Low temperature durability and consistency analysis of proton exchange membrane fuel cell stack based on comprehensive characterizations

被引:82
作者
Zhong, Di [1 ]
Lin, Rui [1 ]
Jiang, Zhenghua [1 ]
Zhu, Yike [1 ]
Liu, Dengchen [1 ]
Cai, Xin [1 ]
Chen, Liang [1 ]
机构
[1] Tongji Univ, Sch Automot Studies, Shanghai 201804, Peoples R China
基金
中国国家自然科学基金;
关键词
PEMFC stack; Low temperature; Durability; Consistency; 3D imaging reconstruction; COLD START; PERFORMANCE; DEGRADATION; STRATEGY; UNIFORMITY; PEMFCS; MEA;
D O I
10.1016/j.apenergy.2020.114626
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The cold start is one of the key research fields in proton exchange membrane fuel cell investigation. In this work, a low temperature durability and consistency analysis is performed on a 5-cells stack. After 20 times freezing and thaw cycles, coefficient of variation of individual cell voltage increase significantly. Through the polarization curve test, it is found that the output performance degradation of each individual cell is inconsistent. The No.1 cell which is the nearest from the gas inlets has the maximum performance degradation. Through electro-chemical impedance spectroscopy, cyclic voltammetry, scanning electron microscope, segmented current density test and synchrotron radiation X-ray scan 3D image reconstruction, the cracks on the interface of membrane and catalyst layer are observed in situ successfully for the first time. Under the condition in this work, the water content of No.1 cell is the most, and a lot amount of water is frozen at the air inlet area. Due to the frost heave stress, the structure of membrane electrode assembly is damaged. This causes the loss and the agglomeration of catalyst, and even the delamination of catalyst layer. The above structure changes cause a decrease in catalyst activity and an increase in cell resistance, and eventually lead to the inconsistent degradation in output performance. The characterization results in this work are helpful for the optimization and application of membrane electrodes assembly and stacks for vehicle fuel cells.
引用
收藏
页数:13
相关论文
共 28 条
[1]   A Comprehensive Review of Solutions and Strategies for Cold Start of Automotive Proton Exchange Membrane Fuel Cells [J].
Amamou, Ali Akrem ;
Kelouwani, Sousso ;
Boulon, Loic ;
Agbossou, Kodjo .
IEEE ACCESS, 2016, 4 :4989-5002
[2]   Humidity and Temperature Cycling Effects on Cracks and Delaminations in PEMFCs [J].
Banan, R. ;
Zu, J. ;
Bazylak, A. .
FUEL CELLS, 2015, 15 (02) :327-336
[3]  
Chamagne D, 2017, CNAM, P1, DOI [10.1002/fuce.201700112, DOI 10.1002/FUCE.201700112]
[4]   Electrocatalyst approaches and challenges for automotive fuel cells [J].
Debe, Mark K. .
NATURE, 2012, 486 (7401) :43-51
[5]   Maximum power cold start mode of proton exchange membrane fuel cell [J].
Du, Qing ;
Jia, Bin ;
Luo, Yueqi ;
Chen, Jixin ;
Zhou, Yibo ;
Jiao, Kui .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (16) :8390-8400
[6]   Current Ramping: A Strategy for Rapid Start-up of PEMFCs from Subfreezing Environment [J].
Jiang, Fangming ;
Wang, Chao-Yang ;
Chen, Ken S. .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2010, 157 (03) :B342-B347
[7]   Crack Formation in Membrane Electrode Assembly Under Static and Cyclic Loadings [J].
Kai, Yusuke ;
Kitayama, Yuki ;
Omiya, Masaki ;
Uchiyama, Tomoaki ;
Kato, Manabu .
JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY, 2013, 10 (02)
[8]   Performance evaluation of a PEM fuel cell stack with variable inlet flows under simulated driving cycle conditions [J].
Kurnia, Jundika C. ;
Sasmito, Agus P. ;
Shamim, Tariq .
APPLIED ENERGY, 2017, 206 :751-764
[9]   Experimental study on the voltage uniformity for dynamic loading of a PEM fuel cell stack [J].
Li, Yankun ;
Zhao, Xingqiang ;
Liu, Zhixiang ;
Li, Yan ;
Chen, Weirong ;
Li, Qi .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2015, 40 (23) :7361-7369
[10]   Approaches to avoid flooding in association with pressure drop in proton exchange membrane fuel cells [J].
Li, Yuehua ;
Pei, Pucheng ;
Wu, Ziyao ;
Ren, Peng ;
Jia, Xiaoning ;
Chen, Dongfang ;
Huang, Shangwei .
APPLIED ENERGY, 2018, 224 :42-51