Practical guide to monitoring anaesthetised small animal patients

被引:3
作者
Mathis, Alessandra [1 ]
机构
[1] Willows Referral Serv, Shirley, W Midlands, England
关键词
BLOOD-PRESSURE; CATS; DOGS; DEVICES; VALUES;
D O I
10.1136/inp.i3947
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Anaesthesia - a reversible and controlled coma-like state - is an art based on an understanding of many contributing factors: pharmacology, the patient and its varied physiological processes or disease states, the procedure being undertaken and the potential complications arising as a result of all of these. Monitoring a patient at this time can be challenging but the increasing use of multiparameter monitors reduces the incidence of morbidity and mortality in both people and animals. Understanding the data displayed on these monitors is important, but it is vital not to lose sight of the whole picture as well. This article focuses on the main parameters that are monitored when small animals undergo general anaesthesia (including the patient itself) and explains how the data acquired should be considered in relation to other information.
引用
收藏
页码:363 / 372
页数:9
相关论文
共 10 条
  • [1] Risk factors for anaesthetic-related death in cats: results from the confidential enquiry into perioperative small animal fatalities (CEPSAF)
    Brodbelt, D. C.
    Pfeiffer, D. U.
    Young, L. E.
    Wood, J. L. N.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2007, 99 (05) : 617 - 623
  • [2] A comparison of indirect blood pressure monitoring techniques in the anesthetized cat
    Caulkett, NA
    Cantwell, SL
    Houston, DM
    [J]. VETERINARY SURGERY, 1998, 27 (04) : 370 - 377
  • [3] Measuring level of agreement between values obtained by directly measured blood pressure and ultrasonic Doppler flow detector in cats
    da Cunha, Anderson F.
    Saile, Katrin
    Beaufrere, Hugues
    Wolfson, Wendy
    Seaton, Diana
    Acierno, Mark J.
    [J]. JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2014, 24 (03) : 272 - 278
  • [4] Haberman CE, 2006, CAN J VET RES, V70, P211
  • [5] Keenan R L, 1991, J Clin Anesth, V3, P433, DOI 10.1016/0952-8180(91)90088-5
  • [6] Comparison of high-definition oscillometry - a non-invasive technology for arterial blood pressure measurement - with a direct invasive method using radio-telemetry in awake healthy cats
    Martel, Eric
    Egner, Beate
    Brown, Scott A.
    King, Jonathan N.
    Laveissiere, Arnaud
    Champeroux, Pascal
    Richard, Serge
    [J]. JOURNAL OF FELINE MEDICINE AND SURGERY, 2013, 15 (12) : 1104 - 1113
  • [7] Moens YPS, 1994, J VET ANAESTHESIA, V21, P94
  • [8] Comparison of high definition oscillometric and Doppler ultrasonic devices for measuring blood pressure in anaesthetised cats
    Petric, Aleksandra Domanjko
    Petra, Zrimsek
    Jerneja, Sredensek
    Alenka, Seliskar
    [J]. JOURNAL OF FELINE MEDICINE AND SURGERY, 2010, 12 (10) : 731 - 737
  • [9] Normal values and incidence of cardiorespiratory complications in dogs during general anaesthesia.: A review of 1281 cases
    Redondo, J. I.
    Rubio, M.
    Soler, G.
    Serra, I.
    Soler, C.
    Gomez-Villamandos, R. J.
    [J]. JOURNAL OF VETERINARY MEDICINE SERIES A-PHYSIOLOGY PATHOLOGY CLINICAL MEDICINE, 2007, 54 (09): : 470 - 477
  • [10] Comparison of high definition oscillometric and Doppler ultrasound devices with invasive blood pressure in anaesthetized dogs
    Seliskar, Alenka
    Zrimsek, Petra
    Sredensek, Jerneja
    Petric, Aleksandra D.
    [J]. VETERINARY ANAESTHESIA AND ANALGESIA, 2013, 40 (01) : 21 - 27