Study of Detection Deficiency of 3D Position-Sensitive Pixellated CdZnTe Detectors

被引:0
|
作者
Xu, Dan [1 ]
He, Zhong [1 ]
Zhang, Feng [1 ]
机构
[1] Univ Michigan, Nucl Engn & Radiol Sci Dept, Ann Arbor, MI 48109 USA
来源
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6 | 2006年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Three dimensional position-sensitive Cadmium Zinc Telluride (CdZnTe) detectors can provide positions and corresponding energy depositions of each individual gamma-ray interaction within the detector. For single-interaction events, the interaction depth is obtained by calculating the cathode to anode ratio. For multi-interaction events, the individual interaction depth is obtained by measuring the timing difference between the cathode and anode signals. It had been observed that some of the measured events were lost during the event reconstruction process. It was discovered recently that the discrepancy on total efficiency is due to the triggering threshold of the system, because some interactions cannot trigger the cathode or the anode readout channel. As a result, the detection efficiency is lowered for multi-interaction events if timing trigger is always required on all channels. In this study, we analyze the effect of triggering threshold on the detection efficiency, and present a method of recovering events lacking certain timing triggers.
引用
收藏
页码:3651 / 3655
页数:5
相关论文
共 50 条
  • [31] Measurements of Gamma Rays above 3 MeV using 3D Position-Sensitive 20x20x15 mm3 CdZnTe Detectors
    Boucher, Yvan A.
    Zhang, Feng
    Kaye, Willy
    He, Zhong
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4540 - 4544
  • [32] High-energy 3D calorimeter for use in gamma-ray astronomy based on position-sensitive virtual Frisch-grid CdZnTe detectors
    Moiseev, A.
    Bolotnikov, A.
    DeGeronimo, G.
    Hays, E.
    James, R.
    Thompson, D.
    Vernon, E.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [33] FRAM v5.2 estimation of plutonium and uranium isotopics using digitized 3-D position-sensitive CdZnTe detectors
    Goodman, David
    Xia, Jiawei
    Sanders, Jeff
    He, Zhong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 954
  • [34] PIXELLATED CSI(TL) ARRAYS WITH POSITION-SENSITIVE PMT READOUT
    TRUMAN, A
    BIRD, AJ
    RAMSDEN, D
    HE, Z
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3): : 375 - 378
  • [35] Artifacts in High-Energy Compton Imaging With 3-D Position-Sensitive CdZnTe
    Shy, Daniel
    Xia, Jiawei
    He, Zhong
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2020, 67 (08) : 1920 - 1928
  • [36] EFFICIENCY OF BE-8 DETECTION USING POSITION-SENSITIVE DETECTORS
    MENCHACAROCHA, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1975, 22 (04) : 1997 - 2000
  • [37] Performance Improvement of 3-D Position-Sensitive Pixellated HgI2 Detectors when Cooled from Room Temperature to 10 °C
    Zhu, Yuefeng
    Kaye, Willy
    He, Zhong
    Zhang, Feng
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3959 - 3962
  • [38] A STUDY OF THE TRANSIENT-RESPONSE OF POSITION-SENSITIVE DETECTORS
    DUTTA, AK
    HATANAKA, Y
    SOLID-STATE ELECTRONICS, 1989, 32 (06) : 485 - 492
  • [39] Benefits of Position-Sensitive Detectors for Source Detection with Known Background
    Lingenfelter, Daniel J.
    Fessler, Jeffrey A.
    Scott, Clayton D.
    He, Zhong
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 636 - 640
  • [40] Gap measurement by position-sensitive detectors
    Kim, JK
    Kim, MS
    Bae, JH
    Kwon, JH
    Lee, HB
    Jeong, SH
    APPLIED OPTICS, 2000, 39 (16) : 2584 - 2591