLOGRAPHICA SECTION A, 1975, 31 :S234-S234
[49]   DEVELOPMENT OF POSITION-SENSITIVE SCINTILLATION DETECTORS [J].
ROGERS, EH ;
WHITESID.H ;
ARENS, JF .
BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (04) :455-455
[50]   DIGITAL PROCESSOR FOR POSITION-SENSITIVE DETECTORS [J].
FISCHER, BE .
NUCLEAR INSTRUMENTS & METHODS, 1977, 141 (01) :173-181