Interocular asymmetry of the superonasal retinal nerve fibre layer thickness and blood vessel diameter in healthy subjects

被引:6
|
作者
Ly, Angelica [1 ,2 ]
Banh, Jennifer [2 ]
Luu, Patricia [2 ]
Huang, Jessie [1 ,2 ]
Yapp, Michael [1 ,2 ]
Zangerl, Barbara [1 ,2 ]
机构
[1] Ctr Eye Hlth, Sydney, NSW, Australia
[2] Univ New South Wales, Sch Optometry & Vis Sci, Sydney, NSW, Australia
来源
PLOS ONE | 2019年 / 14卷 / 12期
基金
澳大利亚国家健康与医学研究理事会; 英国医学研究理事会;
关键词
PARAMETERS; SYMMETRY; GLAUCOMA; EYES;
D O I
10.1371/journal.pone.0226728
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Optical coherence tomography is commonly used to measure the retinal nerve fibre layer thickness in both normal and diseased eyes; however, variation among normal eyes is common and may limit the usefulness of the results. The aim of this study was to explore the interocular asymmetries in retinal nerve fibre layer thickness in a group of normal eyes and to investigate the influence of blood vessel diameter on local retinal nerve fibre layer thickness. Methods In this prospective study, retinal nerve fibre layer thickness and blood vessel diameter across 100 healthy participants were measured using two optical coherence tomography instruments. Individuals were categorised into two groups based on the presence or absence of interocular retinal nerve fibre layer thickness asymmetry beyond the 75th percentile of all participants. Results The superonasal sectoral retinal nerve fibre layer thickness was significantly greater in the left eye compared to the right, across all three sectors. Mean blood vessel diameter showed a corresponding difference in thickness at one of the superonasal sectors. Linear regression showed a positive and moderate correlation between blood vessel diameter and focal retinal nerve fibre layer thickness. This trend persisted across both arteries and veins, but veins showed larger variability between left and right eye in participants with marked superonasal retinal nerve fibre layer asymmetry. Conclusion Retinal nerve fibre layer thickness and blood vessel diameter vary significantly between eyes even in healthy individuals. These asymmetries in a normal population should be taken into consideration when interpreting the retinal nerve fibre layer thickness measurements from optical coherence tomography to assist in distinguishing normal variations from disease.
引用
收藏
页数:14
相关论文
共 50 条
  • [11] Evaluation of Interocular Retinal Nerve Fiber Layer Thickness Symmetry as a Diagnostic Modality for Glaucoma
    Hong, Seung Woo
    Lee, Seung Bum
    Jee, Dong-hyun
    Ahn, Myung Douk
    JOURNAL OF GLAUCOMA, 2016, 25 (09) : E763 - E771
  • [12] Vessel density and retinal nerve fibre layer thickness following acute primary angle closure
    Moghimi, Sasan
    SafiZadeh, Mona
    Xu, Benjamin Y.
    Fard, Masoud Aghsaei
    Khatibi, Nassim
    Rao, Harsha Laxmana
    Weinreb, Robert N.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (08) : 1103 - 1108
  • [13] Histological measurement of retinal nerve fibre layer thickness
    S Frenkel
    J E Morgan
    E Z Blumenthal
    Eye, 2005, 19 : 491 - 498
  • [14] Histological measurement of retinal nerve fibre layer thickness
    Frenkel, S
    Morgan, JE
    Blumenthal, EZ
    EYE, 2005, 19 (05) : 491 - 498
  • [15] Multivariate Model of the Intersubject Variability of the Retinal Nerve Fiber Layer Thickness in Healthy Subjects
    Pereira, Ivania
    Resch, Hemma
    Schwarzhans, Florian
    Wu, Jing
    Holzer, Stephan
    Kiss, Barbara
    Frommlet, Florian
    Fischer, Georg
    Vass, Clemens
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (09) : 5290 - 5298
  • [16] Retinal nerve fiber layer thickness and peripapillary retinal blood flow in glaucoma and healthy volunteers
    Kuba, GB
    Pillunat, LE
    Böhm, AG
    Klemm, M
    OPHTHALMOLOGE, 2001, 98 (01): : 41 - 46
  • [17] Central corneal thickness and retinal nerve fiber layer thickness in ocular hypertensive patients and healthy subjects
    Arnavielle, S.
    Muselier, A.
    Creuzot-Garcher, C.
    Bron, A.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2009, 32 (06): : 383 - 389
  • [18] Correlation between retinal nerve fibre layer thickness and retinal sensitivity
    Sato, Shino
    Hirooka, Kazuyuki
    Baba, Tetsuya
    Yano, Izumi
    Shiraga, Fumio
    ACTA OPHTHALMOLOGICA, 2008, 86 (06) : 609 - 613
  • [19] Norms of Interocular Circumpapillary Retinal Nerve Fiber Layer Thickness Differences at 768 Retinal Locations
    Baniasadi, Neda
    Rauscher, Franziska G.
    Li, Dian
    Wang, Mengyu
    Choi, Eun Young
    Wang, Hui
    Peschel, Thomas
    Wirkner, Kerstin
    Kirsten, Toralf
    Thiery, Joachim
    Engel, Christoph
    Loeffler, Markus
    Elze, Tobias
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2020, 9 (09): : 1 - 11
  • [20] Thinner retinal nerve fibre layer in healthy myopic eyes with thinner central corneal thickness
    Arranz-Marquez, Esther
    Lauzirika, Gorka
    Teus, Miguel A.
    Katsanos, Andreas
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (11) : 2477 - 2481