摘要
Three dimensional position-sensitive Cadmium Zinc Telluride (CdZnTe) detectors can provide positions and corresponding energy depositions of each individual gamma-ray interaction within the detector. For single-interaction events, the interaction depth is obtained by calculating the cathode to anode ratio. For multi-interaction events, the individual interaction depth is obtained by measuring the timing difference between the cathode and anode signals. It had been observed that some of the measured events were lost during the event reconstruction process. It was discovered recently that the discrepancy on total efficiency is due to the triggering threshold of the system, because some interactions cannot trigger the cathode or the anode readout channel. As a result, the detection efficiency is lowered for multi-interaction events if timing trigger is always required on all channels. In this study, we analyze the effect of triggering threshold on the detection efficiency, and present a method of recovering events lacking certain timing triggers.
引用
收藏
页码:3651 / 3655
页数:5
相关论文
共 50 条
  • [21] 1-D Fast Neutron Source Localization Using Digital Pixelated 3-D Position-Sensitive CdZnTe Detectors
    Goodman, David
    Streicher, Michael
    Zhu, Yuefeng
    Brown, Steven
    He, Zhong
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2017, 64 (09) : 2531 - 2535
  • [22] High Resolution Time-Encoded Imaging of Plutonium and MOX using 3-D Position-Sensitive CdZnTe Detectors
    Goodman, David
    Xia, Jiawei
    Brown, Steven
    Chichester, David L.
    He, Zhong
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [23] Benefits of Position-Sensitive Detectors for Radioactive Source Detection
    Lingenfelter, Daniel J.
    Fessler, Jeffrey A.
    Scott, Clayton D.
    He, Zhong
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2010, 58 (09) : 4473 - 4483
  • [24] Detection of gamma ray polarization using a 3D position sensitive CdZnTe detector
    Xu, D
    He, Z
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 376 - 380
  • [25] Position-sensitive superconductor detectors
    Kurakado, M.
    Taniguchi, K.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [26] POSITION-SENSITIVE PHOSWICH DETECTORS
    CHAN, Y
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 54 - NUCL
  • [27] POSITION-SENSITIVE GERMANIUM DETECTORS
    PROTIC, D
    RIEPE, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (01) : 553 - 555
  • [28] POSITION-SENSITIVE SCINTILLATION DETECTORS
    ROGERS, EH
    ARENS, JF
    WHITESIDE, H
    NUCLEAR INSTRUMENTS & METHODS, 1974, 121 (03): : 599 - 604
  • [29] SEMICONDUCTOR POSITION-SENSITIVE DETECTORS
    RADEKA, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 226 (01): : 209 - 218
  • [30] Improved resolution for 3D position sensitive CdZnTe spectrometers
    Zhang, F
    He, Z
    Xu, D
    Knoll, GF
    Wehe, DK
    Berry, JE
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3356 - 3360